Micromeritics Gemini 2375

ID-number: 017505
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Micromeritics Analyzer Gemini 2375. For surface determination. With 3 new rehearsing glasses. Without out heating station and vacuum pump. Software Stardriver V. 1.01 for control and analyse. Necessary operating system Win95.
siehe Storeview
More Information
Objektnummer B00017505
ID-number 017505
Object name Micromeritics Gemini 2375
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Micromeritics

model :                   Gemini 2375

annotation :           Dokumente engl.

 

 

Attention: This is description for Gemini II 2370. The Models are identical.

 

 

The Gemini Analyzer is an easy to use, fully automatic, single- or multi­point surface area analyzer. Once an analysis is started, data are collected, cal­culations performed, and results displayed without further Operator intervention. The frequent calibrations associated with presently available flow­ing-gas systems are not required. The analyzer may be operated in any of live languages: English, French, German, Italian, or Spanish.

Gemini provides rapid and accurate sample analysis, including selectable cal­culation of the following sample characteristics:

n          Single-point BET surface area

n          Multi-point BET surface area

n          Multi-point Langmuir surface area

n          t-Method micropore volume and area

n          Total pure volume

As nue as 50 data points can be collected and reported in the BET, Lang­muir, or t-Method range. Additionally, Gemini can report discrete point ad­sorption isotherms consisting of up to 1,000 adsorption points.

Up to ten Run Conditions Sets (Setup Groups) can be stored, enabling you to perform custom analyses with just a few keystrokes.

Analysis results can also be edited by specifying which points are to be included in surface area or t-Method calculations. Gemini automatically recal­culates the results and generates a new report. Reports remain available for viewing or printing until anotheianalysis is started. Results can also be trans­mitted to a remote location or computer via the standard RS-232 connector.

The Gemini Analyzer, shown in the following Illustration, contains a sample station and an attached keypad and display. The analyzer is controlled by commands entered through the keypad. The operational status of the analyzer can be continually monitored an the display.

 

 

The primary function of the Gemini is to deterrnine the surface area of solid materials. lt uses a flowing-gas technique in which the analysis gas flows into a tube containing the sample and into a balance tube, at the same time. The internal volume and the temperature surrounding both tubes are main­tained at identical conditions. The only difference is the presence of the sample in the sample tube.

The sample and balance tubes are immersed in a single liquid nitrogen bath which maintains isothermal conditions for both tubes. The analysis gas is then delivered•to the sample tube by a servo valve mechanism. The delivery rate of analysis gas flow into the balance tube is controlled by another servo valve connected to a differential pressure transducer. This differential pressure transducer measures the pressure imbalance between the sample and balance tubes, which is caused by the adsorption of the analysis gas onto the sample. As the sample adsorbs analysis gas, the pressure drops in the sample tube. The servo valve continuously restores the pressure balance between two tubes by admitting more gas into the sample tube. The end result is that the Gern­ini maintains a constant pressure of analysis gas over the sample while vary­ing the rate of analysis gas delivery to exactly match the rate at which the sample can adsorb the gas.

 

APPLICABILITY

Surface Area:                       0.1 m 2 to above 300 m 2 , total;

                                            0.01 m 2 /g and higher, specific

Pore Volume:                       4 x 10 -6 cm 3 /g and higher

 

PRESSURE MEASUREMENT

Range:                                 0 to 950 mmHg

Minimum Resolvable

Relative Pressure (P/Po):    10 -4

Pressure Resolution:           0.1 mmHg

Accuracy and Linearity:       Better than ±0.5%

(Transducer manufacturer's

specification )

 

VACUUM SYSTEM

External:                               Vacuum source achieving better than 20 x 10 -3 mmHg at the instrument inlet, and having a device to reduce oil vapor backstrearning is recommended.

The system should also have an anti­suckback valve to prevent oil from being admitted into the Gemini should there be a power failure.

 

ENVIRONMENT

Temperature:                       10 to 35 °C (50 to 96 °F) operating

                                            0 to 50 °C (32 to 122 °F) non-operating

Humidity:                              20% to 80% relative, non-condensing

 

SAMPLE TUBES

Standard Tube:                    The standard tobe has a 0.95-cm (3/8-in.)

outside diameter and is 15.5 cm (6.1 in.) long with 6.5 cm 3 of volume. Sample capacity is approximately 2.0 cm 3 .

Large Tube:                          The bulb of the large tube has a 1.9-cm

(3/4-in.) outside diameter and is 3.8 cm (1-1/2 in.) long. The tube is 15.5 cm (6.1 in.) long. Tt yields a 12.0-cm 3 volume. Sample capacity is approximately 6.0 cm 3 .

 

ELECTRJCAL

Voltage:                                85 to 264 VAC

Frequency:                           47 to 440 Hz

Power:                                  75 VA maximum

 

GASES

Adsorbate

Optimized for nitrogen in a liquid nitrogen sample bath. Gemini may be used with non­ . corrosive adsorbate gases having vapor pressures at both room and bath temperatures that are acceptably high relative to the resblution of the 1,000 mmHg pressure transducer. Typically, oxygen, argon, carbon dioxide, butane, methane, and other light hydrocarbons will produce useful data above absolute

pressures of a few mmHg.

 

PHYSICAL

Height:                                52.4 cm (20.6 in.)

Width:                                 43.8 cm (17.3 in.)

Depth:                                30.5 cm (12.0 in.)

Weight:                               22 kg (48.4 lbs)

Product group: Analyzers for specific parameters