Perkin Elmer 2380
| Objektnummer | B00000611 |
|---|---|
| ID-number | 000611 |
| Object name | Perkin Elmer 2380 |
| Status | Stock unit |
Product group: Atomic absorption spectrometers (flame)
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Some of the outstanding features of the Model 2380 include:
Double-beam optical system with high-dispersion monochromator
Two Sets of slits for optimal performance with flame or graphite furnace sampling
Microcomputer electronics allows minimum keystroke operation
Full four-digit readout
Automatic Gain Control
Automatic resloping at the push of one button
Measurements in peak height or peak area
Automatic calibration with 1, 2 or 3 standards
Scale expansion continuously variable from 0.01 X to 100 X
New burner chamber accommodates flow spoiler or impact bead
Integration time continuously variable from 0.2to 60 seconds in 0.1-second intervals
Statistics package which includes average, standard deviation and coefficient of variation
Built-in interlocked gas controls with burner head safety interlock, automatic nitrous oxide switching with acetylene boost and remote flame ignition
Double-beam Deuterium Arc Background Corrector with BG ONLY mode selection
Optional microprocessor-controlled burner control allows automatic ignition of air-acetylene or nitrous oxide-acetylene flames; digital flow settings, burner head and drain interlocks, flame sensor and flow-ratio monitoring are built-in
The Model 2380 is a double-beam, microcomputer-controlled atomic absorption spectrophotometer. The 2380 uses a high-dispersion monochromator with a dual-blazed grating and high-performance photomultiplier for maximum energy throughput over the wavelength range from 190 to 870 nm. Two sets of slits (NORMAL and ALTernate) provide optimum performance with both flame and flameless techniques.
MICR0C0MPUTER-CONTROLLED CONCENTRATION READOUT
The 2380 reads out directly in concentration an a built-in digital display with a range of ± 9999 counts. The built-in microcomputer permits automatic calibration an the display with one, two or three standards. To calibrate the 2380, simply enter the desired value with the numerical keyboard and push the button for the approphate standard (S1, S2 or S3). The calibration value is automatically stored in memory. Next, aspirate each standard in sequence and press the appropriate standard button. Calibration is equally easy for atomic absorption or flame emission, flame or flameless sampling. To recalibrate in the middle of the run, analyze a single standard and press the reslope (RSLP) key.
The Model 2380 has built-in averaging to improve the accuracy of your analysis. Also available in the statistics package are standard deviation and coefficient of variation. For printed results, the Model 2380 can be connected directly to the accessory PRS-10 Printer-Sequencer or the accessory TR-2 Teletypewriter Readout. There is also an optional communications interface which provides an EIA, RS-232C-type of output.
Integrated readings may be taken continuously or held an the display. Peak height and peak area measurements are also available. Integration times are continously variable in 0.1-second intervals from 0.2 to 60 seconds. Scale expansion is continuously variable from 0.01 X to 100 X.
BURNER AND GAS CONTROLS
The burner system an the Model 2380 consists of the new Perkin-Eimer premix design burner chamber. The chamber is made of a highly resistant material, Ryton, and is internally coated with polypropylene for maximum corrosionresistance. It can accommodate a flow spoiler or an impact bead to provide improved detection limits whether using air-acetylene or nitrous oxide-acetylene flames.
A 10-cm, single-slot, all-titanium burner head and a stainess steel adjustable nebulizer are standard equipment with the Model 2380. Interlocked gas controls are built into the Model 2380.
There are pressure regulators and flow meters for fuel and oxidant and a three-way valve to switch between air and nitrous oxide. To switch over to the nitrous oxide-acetylene flame, turn the valve to nitrous oxide, and if the nitrous oxide burner head is in place, the acetylene flow will be increased automatically and nitrous oxide will flow. If the nitrous oxide burner head is not in place, the air-acetylene flame keeps burning. Naturally, both fuel and oxidant may be shut down at the instrument.
An optional microcomputer gas control system is also available for the Model 2380. It is programmed to control ignition and shut-off of the air-acetylene and the nitrous oxide-acetylene flames in the proper sequence. It also has burner head and drain interlocks, checks if the flow ratio you have selected will allow safe operation and displays the gas flows an digital readouts. Sensors watch the Flame and gas pressures and turn off the gases in proper sequence if there
is a pressure drop, power failure or if the Flame is extinguished. The 2380 may be used for atomic absorption or flame emission measurements. When the instrument is used in the atomic absorption mode, the built-in Automatic Gain Control sets and maintains the proper photomultiplier gain throughout the analysis. When the optional Deuterium Arc Background Corrector is used, Automatic Intensity Control adjusts the power to the deuterium arc to maintain an optimized intensity relative to that of the primary source, whether an Intensitron Hollow Cathode Lamp or a Perkin-Eimer Electrodeless Discharge Lamp (U.S. Patent Number 3,873,884) is being used.
