Product group: Photometers / Spectrophotometers
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
VERSATILITY WITH PERFORMANCE
Luminescence spectroscopy includes the measurement of fluorescence, phosphorescence and bio- and chemiluminescence. The technique is used in a wide variety of applications where high sensitivity and selectivity are important, particularly in biochemical and environmental analysis and pharmaceutical and industrial research.
Perkin-Elmer's Model LS-50B offers outstanding sensitivity and selectivity for all these analyses. The dual scanning monochromators are controlled by sophisticated PC software and a pulsed xenon lamp is used as an excitation source. A cut-off filter is automatically inserted in the excitation beam for eliminating stray radiation when exciting at long wavelengths and the emission monochromator has a filter wheel with five cut-off filters. The Instrument is fitted as standard with a sample photomultiplier covering the wavelength range 250-650 nm.
A comprehensive range of computer controlled accessories is avaliable for the Model LS-50B, permitting the measurement of widely differing samples including Iiquids, solids such as powders and films and suspensions of Iiving cells. The instrument has as standard a single position, water thermostattable cuvette holder.
VIEWING DATA
The experimental data are plotted on the screen in real time and are stored in a destination file for recall. A VIEW menu provides the facility for rescaling, split screens, multiple overlays and a cursor for determining ordinate and abscissa values.
The stored data can be exported to other PC based software such an Enzfitter*. LabCalc or Lotus 1-2-3 etc.
DATA MANIPULATION
Several mathematical operations are available from the data menu, including; area calculations, arithmetic functions such as add, subtract, multiply, divide, derivatives, logs, antilogs and data normalization, automatic peak determination and variable point Savitzky Golay smoothing.
An exclusive macrolanguage OBEY routine allows you to create methods specific to your analysis which can be stored on disk for future use.
CORRECTED SPECTRA
The Model LS-50B produces excitation spectra which are automatically corrected for the wavelength artefacts of the excitation system. Emission spectra are corrected post run with an OBEY program which uses a correction factor curve generated relative to the NIST standard quinine sulphate spectrum or an NIST calibrated tungsten lamp. The spectra shown are the uncorrected and corrected emission spectra of protoporphyrin IX.
DEDICATED APPLICATIONS
Dedicated application routines are included for a variety of analyses. For example, measurement of intracellular ions with specific fluorescent probes can be made using the intracellular biochemistry, ICBC, software program. The method page of this program enables you to set up either an excitation or an emission measurement. Similarly, polarization spectra and phosphorescence lifetimes can be obtained through the application routines.
POLARIZATION
Fluorescence polarization is widely used in biological research to provide a valuable in sight into protein interactions and membrane mobility. Steady-state measurements and polarization scans are obtained with the standard polarization accessory. Rapid measurements every 40 msec can be obtained using the Fast Filter accessory. In both cases the Software automatically calculates the polarization and anisotropy values. This example shows the effect of cholesterol on the phase transition of dimiristoyl phosphatidyl lecithin (DML) deterimined by automatically measuring the fluorescence polarization of diphenylhexa-triene (DPH) - labelled DML vesicles incubated with increasing concentrations of added cholesterol.
FRONT SURFACE DETECTION
Solid samples such as thin films and powders or highly scattering samples are more conveniently analyzed by measuring the emission from the sample surface. This can easily be made using the optional Front Surface accessory. The example shows the phosphorescence emission spectrum and the decay curve from a sorting code phosphor imprinted on a postage stamp.
MEASURING MODES
The Model LS-50B uses a pulsed xenon lamp as an excitation source providing high sensitivity while minimizing photobleaching. Fluorescence is measured by synchronizing the data collection to the pulse. Phosphorescence is measured by selecting a user specified delay and sampling time together with a variable pulse rate. Bio- and chemiluminescence are measured by turning off the source and using extended integration times.
INSTRUMENT CONTROL
The menu driven software offers completely automated control of instrument function, applications and data management. Setting the pointer to INSTRUMENT reviews the menu for the various analytical modes and the computer controlled accessories. For example, TLC plates or gels can be scanned automatically by using the TLC PLATE command or 96-well microplates measured using the WELL PLATE command.
SCANNING SPECTRA
Selecting the SCAN dialog displays all of the analytical parameters associated with scanning the excitation and emission monochromators independently or synchronously. Selecting PRESCAN enables the automatic determination of the peak excitation and emission wavelength maxima between user defined limits. This dialog shows the parameters used to automatically collect constant energy synchronous spectra (CESM) to obtain a 3 Dimensional CESM matrix.
ENZYME KINETICS
Reaction rates can be monitored in four cuvettes in real time using the automated cell changer accessory. OBEY programs can customize data treatment, e.g. KINETICS.OY, calculates 1st order reaction parameters from time drive data. This program uses the algorithm F(t) = In (l(max) - l(t)) and calculates the reaction rate constant by linear regression.
STOPPED FLOW ANALYSIS
Very rapid changes in fluorescence data can be monitored using the fast data collection mode of the Model LS-50B. In this mode data are collected and displayed for every pulse. The effect of adding nicotine and histamine to FURA-loaded bovine adrenal chromaffin cells using a HI-TECH stopped flow apparatus illustrates this fast data collection mode and remote start capability.
96-WELL PLATE READER
The computer controlled plate reader is used either for Scanning TLC plates and gels or for measuring samples in 96-Well Microplates. Sensitivity, accuracy and non destructiveness are of paramount importance when quantitating small amounts of DNA amplified using the Cetus GeneAmp Polymerase Chain Reaction PCR process. The Hoechst dye 33258 is specific for DNA in the presence of protein and enables excellent detection limits to be achieved in 250 µL samples.