Archive

Shimadzu AA 6800

ID-number: 014619
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Shimadzu AAS AA-6800. With Flame. Graphite tube GFA 6500. Autosampler ASC 6100. Software. PC. YoC 2001. Regulare servicing. All lamps available at inquiry.
siehe Storeview
More Information
Objektnummer B00014619
ID-number 014619
Object name Shimadzu AA 6800
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Shimadzu

Modell:                AA 6800

Kommentar:        Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

The Atomic Absorption Spectrophotometer AA-6800 incorporates two background correction functions, the D2 method (Deuterium Lamp method) and the SR method (Self-Reversal method), enabling selection of the appropriate method for the measurement sample.

The AA-6800 allows you to change the measurement mode while automatically switching the atomizer, thus enabling quick and easy switching back and forth between flame measurement and furnace measurement. In addition, wide ranging measurement operations are available, from manual Operation to automatic continuous measurement of multi-elements wich the use of an autosampler (ASC-6100). This enables selection of the appropriate combination to match the number of elements and samples to be analyzed as well as the skill of the operator.

The PC software controlline, the AA-6800 operates an the MS-Windows", and using the Wizard for parameter setting enables an operator, even an beginner of atomic absorption spectrophotometer, to make measurement conditions easily.

The GFA-6500 is the graphite furnace atomizer adopted for use with the Atomic Absorption Spectrophotometer AA-6800. With the graphite furnace connected to the Instrument, quantitative analysis of elements may be conducted using the furnace method. Following is a description of GFA-6500 features.

(1) With the incorporated high sensitivity optical-thermal sensor and the automatic temperature correction function employing current control regions, simple temperature correction and accurate temperature repeatability are achieved.

(2) Temperature control via the optical-thermal sensor is conducted from 400°C, thus making possible accurate temperature control from anhing to atomization.

(3) At sample atomization, use of the high sensitivity mode allows trace analysis of even greater sensitivity and higher precision than previously possible with live of Instruments.

(4) Precise inner gas current control is possible at each heating stage and automatic switching of the gas type allows composition of flexible temperature programs. These features make the GFA-6500 extremely effective in analyzing a wide variety of sample typen.

AA-6800F/6800G Common Specifications

Spectro

photometer

Measurement Wavelength Range

190~900nm

Mounitng

Aberration-corrected Czerny-Turner mount

Bandwidth

0.1, 0.2, 0.5, 2.0, 5.0 nm (6-step automatic switching)

Lamp

Number of Lamp Sockels

Photometrie Method

8 lamp sockets, 2 lamps simultanously lit (1 for warming up)

High-speed seif reversal method (BGC-SR)

High-speed 2-frequency simultanous measurement (BGC-D2)

Lamp Mode

EMISSION, NON-BGC, BGC-SR, BGC-D2, D2

Data Processing

Software Environment

Parameter Setting

MS-Windows TM 95

Wizard Method

Measurement Mode

Flame continuous method, Fumace method

Concentration Conversion Mode

Repeat Measurement

•Calibration Curve (selectable arnong 1st, 2nd, 3rd order function)

•Standard addition method/Simple Standard addition method (1st order function)

•Max. 10 repetitions

•Indication of Average, Standard deviation (SD) and Relative Standard Deviation (RSD)

•Exclusion of deviant value based an SD value and RSD value

Baseline Correction

Automatic baseline dritt correction using electrical double beam Signal processing (Furnace)

Sensitivity Correction

Automatic calibration curve correction System by sensitivity observation.

Table Data Processing Functions

Multitask

Actual concentration calculation using Weight factor, Dilution factor, Volume factor and Correction factor.

Word processor Software or the like can be used while executing measurement.

Loading Parameters

Template function

Procedure/Result Display

MRT Work Sheet (MRT: Measurement Result Table)

Result Print

Summary Report

QA/QC

Correlation factor, LCS, SPK, Sample upper limt, %RSD

Power Requirements

Dimensions, Weight

AC100, 120, 220, 230, 240V switching incorporated, 600VA, 50/60Hz

Additional power for personal Computer is necessary‑

W 1080 X D550 X H460mm, 100kg (including gas controller. not including PC)

Ambient Temperature Range

10°C ~ 35C

Ambient Hurt udity Range

45% ~ 80% (less than 70% if temperature is over 30°C)

AA-6800F Specifications

Burner Unit

Type

Air-cooled pre-mix type

Bunter Head

Pure Titanium

Nebulizer

Pt-Ir capillary with Teflon orifice,

Impact bead is inseparable. Fluoric acid is usable.

