Mass spectrometers

PerkinElmer Clarus SQ 8T with Clarus 580 GC/MS Sys

Preis auf Anfrage
ID-number: 13532
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
We can add a compatible headspace autosampler upon request. Description. With PerkinElmer's Clarus SQ 8 GC/MS, laboratories of all types and sizes finally have a state-of-the-art tool that offers both unmatched sensitivity and unparalleled stability. Why settle for limited performance when there's now a solution that gives you consistently ultra-low detection limits every time. Imagine the increased confidence in your results. Imagine the increased productivity in your lab. Designed around an advanced, fast quadrupole mass spectrometer, the Clarus SQ 8 GC/MS acquires a large number of spectra (12,500 amu/sec) across each GC peak. This enables the clear definition and quantification of extremely narrow chromatographic peaks to provide exceptionally accurate and precise data. The instrument also gives you the widest mass range available in gas chromatography (1-1200u) and detection limits never before seen with a single quadrupole GC/MS. System configurations. Clarus SQ 8S. Clarus SQ 8T. Clarus SQ 8C. Ionization type(s). EGG. EGG. EI/CI. S/N ratio specification. 650:1. 800:1. 800:1. Turbomolecule pump capacity. 75 L/sec. 255 L/sec. 255 L/sec. Pump expiration time. < 5 min < 3 min < 3 min The PerkinElmer Clarus SQ 8 Mass Spectrometer (MS) is a detector designed to be coupled to the Clarus 580 and 680 Gas Chromatograph (GC). The gas chromatograph-mass spectrometer (GC/MS) is controlled and data is analyzed by the PerkinElmer TurboMass™ GC/MS software system. Clarus SQ 8 T - Compatible with the Clarus 680 GC, with electron impact ionization (EI) and 255 L/s. turbomolecular pump. Sensitivity. Test. Crowd. Signal-to-noise ratio performance. EI full scan. 1 pg octafluoronaphthalene. 800:1. Hardware. Ion source. PerkinElmer SMARTsource™ - Simplified maintenance and removal technology (EI and CI compatible). Thread. Marathon™ - designed to last. Mass range. 1.0 – 1,200 u (amu). Detector. Clarifi Detector - Long-lasting, high-sensitivity electron multiplication detector. Analyzer. Quadrupole with pre-filter. Mass stability. ± 0.1 m/z over 48 hours. EI voltage. 10 – 100 eV. Vacuum pumps. 255 L/sec. (Nitrogen) air-cooled turbomolecular pump (230 L/s helium pumping capacity). vacuum gauge. Simple wide range meter (standard on all models). Pump expiration time. 255 L/sec. Turbomolecular pump: <3 minutes for air/water testing, <90 minutes for quantitative stability. Temperature settings. SMARTsource: Adjustable 50 ?C - 350 ?C, GC transmission line: Adjustable 50 ?C - 350 ?C. Carrier gas flow rate. 255 L/sec. turbomolecular pump systems: 5 ml/min, 75 L/sec. turbomolecular pump systems: 1.5 ml/min. mass calibrant. PFTBA (FC-43) gas, triazine (for high mass applications), user selectable. MS isolation. Swafer micro-channel flow technology. Field upgrades. Positive/negative chemical ionization (255 L/sec), standard to large turbomolecular pump (75 L/sec to 255 L/sec), water cooling (all models). Perfomance. MS data acquisition. Full Scan, Selective Ion Monitoring (SIM), Simultaneous Full Scan Selective Ion Monitoring (SIFI). Scan rate. Fully variable up to 12,500 amu/sec. Acquisition rate. 100 points/sec. (SIM). Features/Run. 32 functions or 32 ions per function. Linear dynamic range. 106 depending on the capture rate. Data system. Software. TurboMass™ 6. 0, developed for the Windows 7 Professional operating system. Methods. Electronically transferable between all TurboMass and Clarus GC/MS systems. GC capture. Complete control and data processing of a single GC/MS with up to 2 GC detectors. MS vote. UltraTune™: Standard tune environmental tuning optimized for EPA methods; Custom Tune custom optimization. Reporting. Included in all models, with specialized reports for: Environmental and forensic applications. Optional software. MS Libraries: NIST mass spectral library, including AMDIS deconvolution, Wiley mass spectral library Maurer/Pfleger/Weber library of drugs, pollutants, pesticides and metabolites. Advanced processing: Ion Signature deconvolution software. Physically. Electricity. 120 VAC ± 10% at 50/60 Hz ± 1% 1,000 VA, 230 VAC ± 10% at 50/60 Hz ± 1% 1,000 VA. Temperature. 10?C – 30?C (10?C – 35?C with water cooling option). Relative humidity. 20 – 80% non-condensing. Weight. 49.9kg (110lbs). Dimensions (HxWxD). Individual MS: 50 x 32 x 77 cm (20 x 13 x 30 inches), Clarus SQ 8 T GC/MS (with autosampler): 83 x 98 x 82 cm (33 x 39 x 32 inches) Labprocure is responsible for this Device.
Quotation
More Information
Objektnummer C00013532
ID-number 13532
Object name PerkinElmer Clarus SQ 8T with Clarus 580 GC/MS Sys
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Perkin Elmer
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: Mass spectrometers

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure