Gaschromatographs

Shimadzu GC-2014 GC with FID

Preis auf Anfrage
ID-number: 14057
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
Shimadzu's gas chromatography system offers high performance and expandability to a higher level. With our improved design and innovative technology for all of our injectors, detectors and flow controllers, we offer the same or better performance as our GC-2010, the high-end technology leader. Operation is easy thanks to the large LCD and fully digital gas control and automatic diagnostics adopted from the GC-2010 - the most advanced and easiest to use interface. You have the flexibility to use any column type for any analysis. Packed or capillary columns allow you to choose the best technique for your measurement. Fully integrated multi-valve systems are easy to use and enable optimal performance for customized SystemGC GC products. The temperature range of the column oven is from (ambient temperature + 10°C) to 400°C (with liquid CO2 gas: -50°C ~ 400°C). The dimensions are 250 (W) × 360 (H) × 175 (D) mm and the oven capacity is 15.8 liters. In the sample injection unit, the temperature can be set up to 400°C and up to three units can be installed at the same time. The carrier gas flow controller has a flow range of 0 ~ 100mL/min for packed/dual samples and keeps the column flow constant during column oven heating. For capillary split/splitless direct injections there is a pressure range of 0 ~ 970kPa. The system includes various detectors whose temperature range extends up to 400°C depending on the model and which can be adjusted in increments of 1°C. Up to four units can be installed at the same time. The Flame Ionization Detector (FID) has a temperature range of up to 400°C and a minimum detection quantity of 3pgC/s (dodecane). The thermal conductivity detector (TCD) also has a temperature range up to 400°C and a sensitivity of 40,000mV · mL/mg. In addition, there are other detectors such as the Flame Photometric Detector (FPD) and the Flame Thermion Detector (FTD), each with their own specifications and temperature ranges. Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00014057
ID-number 14057
Object name Shimadzu GC-2014 GC with FID
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture SHIMADZU
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: GC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure