Pharmacia UniCap 100
Objektnummer | B00013509 |
---|---|
ID-number | 013509 |
Object name | Pharmacia UniCap 100 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Calibrator
Calibrators are samples with known concentration levels used to obtain a calibration curve. The curve is used to calculate the results for the unknown samples.
Calibration Code
The code used to connect the conjugate and in some cases the ImmunoCAP with the stored calibration curve.
Curve Control
Curve Controls are used to verify that the stored calibration curve is valid for the reagents used in the actual assay run.
FluoroC
FluoroC is a solution used when calibrating the fluorometer. The fluorometer is calibrated with a fixed time interval.
Monthly Calibration
Monthly Calibration describes the use of stored calibration curves. A calibration curve has to be run when new lot numbers of components are introduced or if the Curve Controls are out of range. In the daily assay run only curve controls need to be included. For a more detailed explanation please read chapter 4, Monthly Calibration in the Users File.
QC
You can define Quality Controls to be automatically added in each assay run. The results can be logged and presented in Shewhart plots.
CAL Calibration Curve
CC-1 Curve Control Low
CC-2 Curve Control High
QC Quality Control
slgE UniCAP Specific IgE
tlgE UniCAP Total IgE
Phad UniCAP Phadiatop
ECP UniCAP ECP
Sample Carousel
1-48 Positions for tubes A-D Positions for conjugate
E Position for substrate
F Position for FluoroC
H Position for stop solution
ImmunoCAP Dispensor
Load the ImmunoCAP carriers in the ImmunoCAP dispensor; remove the tip and place the carrier straight down in the dispensor.
Keyboard and Display
? If there is a question mark you can use the yes or no key.
If there is an underline you can type a new value. The enter key will save the data you haue typed.
If there is a message you can press the enter key to return to previous display.
If you want to quit the mode you are in press the mode key. Note that mode will not save previously entered data.