Perkin Elmer AAS AAnalyst 800. With graphite furnace. Flame unit. PC. Software. All lamps available on request
siehe Storeview
More Information
Objektnummer B00025000
ID-number 025000
Object name Perkin Elmer AAnalyst 800
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer :       Perkin Elmer

model :                   AAnalyst 800

annotation :           Dokumente engl .

 

 

 

 

 

Technical data

 

Principle

Atomic absorption spectrometer.

Computer controlled, using a special application program running under a graphical user interface.

Real-time double-beam, all-reflecting optical system (single-path for

furnace operation).

Front-surfaced optics protected by a silica coating.

AC modulated spectral line sources.

 

Monochromator

Littrow configuration grating monochromator .

Grating:                        ruled area:                  64 mm x 72 mm, 1800 lines/mm

blaze wavelengths:    236 nm and 597 nm

Focal length:               267 mm

Slit widths                   0.2, 0.7 and 2.0 nm

Wavelength range:     190–870 nm

Reciprocal linear

dispersion :                  1.6 nm/mm (nominal)

 

Detector

Segmented discrete solid-state detector with CMOS charge amplifier array; software-controlled automatic gain control (AGC).

 

Lamps

Line radiation sources. Positions for up to 8 lamps in lamp compartment.

Single- and multi-element hollow cathode lamps ( HCLs ) and up to 4 electrodeless discharge lamps ( EDLs ) can be used.

 

Background correction

Continuum source (deuterium lamp) for the flame technique.

Inverse longitudinal Zeeman effect for the graphite furnace technique.

 

Atomizers

Flame atomization: Premix burner system with pneumatic nebulizer and interchangeable burner heads; automatic changeover between air/acetylene and nitrous oxide/acetylene flames.

Electrothermal atomization: Transversely-heated graphite furnace incorporating an electromagnet for longitudinal Zeeman-effect background correction.

 

Signal handling

Time average, peak average, peak height, peak area.

Measurement ranges:

absorbance :               –0.5 to 2.000

concentration :            0.00001 to 9999 concentration units

expansion factor:        0.01 to 100

read time:                   1 to 60 s

read delay:                  0 to 60 s

 

Calibration

Automatic zeroing, resloping , and recalibration.

Calibration/recalibration using up to 15 calibration solutions (‘standards’).

Calibration coefficients determined by a least squares procedure.

Analytical curve technique:

  • Linear with zero or non-zero intercept.
  • Non-linear, 2-coefficient, or 3-coefficient, zero or non-zero intercept.

Analyte addition technique:

  • Zero or non-zero intercept.
  • Additions calibrate (zero intercept).

 

Computer (minimum requirement)

PC with Intel Pentium processor, 16 MB RAM, CD-ROM drive.

Hard disk space: 30 MB minimum free for AA WinLab , Database and GPIB software, additional space required for storing results and methods.

Microsoft Windows 95 operating system.

Perkin Elmer offers a suitable PC for controlling the spectrometer system.

 

Application program

Special application program: AA WinLab .

Online help function.

Hard disk or floppy storage of measurement data, signals, and completed analytical methods.

Special Reporter, Reformatter , and Library Manager applications for generating data reports and reformatting data for export to other data handling programs.

 

Graphics

High resolution display of the signals.

Simultaneous display of the corrected analyte signal and the background signal.

Calibration curve display.

Storage and recall of transient absorbance signals.

Hard copy printout of screen graphics on an associated printer.

 

Power requirements

230 V single-phase, 50 Hz, power consumption 5000 VA,

-or-

240 V single-phase, 60 Hz, power consumption 5000 VA

 

Electrical protection

As defined in EN 61010-1-1993 (IEC 1010-1):

Insulation: Class I

Insulation category (overvoltage category): II

Pollution degree: 2

 

Safety standards

As defined in EN 61010-1-1993 (IEC 1010-1: 1990 + A1 + A2) and EN 61010-2-061:1996.

Compliant to the requirements of Canadian Standards Association (CSA) standards CAN/CSA-C22.2 No. 1010.1-92, Amendment 1 (1992), 2 (1995), and CAN/CSA 61010-2-061 (1995); File No. LR 45111.

Compliant to UL 3101-1 1993 and UL 3111-1 1994.

Certificate of Approval and GS mark from the LGA Bavaria, FRG, Institute of Equipment Safety Testing and Certification.

 

EMC standards

As defined in EN 61326-1:1997.

 

Environmental requirements

Ambient temperature: +15 °C to +35 °C,

20–80% relative humidity; non-condensing

 

Dimensions

Width:                         1095 mm        with handles:              1220 mm

Height:                655 mm        with door open:              865 mm

Depth:                700 mm        with handles:                 770 mm

with autosampler:      1040 mm

 

Mass (weight)

187 kg

Spectrometer alone, not including the computer, autosampler, and cooling

system .