Pharmacia 2D-DIGE
| Objektnummer | B00010246 |
|---|---|
| ID-number | 010246 |
| Object name | Pharmacia 2D-DIGE |
| Status | Stock unit |
Product group: Life science / Biotechnology
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Pharmacia
Introduction to the 2D 2920 Master Imager
The 2D 2920 Master Imager is a multi-wavelength fluorimager capable of fluorescence measurements on 2D protein gels. It has a maximum scanning area of 240 X 280mm at resolutions of up to 50 microns. Fluorescence measurements may be made using any combination of up to six excitation and emission wavelengths, within the range 400 to 700 nm. The 2D 2920 Master Imager is supplied with a high specification PC, and is extremely easy to use via its Windows 95 TM compatible software and multi-format image export capabilities.
The protein gel is placed horizontally on the carrier plate, which is automatically loaded into the instrument when a scan is requested. A cooled CCD camera scans the required area capturing a number of FRAMES, which are combined to produce an IMAGE of the fall gel. Each frame is of fixed size (approximately 50 X 70 mm).
A high resolution mosaic image (an image made up of frames) can be produced by either edge or top illumination of the protein gel using a high power xenon light source with interference filters for fluorescence measurements. The edge illumination light guide is fixed in position at the rear edge of the sample. The top illumination light guide moves with the camera. The edge illumination method is especially applicable to gels where it distributes the available light between the glass plates. The software enables the illumination method and wavelengths to be set to capture multiple images of the CyDye TM labelled protein samples present on the same gel.
Gel images may then be subjected to detailed analysis within the 2D Master software package or exported in a variety of standard fite formats for more specific analysis using the Image Master TM Software.
Specifications
Active scanning area: 240 X 280 mm
Spatial resolution: Under software control to 50 microns
CCD Camera:
Detector: Kodak KAF 1600 CCD
1,478,980 pixels
9 micron square pixels
85,000 electrons full well capacity
Readout noise < 8 electrons/pixel
Spectral response 400-900 nm
Quantum efficiency : Cy2 >30%
Cy3 >35%
Cy5 >37%
Noise reduction: Active peltier cooling to -40°C (nominal)
Electronics: Full digital drivers
16 bits per pixel (65,535 grey levels)
Sensor positional accuracy: 2.5 microns
Sensor positional repeatability: 25 microns
Illumination sources: 150W Xenon Lamp
(Nominal life 2000 hours)
Excitation:
Wavelength range: 400-700 nm
Epi-luminescense: Dua l fibre optic probe
Translucive: Lightline fibre optic probe
Wavelength selection:
Excitation:
Epi and Translucive: 6 position 25mm interference filter wheel
Emission: 6 position 50mm interference filter wheel
Control: Excitation and emission filter wheels controlled by software.
Computer: Minimum specification 400MHz Pentium II processor
256 MB RAM, 6.4 GB HDD
Dimensions (W x D x H): 1002 x 652 x 632 mm
Weight: ~100 kg (excluding computer)
Power requirements: 220/110 VAC 50/60Hz; 500VA