Description:
MMM Drying Cabinet Venticell 55. Temperature up to 250°C. Volume inside:55 l. Dimensions inside: H/W/D: 40/40/40 cm. YoC: 2001.
Quotation
siehe Storeview
More Information
Objektnummer B00010337
ID-number 010337
Object name MMM Venticell 55
Status Stock unit

Product group: Drying- / Heating Cabinets

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       MMM

model:                   Venticell 55

annotation:           Dokumente engl.

 

 

 

 

 

 

 

 

VENTICELL

with forced air convenction

 

 

Due to a patented ventilation system the air within the VENTICELL-chamber is ventilated in a regular spiral way. This leads to a homogenous temperature profile throughout the chamber and short heating times. Operating economy is ensured by higher rate and precision of heating in laboratories. Especially suitable for very moist goods.

 

Volume:

22, 55, 111, 222, 404, 707 litres

 

Working temperature:

10 °C above ambient temperature up to 250 °C/300 °C

 

Interior:

stainless steel, mat. No. 1.4301 (AISI 304)

 

 

 

 

Technical data                                                                        Model                           55

---------------------------------------------------------------------------------------------------------------------------

Interior of stainless steel                     volume                         cca ltrs                         55

material No. 1.4301                             width                            ca mm                         400

depth                            cca mm                        390

height                           cca mm                        350

 

Trays                                                   racks                            max. No.                      4

standard equipment     pcs. included               2

distance between

guide rails                    mm                               70

storage area (w x d)    mm                               380x335

 

Maximal weight of the load *)               per tray                        max kg                         20

inside the oven            max kg                         50

 

Door                                                                                        No.                               1

 

External dimensions                            width                            cca mm                        620

(including door and handle)                 depth                            cca mm                        640

height - incl. Foots       cca mm                        680F

diameter of the           

air branch

outer/inner                  cca mm                        52/49

 

Package dimensions                           width                            cca mm                        700

(three layers carton)                            depth                            cca mm                        730

height (incl. palette)     cca mm                        880

 

Weight                                                netto                             max kg                         55

brutto                            max kg                         66

 

Working temperature                          from 10 °C                                                       250/300

(beginning of the                                  above ambient

regulation) **)                                       temp. to °C

 

Temperature accuracy                        space deviation           cca (±)% of                  1

according to DIN 12 880 T2,                                                  the reached

at working                                                                              temperature

temperature with closed                      time variation               cca ± °C                       0,4

air flap and door, > 50 °C

 

Time required to reach

250 °C with closed air

flap and voltage 230 V                                                           cca min.                       49

 

Heat emission at 250 °C                                                         cca W                           590

 

Air exchange speed at 150 °C                                               cca/hour                       45

 

Electricity                                            max. power input         cca kW                         1,3

-mains 50/60 Hz                                  stand by                       cca W                           5

current                         A                                  5,7

11,3

nominal voltage           V                                  230

                                                                                                                                  115

 

 

 

* ) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.

 

**) Standard type is up to 250 °C, optional type is up to 300 °C.

 

Note: All technical data are related to 22 °C ambient temperature and ± 10 % voltage swing (if not specified).

 

Changes in the design and make reserved.

 

 