Rosemount CWA 5003
Objektnummer | B00017559 |
---|---|
ID-number | 017559 |
Object name | Rosemount CWA 5003 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Rosemount
model : CWA 5003
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
The CWA 5003 is a microprocessor-controlled analyzer for the determination of CO 2 and H 2 0 in powdered and granular solids.
Samples are loaded into a carrier "boat" and inserted into the inert-gas purged analysis furnace. The furnace temperature may be set by the user to any value up to 1000 °C.
Thermal decomposition of the sample in the furnace liberates carbon dioxide and water vapor.
Both gases, CO 2 and H 2 0, are then analyzed in a thermostatted BINOS® infrared gas analyzer.
The two resulting electronic output signals are processed by the analysis computer utilizing the associated set of analytical parameters, such as sample weight, ca[ ibration factors, blank value etc.
At the end of each analysis, the concentrations of CO 2 and H 2 0 in the sample, expressed in % by weight, are output both to the display and to the integral printer.
CWA 5003 Frontal View
1. Display screen
2. Operating keyboard (Softkeys)
3. Printer
4. Analysis furnace
5. Absorption traps
6. How-rate indicator
7. Mains-power switch
Instrument Layout
Fig. 1 shows a frontal view of the CWA 5003 analyzer.
All operating controls are ergonomically arranged on the Instrument front panel.
All fittings, inlets and outlets, are located on the instrument rear panel.
The two side panels and the rearpanel may be removed to provide access for servicing and maintenance operations.
The major components of the CWA 5003 are:
Gas circuitry and analysis furnace
BINOS® infrared gas analyzer
Analysis computer.
Characteristics Unit
Measuring range: H 2 O % 0 ,0001 ..........100
CO 2 % 0 ,0001 ..........100
Measurable amount of H 2 0 1) mg 0 - 300
Measurable amount of CO 2 1) mg 0 - 400
Resolution of display % 0 ,0001
Accuracy 1)2) % H 2 0: ± 0,001 bzw ./ or ± 1 % rel.
CO 2 : ± 0,001 bzw ./ or ± 0,5 % rel.
Analysis time, approx. 1) min 4 - 8
Sample weight, typ. 1) 200 mg - 1 g
Temperature, max. °C 1000
Carrier gas (standard) Nitrogen (N 2 )
Pressure roquired bar 2 - 4
Minimal purity % 99,995
Consumption, approx. I/min 1,0
Dimension (WxDxH), approx. mm 520 x 1050 x 850
Weight, approx. kg 100
Electrical connection
Voltage V 230
Frequency Hz 50 oder/ or 60
Power input kVA 1 ,6
Mains fuse (delayed-action) A 20
1) depending on sample, temperature and weight