HPLC-Systems

PerkinElmer Flexar FX UHPLC Autosampler

Preis auf Anfrage
ID-number: 13544
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
The Flexar FX-UHPLC Autosampler is a powerful, high-throughput UHPLC autosampler that can operate at up to 18,000 psi. As standard, it is equipped with Peltier cooling and a high-pressure injection valve for the most demanding UHPLC applications. Hardware specifications:. Pressure limits: 18,000 psi (1,240 bar). Injection modes: Fixed loop: 5x sample overfill. Partial Fill: Variable injection volumes. µL pickup: injections without additional sample loss. Injection volume: Fixed loop mode: 2 µL to 500 µL, depending on loop volume. Partial fill mode: 0.1 µL to 2.45 mL (up to half the loop volume). µL pickup mode (no sample loss): 1 µL to 977 µL, depending on loop volume. Injection cycle time: As fast as 12 seconds in Partial Fill mode or 35 seconds in µL Pickup mode. Loop volumes: 2 µL to 5 mL, 10 µL standard. Sample/rinse syringes: 100, 250, 500, 1000 and 2500 µL; 250 µL standard. Injection repeatability: Fixed loop mode: 0.3% RSD. Partial fill mode: 0.5% RSD for injections ?5 µL, 1.0% RSD for 1-4 µL injections. µL pickup mode: 0.5% RSD for ?5 µL injections, 1.5% RSD for 1 µL injection. Sample transfer: <0.005% (caffeine), with programmable needle cleaning. Sample capacity: 2 x 96-well microplates (high and low); 100 2 mL vials; 200 0.2 mL vials; 25 6 mL vials. Supported tablet types/microplates: . - 100-vial tray for 2 mL vials (standard). - 85 vial tray for 80 2 mL vials plus 5 6 mL vials. - 80 vial dilution tray for 80 2 mL vials plus 60 mL dilution tank. - 205 vial tray for 200 0.2 mL micro vials plus 5 2 mL vials. - 25-vial tray for 25 6 mL vials. - 2 x 96-well microplate, high. - 2 x 96 well microplate, low. All of these trays and plates are supported by Peltier cooling and heating options. Derivatization/Serial Dilution: Both are supported by liquid mixing without the need for additional hardware other than an optional sample tray. Supported in Chromera® version 4. 1 or later, TotalChrom® and Agilent® EZChrom® 3. 3. 2. Other specifications include needle height above vial or plate bottom, number of injections per vial/plate, materials used with the sample Coming into contact, programmable needle cleanings, Peltier options, temperature ranges for Peltier cooling and heating, synchronization of injection with pump piston position for optimal reproducibility of retention times, support for a second solvent flush in Chromera version 4. 1 or higher, operating specifications such as output, input , noise level, operating and storage temperature, humidity, safety and EMC compatibility, performance requirements, viscosity range, dimensions and weight of the autosampler with and without Peltier options, maximum allowable weight that can be stacked on the autosampler and software, system control and communication specifications Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00013544
ID-number 13544
Object name PerkinElmer Flexar FX UHPLC Autosampler
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Perkin Elmer
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: HPLC Systems