Pharmacia HPLC
Objektnummer | B00013059 |
---|---|
ID-number | 013059 |
Object name | Pharmacia HPLC |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Kommentar: Dokumente engl. (nur für IDNR.: 09253)
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Uvicord SII
Introduction
Pharmacia LKB Uvicord SII Code No. 18-1004-50 is a compact single beam UV-monitor with flow-through cell for monitoring the eluant from various column separations. Available wavelengths, selected by a combination of lamp and interference filter are 206, 226, 254, 280, 313, 365 and 405 nm.
Pharmacia LKB Uvicord SII is housed up in one combined optical and electronic unit. This detector simultaneously produces two absorbance outputs - one fixed at 2 AUFS and one selectable from 0.005 - 2 AUFS in 9 steps. Thus, with the selection of the appropriate absorbance range, Uvicord SII enables monitoring of both high and low concentration substances simultaneously with a dual-channel recorder.
Substances such as non-aromatic peptides, amino acids, lipids, nucleotides and certain carbohydrates have strong absorption at 206 nm whereas at higher wavelengths they show little or no absorption. Furthermore, most proteins also exhibit greater absorption at 206 nm than they do at 280 nm. By employing all fully integrated electronics and the very latest detection principles Uvicord SII performs to specification at ambient temperature and under cold room conditions.
Technical Specifications
Operating wavelengths 206, 226, 254, 280, 313, 365 and 405 nm.
Absorbance ranges 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1 and 2 AUFS.
Noise <1x10 -4 AU measured peak to peak in a dry cell.
Drift <5x10 -4 AU/h at constant temperature.
Operating temperature 0 to +30°C.
Recorder outputs 100 mV for selected absorbance range and 100 mV for fixed 2A range.
Integrator output 1 V = 2 AU.
Power consumption 20 W.
Mains Voltage 100/115/120/220/240V ±10%, 50/60 Hz.
Dimensions (LxWxH) 313 x 131 x 147 mm.
Weight 4.3 kg.
GradiFrac
Introduction
GradiFrac (Code No. 18-1993-01) from Pharmacia Biotech AB combines the functions of gradient programmer and programmable fraction collector for standard chromatography
applications. It forms the basic unit of GradiFrac System, which includes GradiFrac, Pump P-1, Monitor UV 1, Recorder REC 102, Valve IV-7, Switch Valve PSV50 and a mounting rack. Gradients are generated using a single pump and a Switch valve. Easy-to-use programming allows automatic gradient formation for preprogrammed separation methods. Up to ten methods can be stored in the instrument memory. Stored methods are retained in memory even when the power is switched off. GradiFrac can also be used in manual control mode, and manual adjustments can be made while a method is running.
GradiFrac can be programmed to collect fractions based on time, volume or drop count. Fractions can also be collected in a peak detection mode when a suitable monitor is connected. Tube racks accommodate tubes with diameter 10-18 mm and length 50-180 mm.
Technical specifications
Programming base ml or min
Programming capacity 10 separate methods, 52 breakpoints each
Memory protection EEPROM
Pump control Remote for Pump P-1 and HiLoad Pump P-50
Gradient formation Single pump and switch valve
Fraction collection
Time base 0.1-99.9 min
Volume base 0.1-99.9ml
Drop base 1-999 drops
Tube change time 0.3-0.6 s (tube rack 18 mm)
Rack capacity 95 tubes, rack 18 mm
Event mark 50 ms contact closure
Flow diverter Solenoid valve PSV-50
Monitor input range 0-10 mV, 0-100 mV, 0-1000 mV
Recorder control Controls REC 101 and REC 102
Valve control 3 outports for Solenoid Valve PSV-50 (switch valve, flow diverter, auxiliary)
Mixer 0.6 ml
Power supply 24 V Power Supply for 100-240 VAC, 50-60 Hz
Power consumption 15 W maximum
Dimensions (w x d x h) 290 x 300 x 390 mm
Weight 3.9 kg
Working temperature range: 4-40°C
Safety standard Conforms to IEC 1010-1 and UL 1262 requirements.
GradiFrac System
Recorder REC 102
Introduction
Pharmacia Biotech model REC 101 (Code No. 18-1001-42), single-channel recorder and model REC 102 (Code No. 18-1001-43), dual-channel recorder are compact recorders designed to meet the challenging demands of todays technology.
