Perkin Elmer FTIR 1725x
Objektnummer | B00018564 |
---|---|
ID-number | 018564 |
Object name | Perkin Elmer FTIR 1725x |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Kommentar: Dokumente engl. (für ID. 11180)
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Perkin Elmer FTIR-Spektrometer 1725 X
The Perkin-Elmer Model 1725X is a new benchtop FT-IR spectrometer controlled by an IBM® PC-AT, PS/2 or compatible computer. Equally at home in a routine analytical or research environment, the Model 1725X has optical and data handling facilities to match the most demanding applications. Stability and sensitivity levels are second to none, providing the most reliable results in the shortest time. In common with the other members of the 1700X Series, the optical unit is sealed and desiccated, removing the need to purge for most applications. Sample turnaround time is typically seconds rather than minutes.
The Infrared Data Manager and Instrument Control software packages use a mouse driven window environment to provide logical and user friendly interaction. Spectral SEARCH, quantitative analysis and macro-programming packages are also available. Data import and export facilities are provided using industry standards such as JCAMP-DX and Lotus® 1-2-3. These provide a gateway to a host of third-party software packages and network systems and ensure that the Model 1725X can be fully integrated into the computer controlled laboratory.
FEATURES
n Research level performance
Range, resolution and sensitivity levels normally associated with research spectrometers allow the Model 1725X to handle the most demanding applications.
n The PC advantage
PC control and data compatibility provide a link with the expanding world of industry standard hardware and software.
n Friendly, versatile software
A mouse-driven window software environment is ideal for both routine and research users.
n FuIIy upgradeable
The Model 1725X is compatible with every accessory and upgrade expected of a research level FT-IR spectrometer, including IR microscopy, GC-IR and external beam facilities.
The Model 1725X
Specifications
Principle:
1700X Michelson interferometer with frictionless electromagnetic drive and bidirectional data collection. Auto interferometer alignment.
Optics:
Multicoated KBr beamsplitter standard. Csl, near and far-IR beamsplitters available.
Sealed, desiccated optics. Purge possible but not an instrumental requirement.
Source:
Temperature stabilized ceramic, air cooled standard. QuartziHalogen available for the near-IR.
Detector:
Temperature stabilized, fast recovery DTGS standard. Wide, medium or narrow band MCT detector can be installed simultaneously with DTGS. Other near and far-IR detectors available.
Wavenumber range:
7900 370 cm -1 standard.
15,000 30 cm -1 with various near or far infrared options.
Resolution:
At least 2 cm -1 to 64 cm -1 standard. 0.5 cm -1 available.
Signal-to-noise:
>3000:1 p-p (15,000:1 RMS) in the region of 2000 cm -1 , 4 second measurement at 4 crn -1 resolution with DTGS detector.
Up to 30 times higher sensitivity with MCT under low energy conditions.
External beam:
Choice of parallel or focused beam, detectors and configuration of auxiliary bench available.
Scan speeds:
5 speeds between 0.1 and 2.0 cm.s -1 o.p.d. velocity.
Accessories:
Full range of IR sampling accessories. Infrared microscopes, GC-IR and TG-IR accessories. Photoacoustic detector. Sample shuttle for effective double beam Operation.
Size & Weight:
Optical unit
815 mm bong; 269 mm high 610 mm deep; 70 kg
Electronics unit
325 mm Jong; 269 mm high; 610 mm deep; 24 kg.
Power requirements:
200 to 240 V; 50 or 60 Hz
100 to 117 V; 50 or 60 Hz
250 VA
Data Handling
Data System:
IBM PC-AT, PS/2 or equivalent. Contact Perkin-Elmer for exact configuration.
Operating System:
Mouse-driven window environment operating under MS-DOS®.
Graphics:
EGA high resolution color graphics. Multiple spectra can be displayed and manipulated interactively.
Memory:
640 KByte RAM and 2 MByte extended memory.
Data storage:
Choice of floppy disks, Winchester drives and other PC compatible storage devices.
Hard copy output:
8-color single page plotter. Dot matrix printer.
Communications:
IEEE-488 or RS232C communication with spectrometer. Data import and export via JCAMP-DX and Lotus 1-2-3 format to most thirdparty software data handling and networking packages.
Software:
1700 instrument control and Infrared Data Manager (IRDM) are standard. Other infrared packages include:
OBEY macroprogramming package
PC SEARCH Expert spectral interpretation package
PC QUANT Least-squares multicomponent quantitative analysis.
Details of these software packages can be found in the relevant data sheets.