Qiagen EZ1 Advanced XL
Throughput of up to 14 samples per run.
Integrated device software. DSP virus card.
| Objektnummer | B00041529 |
|---|---|
| ID-number | 41529 |
| Object name | Qiagen EZ1 Advanced XL |
| Manufacture | Qiagen |
| Shipping | 4-6 weeks |
| Status | Provider |
Product group: DNA
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Manufacturer: Qiagen
Model: EZ1 Advanced XL
The following illustrations and descriptions are model-related and taken from brochures.
They do not reflect the scope of delivery of the system.
Please refer to the offer text for the exact scope of delivery.
Technical data
Operating conditions
Power 100-120 V AC, 50/60 Hz, 600 VA (North America and Japan) 200-240 V AC, 50/60 Hz, 600 VA (Europe) Mains voltage fluctuations must not exceed 10% of the rated voltage.
Fuses 6.3 A (250 V) slow-blow (for 100-120 V AC) 3.15 A (250 V) slow-blow (for 200-240 V AC)
Surge protection class II
Air temperature 15-30 ºC
Relative humidity 15-75% (non-condensing)
Height above sea level up to max. 2000 m
Operating location Indoors only
Pollution degree 2
Environmental hazard class 3K2 (IEC 60721-3-3) 3M2 (IEC 60721-3-3)
Transport conditions
Air temperature -25 ºC to 60 ºC in manufacturer's packaging
Relative humidity Minimum 15% to maximum 75% (non-condensing)
Environmental hazard class 2K2 (IEC 60721-3-2) 2M2 (IEC 60721-3-2)
Storage conditions
Air temperature 5 °C to 40 °C in manufacturer's packaging
Relative humidity Minimum 15% to maximum 75% (non-condensing)
Environmental hazard class 1K2 (IEC 60721-3-1) 1M2 (IEC 60721-3-1)
Mechanical data and features
Dimensions Width: 51 cm Height: 57 cm Depth: 51 cm 57 cm (including power plug)
Weight 48kg
Device features ï¬
Automatic nucleic acid isolation using magnetic particles ï¬
Desktop device ï¬
Protocols on EZ1 Advanced XL Cards ï¬
Use only with QIAGEN EZ1 kits ï¬
Aspirate and dispense 14 samples or reagents simultaneously using the 14-channel pipetting head ï¬
Separation of the magnetic particles from the reaction mixture using a patented technology ï¬
Parallel processing of up to 14 samples per run ï¬
Control via user interface (VFD display) ï¬
Sample temperature control through integrated heating system
Data traceability
The control panel barcode reader and keyboard enable tracking of sample and consumable data. System and run data are saved in a report file that can be printed directly or transferred to a PC. Report files can be processed with a LIMS (Laboratory Information Management System) or other programs.
pipetting head
Includes 14 precision syringe pumps, each with a tip adapter that automatically attaches filter pipette tips. 50–1000 µl of liquid can be aspirated and dispensed into each pipette tip. The pipetting accuracy is: 50-100 μl: ± 5% 100-1000 μl: ± 2% The syringe pumps are air-filled. Saline liquids, alcohol, solvents and/or magnetic particle suspensions can be aspirated and dispensed. Air bubbles (air gaps) can be sucked in to prevent sucked liquid from dripping out. The pipetting head contains a magnet that enables the magnetic particles to be separated from a suctioned liquid. The filter pipette tips are picked up from the tip rack and placed back there after use. The pipetting head moves in the Z direction above the work platform.
Heating system
Accommodates the temperature-controlled positions of the reagent cartridges and has a working temperature range from ambient temperature to max. 95 ºC. The temperature accuracy of the heating block at 60°C is: ± 2°C.
Filter pipette tips
Are automatically attached to the tip adapters of the pipetting head during a protocol run to enable aspiration and dispensing of liquids. Pipetting volume 50–1000 μl per tip. Up to 28 pipette tip holders (each with one pipette tip) can be placed in the tip rack on the work platform of the EZ1 Advanced XL per run.
Consumables
The reagents are loaded onto the work platform in the form of reagent cartridges. These cartridges are supplied by QIAGEN pre-filled with the reagents. Up to 14 reagent cartridges are placed in a cartridge holder on the work platform per protocol run. Samples are placed in 2 mL sample vials on the work platform. Work steps that involve heating take place in the heating system, in which the temperature-controlled positions of the reagent cartridges are located during a protocol run. The purified nucleic acids are collected in 1.5 ml elution tubes.
UV lamp
Produce ultraviolet light with a wavelength of 253.7 nm (equivalent to Type C UV light).
capacity
Up to 14 samples per run