Perkin Elmer Lambda 800

ID-number: 016470
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Perkin Elmer UV/VIS-spectrophotometer Lambda 800. Double beam. 185-900 nm. 230 V. 50 Hz. 250 W. Software UVWinlab 3.00.02 Rev. A. Cuvette holder for 10x10 mm cuvettes. Dust protection.
siehe Storeview
More Information
Objektnummer B00016470
ID-number 016470
Object name Perkin Elmer Lambda 800
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Perkin Elmer

model:                   Lambda 800

annotation:           Dokumente engl.

Perkin-Elmer Lambda 800 UV-VIS Spectrophotometer

Lambda 800

Key Features

Unrivaled Benefits

Wavelength Scanning t0 175 nm

No additional option is required to scan below 185 nm (N 2 purging must be used)

High Sensitivity PMT

Gridless PMT design provides improved signal to noise in the UV region

Standard Sample and Reference Beam Attenuators

Included in basic instrument. No loss of sample compartment room.

Standard RS232 Interface

No computer compatibility problems

Technical Description and Specifications Lambda 800

Principle

Double beam, double monochromator, ratio

recording UV/Vis spectrophotometer vvith microcomputer electronics, controlled by DELL PC or compatible Personal Computer.

Optical System

All reflecting optical system (SiO 2 coated)

with holographic grating monochromator with

1440 Lines/mm UVNis blazed at 240 nm,

Littrow mounting, sample thickness

compensated detector optics.

Beam Splitting System

Chopper (46+ Hz, Cycle: Dark/Sampie/Dark/

Reference, Chopper Segment Signal Correction

CSSC).

Detector

Photomultiplier R6872 for high energy in the

whole UV/Vis wavelength range.

Source

Pre-aligned tungsten-halogen and deuterium.

Wavelength Range

(N 2 purge required below 185 nm)

175 nm-900 nm

UV/Vis Resolution

< 0.05 nm

Stray Light

At 200 nm (12 g/L KCI USP/DAP method)

At 220 nm (10 g/L Nal ASTM method)

At 340 nm (50 mg/L NaNO 2 ASTM method)

At 370 nm (50 mg/L NaNO 2 ASTM method)

> 2 A

< 0.00008 %T

< 0.00008 %T

< 0.00008 %T

Wavelength Accuracy

+/- 0.08 nm

Wavelength Reproducibility

UV/Vis (Deuterium Lamp Lines)

Standard deviation of 10 measurements UV/Vis

< 0.020 nm

< 0.005 nm

Photometric Accuracy

Double Aperture Method 1 A

Double Aperture Method 0.5 A

N IST 1930D Filters 2 A

NIST 930D Filters 1 A

NIST 930D Filters 0.5 A

K 2 Cr 2 0 7 -Solution USP/DAP method

+/- 0.0006 A

+/- 0.0003 A

+/- 0.003 A

+/- 0.003 A

+/- 0.002 A

+/- 0.010 A

Photometric Linearity

(Addition of filters UV/Vis at 546.1 -nm,

Slit 2 nm, 1-sec. Integration Time)

At 1.0 A

At 2.0 A

At 3.0 A

+/-0.001A

+/- 0.002 A

+/- 0.006 A

Photometric Reproducibility

1 A wich NIST 930D Filter at 546.1-nm

Standard Deviation for 10 measurements

0.5 A wich NIST 930D Filter at 546.1-nm

Standard Deviation for 10 measurements

0.3 A wich NIST 930D Filter at 546.1-nm

Standard Deviation for 10 measurements

(2-nm Slit, 1 -sec. Integration)

< 0.00016 A

< 0.00008 A

< 0.00008 A

Photometric Range

7 A (wich SRATT)

Photometric Display

Unlimited

Bandpass

0.05 nm-5.00 nm in 0.01 -nm increments

UV/Vis range

Fix resolution, constant energy or slit

programming.

Photometric Stability

(After warm-up at 500 nm, 0 A, 2-nm Slit,

2-sec. Integration Time, Peak to Peak)

< 0.0002 A/h

Baseline Flatness

(Lambda 900:190 nm-3100 nm, 2-nm Slit,

Gain 1 NIR, 0.20-sec. UV/Vis-0,24-sec.

NIR Integration Time, no smoothing applied)

(Lambda 800: 190 nm-860 nm, 2-nm Slit,

0.20-sec. Integration Time, no smoothing applied)

+/- 0.001 A

Photometrie Noise RMS

0A and 190 nm

0 A and 500 nm

2 A and 500 nm

4A and 500 nm

6 A and 500 nm

(2-nm Slit, 1-sec.Integration Time, Gain 1 NIR)

< 0.00010 A

< 0.00005 A

< 0.00020 A

< 0.00100 A

< 0.00500 A

Sample Compartment Instrument

(W x D x H)

200 mm x 300 mm x 220 mm

Purging

Optics

Sample Compartment

YES

YES

Instrument Dimension (W x D x H)

1020 mm x 630 mm x 300 mm

Instrument Weight

- 55 kg

Digital 1/0

RS 232 C

Light Beam

90 mm above the base plate

120 mm beam separation

3 mm-12 mm beam height

Instrument Requirements

Power

Temperature

Recommended Humidity

90VAC-250VAC,50/60 Hz; 400VA

10°C-35,C

10-70% relative humidity, non-condensing

Product group: Photometers / Spectrophotometers