Archive

Sentron Argus X

ID-number: 011286
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Sentron ph-Meter Argus X.
siehe Storeview
More Information
Objektnummer B00011286
ID-number 011286
Object name Sentron Argus X
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Sentron

Modell:            Argus X

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

The SENTRON Red-Line probes series are for general purpose applications up to 60°C. Within the Red-Line series, there are five different probe-tip types:

-     Standard for general purpose use and for very small sample volumes,

-     ConeFET for application in highly viscous materials: jellies, pastes, slurries.

-     SurFET for application in direct surface measurements

-     LanceFET for application in semi-solids: fruit, meat, fish, soil etc.

-     LanceFET with handle for LanceFET applications where your hands might get slippery and you might loose your grip on the barrel when applying force to insert the probe in the sample or cold environments where gloves are worn.

To avoid disapointment, please make sure you have selected the right member of the comprehensive SENTRON probe family. This can be seen from the type-name on the barrel of the probe.

GENERAL

REFERENCE GEL may be observed as a viscous material on the tip of the probe. Some gel seepage from a new probe is normal and will not affect longevity or performance. Clean as above.

SAMPLES MUST BE aqueous liquids or semi-solids. Rinse with deionized or distilled water between samples.

TO ENSURE MIXING, stir samples or buffers for 5 seconds with the probe or a mag netic

stirrer, stop stirring and record results when stable.

PROTEINS, FATS AND OILS may be removed by scrubbing in a solution of Terg-A-Zyme (Alconox Company), Neutrad ® or Neutracon (Decon Laboratories), pepsin solution or similar product. Rinse thoroughly with deionized or distilled water.

SPARE PROBES should be rotated with those in active use every 30 - 60 days to minimize reference junction dehydration and reduce initial start-up time.

BUFFERS. pH 7.00 (phosphate) and pH 4.00 (biphthalate) buffers are less susceptible to CO 2 contamination than pH 10.00 buffer (borax or carbonate). When slope error occurs, it usually indicates a failing probe or contaminated buffer. If seen when using pH 10.00 buffer, try calibrating with pH 7.00 and pH 4.00 buffer. If a good slope is achieved, try a new bottle or different Iot of pH 10.00 buffer.

WHEN TESTING IN DIRECT SUNLIGHT or on a bright, reflective surface, use brown, opaque or shielded sample containers.


Specifications

Sensor:                                    Semi-conductor Ion Sensitive Field Effect Transistor (ISFET) sensor with patented ESD protection circuit.

Operating temperature:           0°C to 60°C

pH-range:                                pH 0 to pH 14

Reference compartment:        saturated KCI-gel, non-refillable

Dimensions: Probe lenght:      200 mm

                 Probe diameter:      10 mm

                     Cable lenght:      1.5 mtr

                         Connector:      There are different types of connector available. Please make sure that the probe you have received has a connector that matches with your meter. This can be done by checking the last two digits of your probe label: for the Argus and Titan series 08; for 1001 and 2001 series: 01; for 3001 series: 03; for 701 series: 11.

Wetted materials:                    Barrel and tip:              PVC

                                               Packaging material:     epoxy-resin

                                               Reference liquid:         gelled KCI

                                               Diaphragm:                  porous PTFE

Chemical resistance:              Refer to your SENTRON meter manual. If doubts concerning applicability arise, please contact your local dealer.

                                               If you have purchased a new probe to fit your old type pH-meter (701, 1001, 2001, 3001), contact your dealer to receive an updated information an the chemical-resistance of the probe.

Product group: pH-Measuring

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure