Gaschromatographs

Shimadzu GC-2014 GC (SPL) with SFID and PID

Preis auf Anfrage
ID-number: 14054
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
The Shimadzu gas chromatograph system combines high performance and expandability at a higher level. Thanks to improved design and innovative technology, it surpasses our previous top model, the GC-2010, in terms of injectors, detectors and flow controllers. It is also very easy to operate thanks to a large LCD, digital gas control and auto-diagnosis. It expands your flexibility thanks to the ability to use any type of column for any analysis, coupled with fully integrated multi-valve systems. This Shimadzu GC-2014 GC with SFID and PID is in excellent condition and includes an injection unit DINJ-W14, DFID, DTCD and DAFC. It also includes a 7-port valve and 10-port valve, as well as a column cooling oven option. We have specialist knowledge of analytical devices. Specifications: . - Column oven: Temperature range: (ambient + 10°C) ~ 400°C (with liquid CO² gas: -50°C ~ 400°C). Dimensions: 250 (W) × 360 (H) × 175 (D) mm. Oven capacity: 15. 8L. Temperature Accuracy: Accurate to ±1%. Temperature deviation: Maximum 2°C. Temperature variation: 0. 01°C/°C. Programmed steps: Up to 20. Programmable setting range: -250°C ~ 250°C/min. Total time of all steps: 9999. 99 min max. Linear heating range: 30°C/min to 150°C, 20°C/min to 250°C, 10°C/min to 380°C, 7°C/min to 400 °C. Cooling rates: 300°C ~ 50°C in 6 min max. - Sample injection unit: temperature range up to 400°C. Heating levels adjustable in 1°C increments. Installation of up to 3 units possible at the same time. - Carrier gas flow controller: For packed/double gas: Flow rate adjustment range: 0~100mL/min. Programmable setting range: 400 ~ 400mL/min. Correction function: Maintaining the column flow rate while the column oven is heating. - Detectors: temperature range up to 400°C. Temperature set in 1°C increments. Installation of up to 4 units possible at the same time. The system also contains various detectors such as: B. a Flame Ionization Detector (FID), a Thermal Conductivity Detector (TCD), a Flame Photometric Detector (FPD) and a Flame Thermion Detector (FTD). Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00014054
ID-number 14054
Object name Shimadzu GC-2014 GC (SPL) with SFID and PID
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture SHIMADZU
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: GC