Sold

Millipore Labscale TFF

ID-number: 009216
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Millipore Labscale TFF. System for Sample preparation from volumina of 50-1000 ml. YoC: 2002. As new.
Quotation
siehe Storeview
More Information
Objektnummer B00009216
ID-number 009216
Object name Millipore Labscale TFF
Status Stock unit

Product group: Analyzers for specific parameters

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Millipore

Modell:            Labscale TFF

Kommentar:   Dokumente engl.

Description

The Labscale TFF System is easy to use for sample preparation while also providing the necessary controls for process development and scale-up work. The system can be operated in concentration or continuous diafiltration modes. Specifically designed to operate the Pellicon XL module, the system reservoir accepts direct docking of the device, eliminating the need for tubing connections. This feature, in addition to the diaphragm pump assembly, provides the lowest working volumes, allowing typical sample concentrations of >25 x.

The Labscale TFF System has a graduated 500mL acrylic reservoir with a retentate backpressure valve, feed and retentate pressure indicators, a stirrer assembly and diaphragm pump assembly. All wetted parts meet the requirements of USP Class VI testing and CFR 21 regulations.

Additional accessories include a Multi-Manifold Kit for mounting up to three Pellicon XL devices to the 500 mL reservoir, and a 100 mL reservoir for simple low volume separations. The Multi-Manifold can be used to run up to three Pellicon XL devices with different molecular weights to determine the best membrane for a specific process. Alternative configurations allow you to use the same molecular weight cut-off devices to speed up your processing time or process higher volumes.

Physical Data

Length, cm (in)              21.6 (8.5)

Width, cm (in)                27.9 (11)

Height, cm (in)               45.7 (18)

Weight, kg (lb)               5.9 (13)

Specifications

Materials of Construction

500 mL reservoir                                                 acrylic

Reservoir cover                                                   polypropylene

Reservoir gasket                                                 EPDM

Retentate valve diaphragm                                 EPDM and polypropylene

Luer fittings                                                          316 stainless steel/polypropylene

Tubing                                                                  LFL Tygon

Diaphragm pump housing                                   glass-filled polypropylene

Diaphragm pump diaphragm                              PTFE coated

Diaphragm pump check valve                            polypropylene and Simriz

Housing/enclosure                                              polyurethane

Multi-Manifold                                                       polypropylene

Maximum Pump Outlet Pressure, bar (psig)      5.9 (85)

Feed Flowrate, L/min                                          0.01 - 0.1

Minimum Recirculation Volume, mL                   15

Operating Temperature Range, °C                     4–45

Power

XX42 LSS 12                                                       115 V, 60 Hz

XX42 LSS 12/XX42 LSS 13                                 230 V, 50 Hz