Rittalwerk SK 3290 134
Objektnummer | B00012607 |
---|---|
ID-number | 012607 |
Object name | Rittalwerk SK 3290 134 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Rittalwerk
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Application
Enclosure cooling units are designed and built to dissipate heat from enclosures, by cooling the air inside the enclosure and protecting temperature sensitive components. Enclosure cooling units are particularly suitable for the temperature range of + 40 °C to + 55 °C.
Technical Data
Operating voltage: 230 V, 50/60 Hz
Rated current: 5,3 A
Starting current: 16,6A
Pre-fuse T: 6A
Duty cycle: 100%
Nom.refrigeration: 710W/800W
Usefull cooling output: 1400W/1400W
Refrigerant: R134a/950g
Permissible pressure: 25 bar
Temperature range: + 20 - +55°C
Noise level: 62dB (A)
Protection categ.:
Internal circuit IP54
External circuit IP44
Dimensions (WxHxD) mm: 600x400x426
Weight: 44 kg
Colour: RAL 7032
Technical Information
The cooling unit (compression refrigeration unit) consists of four main components: the coolant compressor, evaporator, condenser, and the control of expansion valve, which are connected by suitable pipework. This circuit is filled with a readily boiling substance, the collant. The R134a (Ch 2 FC 3 ) coolant is free from chlorine. It has an ozone destroying potential (ODP) of 0 and is therefore environmentally friendly. A filter dryer which is integrated in the hermetically sealed cooling circuit, provides effective protection against moisture, acid, dirty particles, and foreign bodies within the cooling circuit.
Programming
Pro- gram Level |
Changeable Parameter |
Min. Value |
Max. Value |
Factory Setting |
Description |
|
International enclosure temperature T |
30 |
45 |
35 |
The standard thermostat setting range is 35-45°C. The upper and lower limits can be adjusted through programm level 5 and 6. |
2 |
Set value of filter mat monitor |
4 |
40 (99 = off) |
99 |
Factory setting is the shut off valvue (99). To activate: 1. Install clean filter mat and let air conditioner cool for a few minutes. 2. Select programm level 2. 3. Push test button 10 seconds. Temperature difference is diplayed. 4. Using the ↑ button adjust the temperature 2-3 K above the displayed value. |
3 |
Imperial/metric units °C/°F |
0 |
1 |
0 |
The enclosure temperature can be displayed in both °C and °F. |
4 |
Security code |
|
|
123 |
In order to access program levels 5 - 9 the code "123" must first be entered through program level 4. |
5 |
Minimum thermostat setting |
20 |
35 |
30 |
The minimum thermostat setting can be adjusted from 35°C to 20°C. |
6 |
Maximum thermostat setting |
40 |
55 |
45 |
The maximum thermostat setting can be adjusted from 40°C to 55 °C. |
7 |
Alarm setting! for enclosure temperature |
3 |
15 |
5 |
Due to the standard factory setting of 5 K the fault code 1 is displayed when the enclosure temperature is 5 K or more above the thermostat setting. This alarm temperature setting can be adjusted from 3 to 15°C. |
8 |
Setting of PLC interface |
0 |
1 |
0 |
The factory setting is for serial interface. Parallel interface is activated by selecting 1. |
9 |
Turn off of evaporator fan |
0 |
1 |
0 |
With the facotry setting the evaporator fan turns off for 1 minute each time the unit cycles. This helps condensate drainage. This feature can bei turned off by changing the setting to 1. |