SPECIFICATIONS - MODEL 2380
Monochromator: Littrow grating system. Focal length 267 mm. Wavelength range 190-870 nm, covered by dual-blazed grating, 1800 lines/mm (45,700 lines/inch). Ruled area 64 x 72 mm, blazed at 236 nm and 597 nm. Resolution settings of 0.2, 0.7 and 2 nm, switch selectable. (NORMAL slits for Flame work and ALTernate slits for graphite furnace work.) Dispersion: 1.6 nm/mm (nominal). Wide-range photomultiplier detector with UV-transmitting windows. Wavelength read in nm an three-digit counter.
Photometer: Double-beam, time-shared system. "AC" system (lamp light modulated by rotating chopper while flame light is unmodulated). Minimum spectral bandwith, 0.2 nm (nominal). Source current adjustable to 40 ma. Front-surfaced, reflecting optics with protective coating for improved ultraviolet reflectivity.
Readout: Results shown an a four-digit electronic display with polarity indication and adjustable decimal. Absorbance readings from 0.5 to 2.000 A; concentration readings to 9999 with continuously variable scale expansion of 0.01 X to 100 X. Automatic zero setting and automatic concentration calibration (with up to three standards) are push-button actuated. Integration time variable from 0.2 to 60 seconds in nominal 0.1-second intervals. Built-in ability to take a number of readings, average them and display the average, and to calculate and display the coefficient of variation and standard deviation. Reslope of the calibration with a single additional standard is built-in. Informative error messages are displayed to alert the analyst of improper instrument calibration. Peak height and integrated peak area modes are provided for use with fast peak-shaped signals. Overrange indication for expansion, calibration, absorbance and display. Function indicator and display checks in LAMP and SET UP modes. Direct connection provided for laboratory recorder with separate recorder control allowing continuous or integrated readings an recorder (per the digital display), continuous readings in absorbance or continuous readings with display calibration and three different time constants. Compatible with PRS-10 Printer-Sequencer and TR-2 Teletypewriter systems. Optional communications interface provides EIA, RS-232C-type of output.
Deuterium Background Corrector (Optional): Internally mounted unit with controls mounted in lamp compartment and easily accessible. Provides simultaneous correction for molecular absorption and light-scattering. Deuterium arc lamp used as continuum source for increased intensity and broader wavelength coverage relative to hollow cathode lamp-type continuum sources. Power switch activates Automatic Intensity Control circuitry which automatically adjusts the power to the lamp to provide the approphate lamp intensity. Rotary switch allows selection of AA (background corrector off), AA-BG (AA simultaneously corrected for background absorption), BG (AA-BG operation but energy display Shows background energy) and SG ONLY (hollow cathode lamp off) monitored an Lamp/Energy display (two-digit LED display).
Sample Area: 22.5 cm wide, 21 cm deep. Open to the front through a removable flame shield with about 7% light transmission. Sample tray, 21 cm wide and 12 cm deep, adjustable to three separate heights.
Wavelength Drive: (Optional Module) 5 nm/min scan speed. Burner: Premix design with Ryton (highly resistant material) mixing chamber internally coated with polypropylene. Accommodates plastic-coated flow spoiler or impact bead. Angled to ensure proper drainage. Auxiliary air inlet. Burner mount is adjustable in vertical, horizontal, and angular directions. Adjustable stainless steel nebulizer (corrosion-resistant nebulizers are available); 10-cm, single-slot, all-titanium burner supplied.
Standard Flame Gas Controls: Interlocked gas controls containing individual flow controls and meters for oxidant and fuel. T-valve to switch oxidant from air to nitrous oxide. Flame is ignited only an airbased flames with push-button actuated glow plug. Also contains burner head safety interlock system and automatic fuel change when switching to a nitrous oxide-acetylene flame.
Optional Flame Gas Controls: Includes microprocessor to measure oxidant and fuel flows, to provide automatic checking for safe flow ratio, and to sense burner head, pressure, flame and burner drain. Also includes automatic gas sequencing in addition to the features of the standard burner Control.
Weight: 70 Kg (150 Ib) net; 125 Kg (2701b) gross.
Power Requirements: 105-125 or 200-240 volts, 50/60 Hz, 150 watts.
Dimensions: 54 cm high overall, 45 cm high without flame shield; 50 cm deep; 88 cm wide.