Oxford X-Met 3000 TX
Objektnummer | B00013691 |
---|---|
ID-number | 013691 |
Object name | Oxford X-Met 3000 TX |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Oxford
model: X-Met 3000 TX
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Probe
The excitation source in the X-Met3000TX is in X-ray tube. The standard target material is Silver. The probe contains a high resolution Si-PIN diode detector with Peltier cooling.
PDA computer
The removable PDA Computer in the X-MET includes the user interface for operat ng the Instrument. The computer is installed in the cradle of the instrument. The display is a 320x240-pixel color touch screen, which can be operated either with a fingertip or the stylus provided. For further information about the computer refer to the HP iPAQ 2210 instruction guide. The guide can be found with the CD delivered with the instrument.
Operating conditions of the X-MET3000TX
Temperature
Probe -10...50 °C
Charger -10...45 °C, operating
-40...70 °C, non-operating
Humidity
Continuous Operation at 20...95 % RH, no condensation. The charger is designed for
indoor use only.
Shock resistance
In transport and operation the Instrument must not be dropped or left in exceptional
conditions, which might damage its sensitive components.
During the measurement, small vibrations may Iead to inaccuracies if the vibrations
influence the detector.
Line voltage
Probe 90 — 240 V, 50 — 60 Hz.
PDA 100 — 240 V, 50 — 60 Hz
Charger 85 - 265 V, 47 - 63 Hz
Battery power
The X-MET batteries are situated inside the handle. To remove the battery, push the switch and pull to remove the battery. Each fully charged battery will operate the X-MET for approximately 4 hours.
Line (NC) power
Line operation of the X-MET is possible by connecting the AC adaptor to the instrument. To do this, remove the battery and connect the AC adaptor to the plug in the bottom of the handle.
Charger
The battery charger is provided for charging X-MET batteries. To charge a battery, remove it from the X-MET and connect the battery to the charger. Charging the X-MET batteries can take up to 2 hours if they are fully discharged.
Also, the PDA has internal batteries. Be sure to fully charge the PDA batteries using the iPAQ AC adapter prior to using the instrument for the first time. The PDA draws power both from the X-MET battery and its internal battery, but will not charge frorn the X-MET battery.
Hot Surface Adapter
The hot surface adapter is a standard feature of the X-MET3000TX. lt is designed for measurement at hot surfaces like hot tubes or plates. The adapter lowers the heat conduction and radiation from the hot sample to the detector. This is necessary because the detector crystal has to be cooled and stabilized to maintain its analytical performance. However, the heat conduction can not be prevented completely, thus there are limitations an the measurement times. Table 1 illustrates the limitations — surface ternperatures with measurement and cooling times between measurements.
Sample Temperature |
Measurement time |
Cooling time between measurements |
300°C |
15s |
10 min |
300°C |
5 s |
5 min |