Perkin Elmer AAnalyst 100
| Objektnummer | B00017136 |
|---|---|
| ID-number | 017136 |
| Object name | Perkin Elmer AAnalyst 100 |
| Status | Stock unit |
Product group: Atomic absorption spectrometers (graphite furnace)
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Figure 1-1. The AAnalyst 100 Atomic Absorption Spectrometer.
The AAnalyst 100 Atomic Absorption Spectrometer is designed for use
with flame absorption, flame emission, graphite furnace, and mercury/hydride atomic absorption techniques.
The AAnalyst 100 offers a high efficiency burner system using an adjustable Universal GemTip corrosion-resistant, plastic nebulizer for general, all-round use where a wide variety of sample types is analyzed. The optional High Sensitivity GemTip nebulizer is available for those applications requiring the utmost in sensitivity and detection limits.
Built-in gas controls with safety interlocks, automatic ignition button on the keypad, and automatic switching from an air-acetylene flame to a nitrous oxideacetylene flame, simplify operation while insuring operator safety.
A built-in control panel, with a two-line alphanumeric display, a numeric keypad, and function keys, is used to access the comprehensive programming which is embedded in the built-in microprocessor.
The AAnalyst 100 Atomic Absorption Spectrometer is a double-beam atomic absorption spectrometer for flame, graphite furnace and mercury/hydride analysis. lt is a sophisticated analytical system capable of performing automated single element determinations. The basic instrument is designed for use with flame absorption and flame emission techniques. It can be upgraded to be used with graphite furnace and mercury/hydride atomic absorption techniques as analytical requirements change.
Spectrometer Portion Description
The spectrometer portion of the instrument provides a means of measuring light at a specific wavelength. To perform this function, the spectrometer uses a primary light source, monochromator optics, and a detector.
The primary light source, either a hollow cathode lamp or an electrodeless discharge lamp, is placed in the spectrometer to emit the narrow atomic lines of the element to be determined. The light from the lamp is optically chopped and passed alternately through and around the flame. When the light passes through the sample compartment, a portion of it is absorbed by the atomized sample. The beams are then recombined and travel through to the monochromator.
The monochromator optics disperse the various wavelengths of light and isolates the particular line of interest. A dual-blazed grating is used, which provides optimized performance over the entire atomic absorption wavelength.
The light leaving the monochromator is directed onto the detector, a photomultiplier tube (PMT), which produces an electrical signal proportional to the light intensity. The electrical signal is amplified and processed to produce a signal which is a measure of the light attenuation (i.e. absorbed) occurring in the sample compartment.