These instruments are part of the new generation of high quality, flat-bed recorders from Pharmacia Biotech which use a null balancing potentiometric system. They can accommodate a range of input voltages, offer a selection of chart speeds, and allow many functions to be remotely controlled.
The recorders have sophisticated features such as electric pen lift, grid and home functions, forward and reversed paper feed. Paper is transported at a constant velocity selected from the 14 different chart speeds in the range from 0.1 mm/min to 20 mm/s, and can be synchronized with the pump to enable chromatogram comparision.
The positions of the two independent pens (REC 102) represent the levels of the two corresponding inputs from which the time functions are drawn. Owing to the nature of the dual-channel recorder, the pen of channel 1 is always 2.5 mm behind the pen of channel 2. Full sensitivity ranges from 1mV to 20VDC.
Recorder (REC 102) is equipped with one chart drive control panel and two independent, isolated servo systems with a control panel for each channel. Recorders REC 101 and REC 102 have an attractive design with much attention having been paid to ergonomics: control functions are well positioned, keys and switches are very accessible, and paper is easily changed. Pens, paper and keyboard are all protected from accidental spillage by the moulded cover which fits over the recorder. The pens, which are nonsmear and disposable, give clear, accurate traces for instance evaluation. Chart paper is of a high quality, and 200 mm wide.
Improved control capabilities permit the use of these recorders in all Pharmacia Biotech chromatography systems.
Technical Specifications
Recording channels: REC 101: 1-channel
REC 102: 2-channels
Input ranges: 1, 2, 5, 10, 20, 50, 100, 200, 500 mV and 1, 2, 5, 10, 20 V
FSD (lull scale deflection) for each channel
Variable ranges: 40-100 % FSD
Accuracy of span: < 0.3 % FSD
Non-linearity: < 0.3 % FSD
Dead zone: < 0.2 % FSD
Pen response time: 0.2s
Input impedance: 1 MΩ DC
Input: Floating asymetrical
Input terminals: Low profile" banana plugs
Input current: < 5 nA
Maximum input voltage: Max. 60 V between channels and max. 30 V between channel and ground
Common mode rejection: > 130 dB
Zero adjustment range: -50 % to +150 % of FSD
Zero position: Choice of left or right-hand side of chart by a switch on rear panel. (Right-hand zero point on delivery)
Zero drift: < 1 µV/ °C
Pen lift: Electrical, independent control of pen 1 and pen 2, automatic pen lift at power down or after 30 s stop of chart speed
Chart speed range: 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 mm/s or mm/min
Chart paper: 25 m roll according to DIN 16 230
Chart paper life: Max. 4 167 hours at lowest chart speed. Min. 20 min at highest chart speed
Pens: Disposable, fibre-tip cartridge
Peristaltic Pump P-1
Introduction
The Peristaltic Pump P-1, 120 V (Code No. 19-4611-02) and 220 V (Code No. 19-4610-02), is a single channel laboratory pump for use in liquid chromatography and other applications where accurately controlled liquid flows are required. Pumping action is provided by a roller cage driven by a stepper motor controlled by a range selector and a continuously variable potentiometer. The motor speed is almost independent of temperature (0-40°C) and load thus giving an accurate and reproducible flow rate under all conditions. An asymmetric shape gives the pump a very low pulsation in the forward direction. The backward direction has a pulsation which is more equal to traditional peristaltic pumps. Maximum flow function and a connector for remote control and pulse counting are provided.
Technical Specifications
Flow rate range 0.6-500 ml/h depending on tubing diameter and range selector (x1 or x10).
Standard tubing Silicone rubber of internal diameters;1.0 mm, 2.1 mm and 3.1 mm
Voltage 100 or 120 V ± 10 %
220or240V±10%
Frequency 50-60 Hz
Max Power 20 W
Temperature range 0-40°C
Dimensions 112 x115x145 mm (WxDxH)
Weight 1.7 kg
Motor Stepper motor
Remote control The following operations can be obtained via the remote control socket
Outputs: Actual speed (0-200 Hz)
Forward/backward direction ON/OFF
Inputs: Forward /backward direction.
Speed control (0-200 Hz)