Archive

Shandon Citadel 1000

ID-number: 015445
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Shandon Tissue embedding equipment Citadel 1000. 45-65°C. 220V. 500W. Volumen test container and waxbath each 1000ml.
siehe Storeview
More Information
Objektnummer B00015445
ID-number 015445
Object name Shandon Citadel 1000
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Manufacturer:                   Shandon

Model:                               Citadel 1000

 

 

 The following illustrations and descriptions are model-related and taken from brochures.

They do not reflect the scope of delivery of the system.

The exact scope of delivery can be found in the offer text.

 

  

 

TECHNICAL SPECIFICATIONS

Mains voltage range                                  220-240V ~

Netztrequenz                                             50-60Hz

                                                       Fluctuations in the mains voltage must not exceed ± 10% of the rated voltage.

power consumption                                   500VA

Wax bath-heater power                             (max) 80W

Wax bath temperature                                45-65 ° C

Volume of the reagent container                1000ml

Volume of the wax bath                              1000ml

Volume of fabric baskets - sorted               60

- unsorted                                                    about 40

mass                                                           52kg

Max. Dwell time per position                       99Std. 59min

minute Dwell time per position                    1 mm

agitation                                                      10 mins

Transport time between the steps               1 min

Max. Programmed delay time                      9 days

vacuum range                                              -0.2 to -0.4 bar

Fuse ratings:

Fuse in mains plug:                                     5A, 250V

(where applicable)

Mains current fuses for instrument:         

220-240V                                                      F1: F3,15A

                                                                      F2: T0,8A

transformer fuses                                          2x T3,15A

Fuses may only be replaced by technically competent persons.

Environment: General                                    Only for use in the room

                    temperature                                + 5 ° C to + 40 ° C

                    humidity                                      80% max. for temperatures <31 ° C

   50% max. for temperatures> 31 ° C but <40 ° C (without condensation)

                    height                                          Up to 2000 m

                    pollution degree                           2 (as defined in IEC1010-1)

                    installation category                     II (as defined in IEC1010-1)

 

Product group: Life science / Biotechnology