Perkin Elmer AAnalyst 200
| Objektnummer | B00021872 |
|---|---|
| ID-number | 021872 |
| Object name | Perkin Elmer AAnalyst 200 |
| Status | Stock unit |
Product group: Atomic absorption spectrometers (flame)
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
model: AAnalyst 200
annotation: Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

Control and Data System
User Interface
Complete control of the AAnalyst TM 200 through an innovative touch-screen interface. Flexible software for lamp setup, flame control, parameter selection and sample analysis. The tools menu provides access to recommended conditions, sample information, method storage and recall, data transfer and service diagnostics screens. The AAnalyst 200 supports multiple languages, including Spanish, English, French, Russian, Japanese, German, Italian, Portuguese (Brazilian), Polish, Greek and Chinese.
Display
Full-color 10.4 LCD touch screen. VGA resolution (640 x 480 pixels). Coated for maximum durability and lifetime.
Data Handling
The parameters page is used for setting up the analysis. Users can select up to eight calibration standards or a reslope standard and choose from seven different calibration algorithms. Integration times are operator-selectable from 0.1 to 60 sec. Print choices include method, replicates and calibration curve. Signal measurement modes include time-averaged integration, manual continuous graphics and peak-height measurement. An optional footswitch to trigger a read is also available.
Sample Analysis
The sample-analysis page is used for manual or automated analysis. All results are displayed on the screen. Separate buttons for blank, standards and samples allow for easy analysis. Sample ID and dilution factor are available on this page as entered in the tools/sample information menus. The calibration curve can be displayed and printed with correlation coefficient, slope and intercept. Peaks can be displayed and printed when using the MHS-15 accessory.
Accessories
Automated analysis can be performed with a PerkinElmer ® autosampler and the sample information tool. The MHS-15 can be used for the determination of hydride-forming elements and mercury.
Hardware
System
True double-beam echelle optical system. Front surfaced, reflecting optics with protective coating. Deuterium background corrector and built-in EDL power supply available on some models.
Optical System
Echelle monochromator. Focal length: 300 mm. Grating: 36 x 185 mm area, 79 lines/mm, blaze angle 76 ˚ . Fused-quartz prism: 95 x 40 mm, 60 ˚ . Wavelength range: 189-900 nm. Spectral bandpass: 0.15 nm at 200 nm. Reciprocal linear dispersion: 2.4 nm/mm. The photometer optics are covered to protect against dust and corrosive vapors. For maximum protection, the optical system can be purged with an inert gas.
Detector
High-efficiency, segmented solid-state detector.
Light Sources
Hollow cathode lamps (HCLs) and electrodeless discharge lamps (EDLs). EDLs provide much higher light output and longer lifetime when compared to conventional HCLs. Lamp elements, recommended operating currents and slit selection are automatically recognized and set when using PerkinElmer Lumina TM series AA lamps. Lamp alignment is completely automatic in models with a four-lamp turret.
Electronics
Processor
Internal 300 MHz GX1 with 64 Mbytes of DRAM and 128 Mbytes of flash program memory on a PC104 interface-style printed circuit board. Includes real-time clock.
Graphics
32-bit controller on PC104 board.
Ports
RS232 C, 9-pin, parallel printer and 10BaseT Ethernet on some models.
E-box
All electronics are located in a single user-replaceable module. The operator can just slide the module out from the front of the instrument and replace it with a new one. Instrument operators can replace most parts quickly and easily without a service visit.
Gas Controls and Burner System
Flame Gas
Fully automated gas box with computer-controlled oxidant selection with automatic gas sequencing, oxidant and fuel monitoring and control.
Control
Touch-screen actuated ignition with air/acetylene. Acetylene flow is automatically adjusted when switching to or from nitrous-oxide/acetylene operation.
Flame Safety Features
Fully interlocked operation prevents ignition if the proper burner head, the nebulizer, end cap or burner drain system is not correctly installed, the level of the liquid in the drain vessel is incorrect, or gas pressures are too low. Interlocks will automatically shut down the gasses if a flame is not detected. The flame is automatically and safely extinguished in the event of a power failure or when the emergency flame-off button is used.
Burner System
An inert polymer mixing chamber provides superior analysis of corrosive and high-solid matrices. The spray chamber is manufactured from a high-strength composite, eliminating the need for pressure-relief devices. The high-precision inert nebulizer maximizes stability and sensitivity.
A 10-cm single-slot solid titanium burner head for air/acetylene operation is included. Optional burner heads include: 5-cm nitrous-oxide/acetylene, 10-cm 3-slot air/acetylene and 5-cm single-slot air/acetylene.
Sample Area
25 cm wide x 25 cm deep sample compartment for easy access to burner components.
System Specifications
Dimensions
70 cm wide x 65 cm deep (0.46 m 2 ) x 65 cm high
Weight
49 kg
Power
100-230 V (±10%), 50/60 Hz (±1%), 300 VA (maximum)
Technical
Classified as a laboratory instrument. Complies with the applicable European Union directives and standards for safety and electromagnetic compatibility for CE Marking, the safety requirements for
Environmental
Dust-free, free of vibrations, ambient temperatures: +15 ˚ C to +35 ˚ C with a change rate of a maximum 3 ˚ C per hour. Relative humidity: 20% to 80% non-condensing.