Archive

Parr 4842

ID-number: 016849
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Parr Pressure reactor 4842. 345 bar. 425°C. 1,8 L. On Table.
siehe Storeview
More Information
Objektnummer B00016849
ID-number 016849
Object name Parr 4842
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Parr

model:                   4842

annotation:           Dokumente engl.

New Resilient Graphite Gaskets

All Parr HP/HT Reactors are equipped with flat, Grafoil gaskets held in confined gasket grooves with minimum exposure to the reactants. These gaskets are made of a flexible form of graphite which will withstand high temperatures up to the limits prescribed for these vessels, and they will not flow under high temperatures and pressures. They offer excellent resistance to a broad range of corro­sive environments, including oxidiz­ing atmospheres, and under most operating conditions they are reusa­ble. Replacements are relatively inex­pensive and easily installed.

For users who prefer metal gaskets, Parr HP/HT Reactors can be fur­nished with a metal head gasket in a self-sealing, diamond design. These gaskets are usually made of stainless steel, but they can also be made of other alloys. Metal gaskets must be used with great care to protect the faces of the metal-to-metal seal, but with proper maintenance and care, satisfactory high pressure seals can be developed and maintained. An indi­vidual gasket can usually be reused 20 to 30 times before it becomes deformed to the point where it is no longer usable.

Optional Cylinder Openings

All of the floor stand reactors in this HP/HT Series are designed so that either one or two additional connec­tions can be made into the bomb through the top flange on the side of the cylinder without mterfering with the Split ring closure. High pressure tubing is then used for connections to the control panel. It also is possible to offer an opening in the bottom of the vessel for a bottom drain, provided that a suitable valve can be obtained that will be compatible with the reac­tants and the temperatures and pres­sures to which it will be exposed. These optional connections, if required, must be described fully when ordering.

High Torque Magnetie Drives

Sealed magnetic drives in these new reactors ensure positive, leck-prool stirring without the problems whiel. can arise with gland-type seals at higt temperatures and pressures. ThE high coupling torque provided by these heavy duty drives will handlc most stirring loads. If necessary, e double reduction drive System can bE added for use with extremely viscou„ mixtures. Water cooling sleeves arE provided to protect the componenü from high operating temperatures.

Positive Agitation

There are two, six-blade, downward thrust impellers on the stirrer shaft in these reactors, both adjustable on the shaft. In their usual positions the bot­tom impeller serves to keep particles in suspension while the upper impeller is set at the base of the gas-liquid vor­tex to entrain gases into the liquid phase. A guide bearing attached to the thermowell helps to stabilize the shaft.


Controler 4842

Principal Features

- Digital display

- Digital setpoint

- Three term (PID) control

- High temperature cutout

- Microprocessor based system

Enhancement Opitons

- Tachometer Display Module

- Pessure Display Module

- High Temperature Cutoff Module

- RS232C Communications Module

- Solenoid Valve Module

- Ammeter Display Module

- Analog Outputs

The 4842 Controller is a fall feature, microprocessor based, fully digital temperature control system offering adjustable proportional, integral and derivative (PID) action with which the user can tune the controller to a wide range of operating conditions. All con­trol and tuning settings are entered an a front panel keypad while an alpha­numeric vacuum fluorescent display prompts the Operator step-by-step for all setting and tuning operations. Security key Codes prevent unautho­rized changes.

A 25 amp, solid state relay is included to handle the heater load, and variable speed control is provided for the reactor motor. Any three of the listed Enhancement Options can be added to the 4842 Controller.

Protection against runaway temper­atures is provided by a setable high temperature limit, the same as de­scribed for the 4841 Controller. There is also an Output socket for an aux­iliary cooling system. An optional dedicated communications board can be added to the 4842 Controller to allow all actions to be reported via any RS232C, RS422 or 20mA current loop. Battery backup is provided for the controller memory.

Specifications

Input thermocouple                      Type J

Operating range                           0° to 600° C

Readout resolution                       1°C

Setpoint resolution                       1°C

System accuracy                         +/-2°C

control action                               Three term PID control plus limit control

Operating voltages                       115 v and 230 v.a.c.

Maximum switching load             15 amp

Cabinet dimensions Overall        103/4" wide x 10" high x 12" deep

Product group: Mixers / Kneaders / Reactors