Chamber

Polypropylene

Positioning

Bumer/Fumace automatic switching by motor drive

Automatic searching for optimum burner height

Gas Controller

Flow Rate/Pressure Control

Automatic flow rate settin-,

Automatic searching for optimum gas flow rate

Safety Measures

•Automatic gas leak check     • Air-C 2 H 2 flame priority ignition

•Air/N 2 0 auto switching with C 2 H 2 flow rate monitor (optical Sensor)

•Prevents raw gas discharge             • Prevents usage of wrong burner head

•Pressure monitor to prevent flashback at abnormal pressure

•Safety extinction by automatic detection of momentary power failure

•Drain tank water level monitor to prevent flashback

AA-680OG Specifications (GFA-6500 Specifications)

Heating Temperature Range

Ambient~3000 °C

Heating Control Method

•Drying: Current control method

•Ashing/Atomizing: Optical temperature control method

Heating Parameter settings

•Max. 20 stages           • Heating mode: RAMP/STEP

•Inner gas type: 2-line switching         • High sensitivity setting

•Furnace concentration boost cycle: Max 20 times

•Innen gas flow rate: 0~1.5 L/min

•Optimum fumace program search function

Cooling water/Ar Consumption

Power Requirements

•Cooling water: 1.0 L/min or larger     • Gas: Max. 3.0 L/min

•AC200V Max.6kVA, 50/60Hz

Power Supply Unit, Dimension and Weight

•W42XD29XH460 (innt). 442 (Power supp1.v unit fins in space behmd 14 mit unit. Main unit width on1.v needs to be considered.)

Optional

ASC-6100

By connecting to the Shimadzu Atomic Absorption Spectrophotometer, the ASC-6100 per­forms the functions as the autosampler for flame absorption measurement. Also, when G attach­ment ASK-6100 is mounted, the ASC-6100 can perform a wide variety of following functions automatically in the furnace quantitative measurement by linking wich the Shimadzu Atomic Absorption Spectrophotometer main unit.

(1) Sample dilution

(2) Reagent addition

(3) Mixture of samples and reagents at the mixing port

(4) Combined rinsing of mixing port

(5) Automatic dilution and re-analysis for off-scale measurements due to excessive concentra­tion of unknown samples

(Dilution rate is automatically set. Possible dilution rate is 300 times at maximum.)

(6) Injection of high accuracy sample. Sampling amount can be changed in the unit of 1µl.

(7) Booting of sample concentration in Fumace measurement

For Flame and Furnace

Control

By RS-232C with AA

Function

Origin search

Self diagnosis

Automatic rinsing

Automatic preparation

Random access

Number of sample

8 for Reagent

60 for Sample

(random access available for both)

Sample cup

Sample : 15ml (testing tube for Flame) or 2ml (vial for Furnace)

Reagent : 20ml

Rinne nozzle

Discharge rinsie liquid from nozzle (for Furnace)

Intake rinse liquid from nozzle (for Flame)

Bottle for rinse liquid

2l

Power

AC100V ~ 240V (auto sensing), 100VA

Dimension • Weight

For Flame : W330 x H320 x D295mm. 7.5kg

For Flame and Furnace : W430 x H320 x D360mm, 15kg

For Furnace only

Function

Automatic dilution

Automatic reagent addition

Syringe

250µl

Injection volume

2 --100µl

Reproducibility

1% R.S.D (20µl)

Cary over

Rinsing port :under 0.00001

Mixing port :under 0.00001

Rinsing Mixing port

With rinse liquid

With next sample

Mixing

In the mixing port

Maximum volume for preparation: 0,6ml

Number of reagent

for addition

Maximum 4

Number of liquids for mixing

Calibration method : Maximum 5 (one sample + 4 reagents)

Standard addition method : Maximum 6 (one sample + one

Standard + 4 reagents)

Auto dilute and

re-analyze

When the absorbance exceeds the range of the calibration curve:

The Optimum dilution ratio is automatically set.

(When it can not be calculated ,the dilution ratio is fixed at 10 times.)