Sold

Pharmacia 2152

ID-number: 009345
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Pharmacia LKB LC-Controller 2152.
Quotation
siehe Storeview
More Information
Objektnummer B00009345
ID-number 009345
Object name Pharmacia 2152
Status Stock unit

Product group: HPLC-Miscellaneous

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Pharmacia

Modell:                       2152

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

2152 HPLC Controller is a state-of-the-art central processing unit designed for precise and accurate gradient elution and complete HPLC system control. This Compact and modular unit portions solvents from two LKB 2150 HPLC Pumps to produce accurate and reproducible gradients over an extended range of solvent composition. Alternatively, it can be used to control a switching valve for low pressure gradient mixing with a single 2150 HPLC pump.

The microprocessor-based 2150 Controller enables precise volume fraction collection as well as volumetric calibration of the recorder chart speed (when used with an LKB fraction collector and recorder) — an invaluable feature for flow programming. It is also the only Controller which offers exact synchronization of your gradient profile and chromatogram by compensating for the lag in system response.

For accurate and efficient methods development, the 2152 incorporates a variety of sophisticated features such as editing, File storage, scaling functions, flow programming and link-file capabilities. For complete HPLC system control, it can also be used to control a wide variety of auxiliary instrumentation, eg. autosampler, fraction collector, column ovens or valves.

Accurate and reproducible gradients

The 2152 HPLC Controller operates together with the 2150 HPLC Pump to provide smooth, accurate and reproducible gradient elution. Even at the extremes of gradient composition, where very low flow rates are required, the 2150 pump (minimum flow: 10 µl/min) ensures precision. This feature makes an LKB HPLC System ideal for running gradients an microbore columns.

The small displacement volume of the 2150 pump-head together with a low internal volume ensures that solvent changeover is both smooth and rapid.

Precision – even at extremes of gradient composition.

Gradient profiles are generated by a simple "corner point" system. Each "corner point" defines the time, flow and composition (%B) of the gradient. Up to 200 points can be defined allowing virtually any shape of gradient to be formed — from simple "two point" linear gradients to curved and complex gradients.

Ideal for methods development

For efficient modification of a previously programmed gradient profile, the 2152 Controller is equipped with dual scaling functions. These functions offer simple and rapid modification of an existing program by changing the scale of time and/or solvent composition. An edit facility permits modification of all gradient parameters — even during a run.

Up to 10 different programs can be stored in the memory and a link-file function permits automatic repetition of a particular gradient or successive recall of different gradients in a specified order. Combined with an autoloader, this feature enables fully automated methods development.

Any gradient can be reviewed on the recorder by simply pressing the LIST button. During a run, gradient profiles are automatically superimposed on the chromatogram with exact synchronization of solvent composition and peak retention volumes.

Easy to program

Programming the 2152 Controller is simplified by a user-friendly question and answer routine. You can choose between a BASIC MODE of operation requiring a minimum of programming or an ADVANCED MODE with full control over all operational parameters. In the BASIC MODE, key parameters such as pressure limits are preprogrammed to reduce programming steps. In both modes, programming errors are indicated by messages on the alphanumeric display.

A comprehensive 3-level display simplifies operation by continually displaying the elapsed time, flow rate, solvent composition, pump and program status, and the activation of auxiliary functions. Pressure limits, initial and final gradient composition, gradient parameters and storage file status are displayed on user command.

Complete HPLC system control

The 2152 HPLC Controller can be used to activate, at preprogrammed times, up to five pieces of auxiliary HPLC equipment. For fully automated chromato­graphy, the 2152 Controller can be interfaced with an autosampler. Control of external valves can be used, for example, to automatically regenerate your column.

Event marking can be used to record programmed changes in flow and the activation of auxiliary functions. Commands to the LKB 2211 SuperRac fraction collector give complete automation of preparative chromatography.


Technical specifications

Continuous displays                         Elapsed time, flow rate; composition, pump status,

                                                         program status, gradient or isocratic operation, auxiliary      function status.

Optional displays                             Minimum pressure limit, maximum pressure limit, actual (displayed on user command)                                        pressure, initial concentration (%B), final concnetration        (%B), programmed gradient conditions, storage file       status.

Gradient programming                     Max. 20 corner points each of which can be programmed    for:

                                                              Time 0.1-999.9min

                                                              Flow rate 0.01 –5ml/min

                                                  %B 0-100% in 1% increments (min rate of linear change: 5µl/min).

                                                         Auxiliary functions ON/OFF.

Total run time                                    0.1-999.9min.

Scaling functions                              For modification of time and/or solvent composition axes.

Storage files                                     10 files available to obtain up to 200 corner pints, to repeat gradient or to run different gradients in a specified      order.

List function                                      For recorder display of gradient (1V = 100% B).

                                                         List time : 30s/file

                                                         Gradient can also be plotted during operation.

Delay function                                   Permits chromatograms and gradient profile to be exactly   correlated

Event marks                                     Indicate activation of auxiliary functions and programmed     change in flow.

Valve function                                   Controls 2-solvent portioning valve for feeding single            HPLC pump.

Auxiliary valve function                      For ON/OFF delivery of a 3 rd solvent.

Auxiliary event functions                   3 available, (ON/OFF, 0-999.9min). Can be used to give      inject signal to an autosampler and restart gradient.

External control                                 LKB 2150 pumps and 2211 fraction collector.

System warnings                             Triggering of pressure limits. Error messages for incorrect entries.

Method storage                                10 gradients (all operating parameters). Can be edited at     any time.

Operating temperature                    0-40°

Mains requirements                          110, 115, 120, 220 or 240V, 50/60 Hz

Power consumption                         70W

Dimensions (WxDxH)                     365 x 265 x 145mm

Weight                                             6.2kg

Part of labexchange logo
Search engine powered by ElasticSuite