Perkin Elmer Autosystem ECD
| Objektnummer | B00017411 |
|---|---|
| ID-number | 017411 |
| Object name | Perkin Elmer Autosystem ECD |
| Status | Stock unit |
Product group: Gaschromatographs (ECD)
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Flexibilität
Kein anderes GC-System bietet diesen Grad an Flexibilität: von den völlig neuen Möglichkeiten des Autosamplers über die verschiedenen lnjektorsysteme und Detektoren bis hin zu einer Vielfalt an Datenverarbeitungs-Systemen. Gerade diese Flexibilität macht den AutoSystem GC zu einem Meilenstein auf dem Weg zu sicheren Analysenergebnissen.
Einfache Bedienung
Mit dem AutoSystem steuern Sie GC und Autosampler über eine Tastatur. Durch farblich abgesetzte Funktionstasten findet sich der Anwender leicht zurecht.
Zuverlässigkeit
Der AutoSystem GC setzt neue Maßstäbe für die Zuverlässigkeit eines GC-Gerätes. Das System wurde entwickelt im Hinblick auf den hohen Qualitätsstandard der anspruchsvollsten GC-Labors. Hohe Verfügbarkeit und leichte Wartung sind die Zielrichtung.
Der AutoSystem GC bedeutet einen Durchbruch auf dem Weg zum Meßplatz mit vollständig integriertem Probengeber. Für alle Laboratorien, die eine große Anzahl von anspruchsvollen Routineanalysen zu bearbeiten haben, ist der AutoSystem GC die Lösung.
Der voll integrierte Autosampler.
Der in den AutoSystem GC eingebaute Autosampler bietet Ihnen einen neuen Grad an Flexibilität. Unterschiedliche Proben erfordern unterschiedliche Aufgabebedingungen. Mit dem Autosampler des AutoSystem GCs haben Sie alle Parameter im Griff.
Alle wichtigen Vorgaben werden über eine Tastatur eingegeben. Das bedeutet Flexibilität, die Sie in der Hand haben und leicht handhaben. Sie werden kein anderes GC-System finden, das eine vergleichbare Vielfalt an Arbeitsmöglichkeiten bietet.
Der Autosampler beschickt beide Einspritzblöcke.
Das ermöglicht Ihnen, beide Kanäle des AutoSystem GC mit dem Autosampler zu betreiben. Sie können also Ihre Proben auf unterschiedliche Säulen aufgeben.
Drei Injektionsmodi.
Bei On-column-Aufgabe wird die Probe langsam, direkt auf die Säule gegeben. Normal ist die Standardaufgabegeschwindigkeit. Mit Fast wird die Probe sehr schnell aufgespritzt, um
bei weitsiedenden Gemischen Diskriminierung zu vermeiden.
Injektionsvolumen wählbar.
Die Injektionsvolumina sind über das Keyboard von 0.1 bis 5 m l wählbar.
Wenig Probe genügt.
Selbst wenn Sie nur 5 m l-Probe haben, können Sie davon noch 1 m l aufgeben.
Probenplatz mit Priorität.
Analysieren Sie die eilige Prioritätsprobe, ohne den laufenden Probenzyklus zu unterbrechen.
Vier Spül- und vier Abfallflaschen.
Diese Flaschen haben 4 ml Volumen. Damit ist eine mehrfache, gründliche Spülung möglich.
Optimale Steuerung des Probenflaschenbereiches.
Legen Sie den Probenflaschenbereich fest, aus dem injiziert werden soll, und der Autosampler findet das erste Fläschchen in der definierten Sequenz.
Selbständiger Start nach Stromausfall.
Der AutoSystem GC behält die Probensequenz nach Stromausfall bei und durchläuft einen Ausheizzyklus, bevor die nächste Probe aufgegeben wird.
Freier Zugang zu den Injektoren.
Gestattet manuelle Injektion und Routine-Wartung ohne Abnahme des Autosamplers.