Nova Biomedical electrolyte analyzer Stat Profile Prime.
Parameters Na, K, Cl, ionized Ca and Mg.
Accessories:
Printer rolls, rinsing syringe, blood collection device/change set. Hose/adapter system.
Without cartridge and sensor card.
More Information
Objektnummer B00044755
ID-number 44755
Object name Nova State Profile Prime ES
Year of construction 2020
Manufacture Nova
Shipping 4-6 weeks
Status Provider

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Nova

Modell:            Bioprofile 200

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

Two Multi-Test Analyzers

Provide Fast, Easy Measurements

BioProfile analyzers are fully automated, multi-test systems designed for the rapid analysis of key nutrients, metabolites, and gases in cell culture media.

Features of the BioProfile include:

• Up to twelve key parameters simultaneously measured including: glutamine, glutamate, glucose, lactate, pH, pO 2 , pCO 2 , ammonium, sodium, potassium, calcium, and cell density.

• All results available in as little as 2 minutes

• Automatic one-button operation

• 0.5 mL sample size

• Direct sampling from syringes, tubes, flasks, and pipettes

• No sample dilution or centrifugation

• Automatic analyzer calibration

Two Test Menus

The BioProfile test menus provide those assays necessary to address the testing requirements of research and development laboratories, and pilot production facilities. Developed in conjunction with leading biotechnology companies, these test menus enable control of the most critical constitu­ents of cell culture media.

Applications of the BioProfile include:

• Monitoring the progress of bioreactor runs

• Determining the consumption and production rates of key metabolites

• Identification of growth-limiting nutrients

• Design of cell culture feeding strategies

• Calibration of bioreactor probes

• Measurement of cellular respiration

• Balancing media electrolytes

• Controlling levels of waste products

Fast, Comprehensive Testing Gives

Real-Time Results and Reduces Costs

BioProfile's comprehensive test menus allow con­solidation of testing in a single analyzer. This results in significant time and labor savings, as well as real-time process control capabilities. As shown below, BioProfile analyzers can replace up to seven differ­ent instruments and measurement techniques.

BioProfile's fast analysis time and consolidated testing:

Eliminates the requirement for taking multiple samples and large sample volumes from reactor vessels

• Provides real-time access to test results, enabling real-time process control

• Decreases labor, capital equipment, and reagent costs by 75%

• Improves the ability to effectively monitor and control bioreactor processes

• Improves process reliability and reproducibility

• Speeds optimization of cell culture feeding strategies

• Improves manufacturing yield and quality

Instrument Specifications

Measurement Range:                      Na +                             40 - 220 mmol/L

                                                        K +                               1.0 - 25.0 mmol/L

                                                        ICa                              0.2 - 10 mmol/L

                                                        NH 4 +                           0.2 - 25 mmol/L

                                                        PH                              5.00 - 8.00

                                                        P CO 2                         3.0 - 300 mmHg

                                                        P O 2                            0 - 800 mmHg

                                                        Glucose                      0.2 - 15.0 g/L

                                                        Lactate                       0.2 - 5.0 g/L

                                                        Glutamine                   0.2 - 6.0 mmol/L

                                                        Glutamate                  0.2 - 6.0 mmol/L

Measuring Technology:                    Ion Selective Electrodes (Na + , K + , iCa, NH 4 + , pH, P CO 2 )

                                                        Amperometry ( P O 2 , Glucose, Lactate, Glutamine,     Glutamate)

Analysis Rate:                                  Mode                         Analysis Time        Throughput Time

                                                        Single Mode               3.9 minutes             4.2 minutes

                                                        Normal Mode             1.9 minutes             2.2 minutes

                                                        •    Analysis time measures how long the analyzer takes togive results.

                                                        •    Throughput includes washout time and measures how long it takes before the analyzer is ready for the next sample.

Sample Volume:                              500 microliters

Barometer:                                       450 - 800 ± 2 mmHg

Reagents:                                        A single reagent pack contains all fluids for 300 samples

                                                        (2700 tests)

Slope Limits:                                    pH                               9.1 - 11.2

                                                        P O 2                            -15.0 - (-1.6)

                                                        P CO 2                         7.9 - 12.2

                                                        Na +                             8.8 - 10.7

                                                        K +                               8.6 - 10.9

                                                        ICa                              8.9 - 13.0

                                                        NH 4 +                           8.6 - 14.0

                                                        Gluc                            5 - 50

                                                        Lac                             6 - 80

                                                        Gln                              5 - 60

                                                        Glu                              5 – 60

Analytical Specifications for Imprecision

Analyte            Within-run                                                 Day-to-Day

                        Precision                                                  Precision

                        n=20                                                           n=20

                        Whichever is Greater                                 Whichever is Greater

                        CV%               SD                                        CV%                 SD

PH                                          0.005                                                            0.018

P CO 2               5.0                  1.0 (mmHg)                          7.0                    2.8 (mmHg)

P O 2                  5.0                  1.5 (mmHg)                          7.0                    4.2 (mmHg)

Na +                   1.5                  1.0 (mmol/L)                        2.1                    1.4 (mmol/L)

K +                     3.0                  0.15 (mmol/L)                      4.2                    0.21 (mmol/L)

ICa                    4.0                  0.05 (mmol/L)                      5.6                    0.07 (mmol/L)

NH 4 +                 5.0                  0.10 (mmol/L)                      7.0                    0.14 (mmol/L)

Gluc                  5.0                  0.03 (g/L)                              7.0                    0.07 (g/L)

Lac                   5.0                  0.03 (g/L)                              7.0                    0.07 (g/L)

Gln                    5.0                  0.10 (mmol/L)                      7.0                    0.14 (mmol/L)

Glu                    5.0                  0.10 (mmol/L)                      7.0                    0.14 (mmol/L)

Calibration Gases:                           The 2 gas cylinders are “E” size and contain gases as         follows:

                                                        Gas Standard A        Specified Value            Accuracy

                                                        Carbon Dioxide          5.0%                               ± 0.03%

                                                        Oxygen                       20.0%                             ± 0.03%

                                                        Nitrogen                      Balance                          —

                                                        Gas Standard B       Specified Value            Accuracy

                                                        Carbon Dioxide          10.0 %                            ± 0.03%

                                                        Nitrogen                      Balance                          —

Electrical Compliance:                     To meet UL and CSA standards

Temperature Thermostatting:          37°C ± 0.1°C

Dimensions:                                     Height:     18.75 in (46.1 cm)

                                                        Width:      22.25 in (56.5 cm)

                                                        Depth:     23 in (58.4 cm)

Weight:                                             70 lb (52.38 kg) without reagent pack

Power:                                              90-264 VAC, 50/60 Hz, 200W