Sold

Nova Phox Plus

ID-number: 017442
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Nova Biomedical Bloodgas analyzer Stat Profile pHOx-Plus.
Quotation
siehe Storeview
More Information
Objektnummer B00017442
ID-number 017442
Object name Nova Phox Plus
Status Stock unit

Product group: Blood gas analyzer

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Nova

model :                   Phox plus

annotation :           Dokumente engl.

 

 

 

Using a unique combination of advanced optical and electrode technology, the Stat Profile pHOx series analyzers offer essential blood gas and critical care test menus in the smallest analyzers currently available in the industry. The three test Stat Profile pHOx Basic offers the standard blood gas profile of pH, PCO2 and PO2. The six test Stat Profile pHOx menu adds measured hematocrit, hemoglobin and oxygen saturation to provide a complete picture of lung function and oxygen status.

Stat Profile pHOx Plus adds glucose, sodium, potassium, and a choice of chloride or ionized calcium, resulting in an ideal critical care menu in a small, space-saving instrument. Stat Profile pHOx Plus C offers both chloride and ionized calcium. Stat Profile pHOx Plus L menu adds lactate.

 

Small size – big output

Stat Profile pHOx analyzers measure only 12" wide x 12" deep x 15" high, and are light enough for easy transport on a compact cart. But don’t let their small size fool you. Stat Profile pHOx analyzers carry enough on-board reagents to perform 7500 tests and contain a full month's supply of controls

 

All liquid calibration system

A new, liquid only calibration system eliminates bulky gas tanks, gas regulators, gas tubing lines, and humidifiers. A single reagent pack contains all calibrators. This integrated gas and reagent package system replaces up to five individual reagent bottles and two gas tanks with a simple, snap-in reagent package. The single reagent pack also eliminates the need to maintain logs and run both calibration and QC procedures each time one of the bottles or tanks needs to be replaced

 

On board – automated cartridge QC

Nova's auto-cartridge QC is a totally automated quality control system contained within a single on-board control cartridge. This unique system combines multiple levels of controls and dedicated software allowing any level of quality control to be run at any time — either on a pre-programmed schedule or on demand. This system dramatically lowers costs by reducing the time and labor required to manually perform quality control.

 

Samll sample volume

Blood conservation is an important initiative in every critical care department, especially the NICU. Stat Profile pHOx analyzer sample volumes are among the smallest in the industry.

 

Fast stat results

All test results from Stat Profile pHOx analyzers are available within less than a minute.

 

Remote control

The remote control function allows complete control of remote analyzers from Nova’s Point-of-Care Manager (PDM) workstation. The analyzer status can be reviewed and, if needed, analyzer calibration, maintenance and on-board QC testing can be initiated remotely. It also allows for any test to be enabled or disabled, or operator passwords to be enabled or disabled.

 

Connectivity and process automation

Complete process automation begins with the placement of Stat Profile pHOx analyzers at any point-of-care location. An unlimited number of analyzers can be interfaced with the Nova Point-of-Care Manager (PDM) located in the central laboratory which is in turn interfaced with the LIS. The point-of-care system:

Automates creation of test orders and accession numbers

Automates data entry of test results

Enables remote review of test results by the central laboratory

Interfaces to the LIS and HIS for complete data capture

 

Adapts to capillary or syringe use

Stat Profile pHOx analyzers weigh less than 20 pounds (9 kg) and are easily transported on the optional pHOx Cart with an uninterruptible power supply (UPS).

The Stat Profile pHOx sampler is designed for fast, easy use and operator safety using syringe or capillary samples. For samples in syringes, the sampling probe automatically positions itself at the optimal angle. For capillary samples, the sampler automatically presents a universal capillary sampling port in a horizontal position to prevent spillage or dripping.

 

 


 

 

 

 

 

1 Display

2 Keypad

3 Printer

4 Sampler

5 Door/Front Panel

 


 


1 Waste Line

2 Reference Line

3 Pinch Valve (Reference)

4 Pump and Pump Tubing

5 Reagent Pack Opening

6 Control Pack Opening

7 Sampler

8 Air Detector

9 Sensor Module With Sensors

10 Reference Electrode

11 Pinch Valve (Waste)

 


Stift Profile pHOx Plus Specificotions*

Measurement Range :              pH          6.50 - 8.00                 H + 316.23 - 10.00 nmol/L

PCO 2    3.0 - 200 mmHg     0.4 - 26.7 kPa

PO 2      0 - 800 mmHg         0.0 - 106.7 kPa

SO 2      30.0 - 100 %

Na +       80 - 200 mmol/L

K +           1.0 - 20.0 mmol/L

Cl -           50 - 200 mmol/L

Ca ++       0.1 - 2.7 mmol/L          0.4 - 10.8 mg/ dL

Glu          15 - 500 mg/ dL             0.83 - 27.75 mmol/L

Hct       12% - 70%

Hb           4.0 - 24.0 g/dL                   2.5 - 14.9 mmol/L 40.0 - 240 g/L

                                                BarP 400.0 - 800.0 minHg 53.3 - 106.7 kPa 15.7-31.5inHg

Calculated Result Resolution: HC0 - 3             0.1 mmol/L

TCO 2                   0.1 mmollL

BE-ecf            0.1 mmol/L

BE-b               0.1 mmollL

SBC                0.1 mmollL

0 2 Ct                0.1 mL/dL

P50                0.1 mmHg           0.1 kPa

      With entered Fi0 2 :               A                    0.1 mmHg           0.1 kPa

A-aD0 2           0.1 mmHg           0.1 kPa

a /A                 0.1

P0 2 /Fi0                0.1 mmHg          0.1 kPa

  With CO-OX inputs:            MetHb            0.1 %                   0.001

COHb            0.1 %                   0.001

HHb                0.1 %                   0.001

0 2 Hb               0.1 %                   0.001

0 2 Cap            0.1 mL/dL             0.01 mL/L

0 2 Ct               0.1 mL/dL                    0.01 mL/L

Combined:                                         Cc0 2        0.1 mL/dL

Ca0 2               0.1 mL /dL

Cv0 2                      0.1 mL /dL

avD0 2                  0.1 mmHg           0.1 kPa

P50                0.1 mmfig            0.1 kPa

Acceptable Samples:                        Whole Blood (heparinized)

Measuring Technology:          Ion Selective Electrodes (Na + , K + , Cl - , Ca ++ , pH, PCO 2 )

Amperometry (P0 2 , Glucose)

Conductivity (Hematocrit/Hemoglobin)

Reflectance Photornetry (Oxygen Saturation/Hernoglobin)

Analysis Rate:                                   Stet Analysis Thne                                                                                                                          Throughput Time

45 seconds                                 60 seconds

Sample Volume:                               50 microliters whole blood micro sample for blood gases

100 microliters whole blood sample size for full panel

Barometer:                            400 - 800 ±1 mmHg, accurate to 1.5 minHg

Slope Limits:                                      pH                                                   9.1 - 11.6

PCO 2                                             7.9 - 12.6

PO 2                                                -15.0 - (-1.6)

S0 2 %                                              6.9 - 18.2

Hct                                          12.0 - 50.0

Na +                                               8.8 - 11.0

                                        K +                                       8.3 - 11.1

C1 -                                               7.7 - 12.2

Ca ++                                             8.3 - 11.6

Glu                                               5.0 - 45.0

 