Archive

Planer Kryo 10 II

ID-number: 012637
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Planer Freezer Kryo 10 Series II. With integrated Printer. Temp +30°/-180°C. H/W/D: 30/22/22 cm.
siehe Storeview
More Information
Objektnummer B00012637
ID-number 012637
Object name Planer Kryo 10 II
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Planer

Modell:            Kryo 10 II

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

The following descripton is correspondig to Modell Kryo 10 Series II

The Kryo 560 - 16 incorporates all of the critical features expected from a high dass biological freezer. The system is specifically designed with full system safety protection. The -180 °C end temperature ensures sample integrity during transfer to storage whilst the flexibility of the system, including protocol stage transition based an sample or chamber temperature or time, is ideal for the more demanding protocols associated with the most advanced cryopreservation techniques.

The high capacity LNP4 active nitrogen pump offers both faster cooling rates and, when combined with a LAB 30 dewar, a largo reservoir offering the reassurance of an extended hold time at the protocol end temperature. The system sample capacity is sufficient for the busiest laboratory and the state of the art compact design will enhance the most modern facility. The top opening chamber, combined with a unique forced laminar ilow pattern of the coolant and cryogenic insulation, ensures even and accurate temperature control in all phases of the protocol and prevents the lid from freezing shut at cryogenic temperatures.

The MRV controller system has been created to offer multiple protocols whilst remaining simple to programme and operate. Both during and after a run it offers the widest range of displayed information, alphanumericaily and graphically via the easy view display and as a print out an the integral full view printer. Validation is a high priority and the MRV offers password controlled access an multiple user levels, time and date stamping, programme preview/verification before running and data storage for the last 10 runs for subsequent printing.

User calibration with associated hard copy is featured and PC connection compatible with our comprehensive Delta T TM software application is standard. These help protect against power failure and PC failure when running wich software. Processor or system problems are controlled and the system restarts to protect samples. For example all control and data systems are separated, the controller can be removed from the operating freezer wich no loss of programme integrity; data storage and processing are run an completely isolated electronic systems.

The Planer Kryo 560 - 16 fully featured Tissue Bank freezer for cryopreservation of Bone Marrow, Stern Cells, Skin, Cord Blood and other critical high volume samples

q    Designed for freezing of samples in bags, ampoules and straws

q    Controller displays demand, sample and chamber temperatures, programme stage and current temperature graphic

q    Menu driven controller, simple to programme and operate

q    Protocol stage trigger an sample or chamber temperature or time

q    Unique forced laminar flow system ensures efficient, even cooling

q    Standard operating features:­

• Start above ambient

• Controlled heating

• Dato Printing (integral printer)

• Comms port for PC connection

• Fast cooling rates

• Multiple safety features

SPECIFICATION OVERVIEW

·            Chamber volune: 16 Iitres

·            Capacity: 11 x 250/500 rni bags, horizontally or vertically in chamber

·            Ampoule capacity: 726 x 2 ml in basktets

·            Straw capacity: 608 2 ml on canes (horizontal)

·            Lower temperature limit: -180 °C

·            Cooling rates: -0.01 to -50 °C/min

·            Controlled heating rates: 0.01 to 10 °C/min

·            System controller: MRV

SYSTEM REQUIREMENTS

5 psi or 22 psi Liquid Nitrogen Supply

TECHNICAL SPECIFICATION - Kryo 560 - 16

System Specification

Range

+30 °C to -180 °C

Heating rate

0.01 °C/min to 10 °C/min

Cooling rate

-0.01 °C/min to -50 °C/min

Controller accuracy

±(O 3 + 0 005 x TM) °C (where TM is the magnitute of the temperature)

Storage temperature

-10 °C to +50 °C

Storage humidty

5 % to 95 % relative humidity non-condensing

Operating temperature

5 °C to 40 °C

Operating humidity

5 % to 90 % relative humidity non-condensing

Controller Specification

Dimenstons

80 mm high x 220 mm wide x 350 mm deep

Weight (approx.)

2.6 kg

Display

240 x 64 LCD with CCFL backlight

Printer

320/640 dot thermal printer

Keypad

20 key membrane keypad

Programmable Cooling Rate Range

-0.01 °C/min to -99.9 °C/min

Number of profiles

10

Steps per profile

32

Number of stored runs

10

Chamber Specification

Weight (kg)

23

Capacity (litres)

16

Chamber dimenisions

350 mm high x 230 mm wide x 230 mm deep

0.25 ml straws

608 horizontal or 250 vertical

0 5 ml straws

68

2 ml ampoules

726

50 cc blood bags

22

250 cc blood bags

11

500 cc blood bags

11

Power requirements (inc. MRV Controller)

115\1~ 50/60Hz 1500VA / 230V- 50/60Hz 1500VA

Recommendation of additional equipment

5 psi System          System Pump - LNP4-C

                              System Dewar - MVLAB 30

22 ps System         System Cylinder MVEURQCYL23OSB

                              Phase Separator MVPHASE

(Alternative)

22 psi System        Vacuum Jacketed Pipe Work System

                              Phase Separator - MVPHASE

Product group: Freezers

We can't find products matching the selection.