Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.
We would be pleased to take over the professional installation of your laboratory devices!Please contact us.
Benefit from the installation by us in more than one way:
Manufacturer warranty
Optional installation of equipment for immediate and safe use of equipment
Questions regarding this device
The manufacturer’s warranty terms apply for new devices. We will gladly inform you individually and in accordance to the chosen new device.
All used instruments of Labexchange are subject to a technical inspection before delivery and will be supplied only, when they function perfectly well. The verification and functionability is documented by a service report of an independent service company. The Labexchange Fullguarantee is 60 days from delivery date. Malfunctions occurring within the warranty period will be corrected by us free of charge. (Valid for countries within the EU and CH)
Our certificate of operativeness ensures a technically perfect condition.
You are on the safe side with our used laboratory and analysis systems! For even more security during the purchase, we are granting the Labexchange right of return.
Return your laboratory or analysis system simply without explanation.
Our special terms and conditions are to be applied:Labexchange right of return(https://www.labexchange.com/fileadmin/user_upload/pdf/downloads/en/Rueckgaberecht_08_18_E.pdf)
Play it safe! We are pleased to offer you the installation of your laboratory equipment. Our qualified technicians install the device on your desired date in the laboratory, so that you can work quickly and safely with your new laboratory equipment.
* Required Fields
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country
Possible payment methods
Comment
DE, AT, CH
Payment by invoice, payment in advance
Payment by invoice is only possible for corporate clients.
NL, BE, LU
Payment by invoice is only possible for corporate clients
Other countries
Payment in advance
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
All articles are used articles, except an article is listed especially as a new device.
Status
Condition
Immediately available
Used
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.
Published
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.
New device
new
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.
Manufacturer: Labexchange
Model: ECS11
The following illustrations and descriptions refer to the device model and come from brochures.
They are not the scope of delivery. For the exact scope of delivery please refer to the offer text.
Technical specifications
FLASH 14 DAD 400 detector
It is a UV-visible diode array detector capable of measuring the absorption of four wavelengths in the range of 200 - 400 nm simultaneously in one cell, as well as the visualization of whole spectra.
It is possible to use the detector in flash and preparative applications. By default, a PLCC 15 preparative cell is assembled, but other cells are available
ECP2100 Preparative Pump
This isocratic pump works with the ECB2007 gradient box as a quaternary gradient pump. Flow rate is 1-100 ml / min and pressure limit at 15 MPa.
The device software includes a new learning algorithm for pulsation suppression and many test and diagnostic functions
ECB2006 box for bottles
Box is suitable for handling liquids in ECOM isocratic system. It houses a stainless steel container for solvent bottles.
ECOMAC chromatography software
This system is completely controlled by the ECOMAC software, which is also part of the delivery. It allows all units to control, create gradients, and collect fractions.
Flash 14 DAD 400 detector
Wavelength range (four wavelengths at the same time) 200 - 400 nm (256 elements on CCD)
Typical spectral half width 8 nm
Adjustment accuracy ± 1 nm
Reproducibility ± 0.5 nm
Light source deuterium discharge lamp
Noise level at the test cell (254 nm, TC 0.75 s) ± 5 × 10 -5 AU
Drift in the test cell (254 nm after 1 h) 1 × 10 -3 AU / h
Materials in contact with the mobile phase PTFE; Quartz glass, stainless steel
Time constant (T90) 0.5 s; 0.75 s; 1 s or 2 s (T63 0.3 s, 0.4 s, 0.6 s, 1 s)
Output for integrator 1 V / AU (only in digital form)
Interface RS232
Power supply 90-264V
Power consumption 90 VA
Dimensions (W x H x D) 280 x 130 x 463 mm (11.02 x 5.12 x 18.23 in)
Weight 9 kg
PREPARATION CELLS PLCC 15 (EQUIPPED WITH DEVICE)
Volume / optical path (adjustable) 45 μl / 0.3 mm; 55 μl / 1.4 mm; 70 μl / 2.4 mm
Cell connection tube with OD = 1/8 ", thread 1/4" -28
Maximum flow rate 500 ml / min
ECP 2100 pump
Flow rate 0.1 - 100.0 ml / min.
Pump system two pistons dia. 3/8 "connected in parallel
Maximum operating pressure 15 MPa (2176 PSI, 150 bar)
Accuracy of flow rate (10 ml / min, 12 MPa H2O) ± 2%
Repeatability of flow rate (10 ml / min 12MPa H2O) ± 0.5%
Accuracy of pressure measurement ± 2%
Adjustable lower pressure limit 0.0 - 14.0 MPa
Adjustable upper pressure limit 1.0 - 15.0 MPa
Number of valves * 4 (A, B, C, D)
Adjustment of component concentrations * 0.0 - 100.0%
Wetted materials stainless steel, sapphire, KEL-F, gaskets **
Communication RS232, Ethernet (LAN), USB
Display, keyboard VFD 140x32 pixels, 10 buttons
Power supply 100-240V 50 / 60Hz 100VA
Dimensions (W x H x D) 280 x 135 x 498 mm (11.02 x 5.12 x 18.23 in)
Weight 12 kg (26.5 lb)
Outer diameter of the output capillary 1/16
Inner box dimension (WxHxD) 270 x 56 x 442 mm
Dimensions (WxHxD 280 x 135 x 498 mm
Weight 2kg
Your Labexchange-Team will gladly help:
Christian Schmid Laboratory and analysis, Laboratory equipment, Life science
Hubert Sauter Spectroscopy, Chromatography