Micromeritics FlowSorb II2300
Objektnummer | B00014687 |
---|---|
ID-number | 014687 |
Object name | Micromeritics FlowSorb II2300 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Micrometrics
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Description
The FlowSorb II2300 provides singlepoint, multi-point, full adsorption and desorption isotherms and pore volume capabilities with Speed, accuracy and rehability. Samples from 0.01 M 2 /g to over 1,000 M 2 /grn for surface area analysis and 0.005 cc to 0.3 cc total pore volume are easily accommodated. Its reproducibility is better than 0.5%.
The advanced electronics are the most modern analog and digital circuitry available and have been Chosen for reliabifity, low noise and precision. The thermal conductivity detector is temperature-regulated to reduce temperature-induced drift and therefore, erroneous results.
Initial instrument warm-up takes approximately 10 to 20 minutes. Single injection calibration provides fast startup and high sample throughput.
Specially designed sample holders can be attached and removed from the instrument with one hand. These quick connect/disconnects have a built-in shut-off valve to prevent sample contamination.
Dewar support latch System provides one-hand convenience and safety from dangerous liquid nitrogen spills.
Simple in design, the FlowSorb 11 2300 requires minimal training time and leaves little Chance for operator error. With no parts which move dunng analysis, repair time is practically eliminated.
Automatic mode switching for adsorption and desorption is accomplished without further operator attention by Dewar support placement.
The low purchase price and supplies makes this instrument the lowest cost way of measuring surface area or pore volume an a per-sample-run basis.
Features
Full adsorption and desorption isotherms.
Ultra-stable detector eliminates drift and need for constant readjustment.
Cold trag in front vs. side placement, as in other Instruments, avoids breakage.
Single injection calibration requires only one control setting. Adaptable to any non-corrosive adsorbate mix.
All controls and displays are at eye/ arm level, out of spül zone.
Built-in sample preparation.
Rugged construction for day-in, dayout Operation.
Accessories
Separate preparation device (DeSorb 2300A) for high throughput.
5 different types of sample tubes including monolith type for large Samples.
Flow Controller for operator adjustable gas mixtures.
Data reduction Software for Computer aided calculation of:
Surface area (multi-point)
Slope
Intercept
Hegt of adsorption
Total adsorbed volume by B.E.T. and / or Langmuir, T-plots.
SPECIFICATIONS:
SAMPLE PARAMETERS
Minimum Surface
Area: 0.1 M 2
Maximum Surface
Area: 280 M 2
Minimum Specific
Surface Area: Approx. 0.01 m 2 /g
Maximum Specific
Surface Area:
Limited only by weighing accuracy of
smallest sample
Minimum Total Pore
Volume: 0.005 cm 3
Maximum Total Pore Limited only be weighing accuracy of Volume:
smallest sample
Sample Holder
Volume: 4.8 cm 3 ; other sizes available
Throughput:
Single-Point: Typically 5/h
Multi - Point: Typically 1/2h
Total Pore Volume: Typically 2/hr
Outgassing
Temperature: 35-400°C
EXPOSED MATERIALS
Sample Holder: Borosilicate glass, usable to 400° C
Internal Components: Type 316 stainless steel, chrome plated brass, copper, Buna-N
CABINET
Dimensions: 46.5W x 53H x 30.5D cm
(18.3W x 20.9H x 12D in.)
Color: Beige with brown panel and rust highlights
Weight: 19 kg (42 lbs)
UTILITIES/ SUPPLIES
Accommodates to standard power mains worldwide.
Voltage: 100, 120, 220 or 240 VAC ±10%
Current: 1.4 A (100/120 VAC);
0.8 A (220/240 VAC)
Frequency: 50/60 Hz
Gas: Mixtures, with helium, of nitrogen, argon, krypton, carbon dioxide, ethane, n-butane, and other noncorrosive gases. A mixture of 30% N2 and 70% He is recommended for single point analyses. Mixtures of He and approximately 5,12,18, and 247. N2 are suggested for multipoint use.
A mixture of 95% N2 and 5% He is recommended for total pore volume measurements.
Coolant: Liquid nitrogen or Oxygen, solvent slush baths, ice water as appropriate for adsorbate.
ACCURACY/ REPRODUCIBILITY
Low Specific Surfaces:Typically better than ±3%. (single point method) and ±2% (multipoint method) with reproducibility within ±0.5%
Moderate and High Typically better than ±2% (single
Specific Surfaces: point method) and ±1.5% (multipoint method) with reproducibility within ± 0.5%
Total Pore Volume: Typically better than ± 3%
ENVIRONMENT
Temperature: 15-30 °C (59-90 °F) operating; 0-5 0°C (32-122 °F) storing and
shipping
Humidity: 20-80% relative (non-condensing)
DeSorb 2300A
KEY FEATURES
Dramatically increases sample throughput
Samples remain pure during transfer
Economical, yet rugged in construction
Throughput Increases Dramatically
The DeSorb 2300A is a threestation outgassing unit designed to significantly increase the number of samples that can be analyzed by the FlowSorb 2300 particle analyzer. In fact, the DeSorb 2300A increases the sample throughput of the FlowSorb by as muck as 300 percent. Whether a sample requires twenty minutes to Begas or four hours, the three outgas‑
ing ports on the DeSorb 2300A maximizes sample throughput thereby reducing backlog.
Most samples completely de-gas in 15 to 20 minutes at 200 to 250°C. This means the DeSorb-FlowSorb pair Gould process between 70 and 80 samples per day analyzing single-point surface areas of 25 m2/g or less. Even if you are performing multipoint analysis on surface areas of 500 m2/g, and outgassing for four hours, you can increase throughput to eight samples per day with the DeSorb-FlowSorb pair.
A Simplified Outgassing Process
Operation of the DeSorb 23OOA is quite simple and very reliable. The sample is heated to drive off moisture and other impurities from its surface while a constantly flowing inert gas sweeps away the liberated impurities.
Heating the sample is easy. Heating mantles, construced with nickel wiring for depend-
ability, are slipped around the sample tubes. The Operator simply preselects the tempera‑
ture with a digital thumbpot. The temperature is maintained by a time sharing proportional control circuit, accurate to within ± 5°C from 35 to 250°C and within ± 10°C from 250 to 400°C. Maximum temperature of outgassing is 400°C.
The inert gas used to clean the sample : must have a dew point of at least 67°C to minimize the introduction of moisture. The most widely used gasses are nitrogen and helium. Located above each sample tube Station are LED displays indicating when the inert gas is flowing at the appropriate rate, normally 15 to 20 cm 3 per minute.
Unique Design Prevents Contamination
Transferring the degassed samples to the FlowSorb for analysis takes a matter of seconds. The sample tube is attached or removed from the Instrument with one hand. Specially designed sample tube connectors engage built-in shut-off valves to prevent sample contamination during transfer. Up to three samples can be concurrently degassed, and any one can be removed and replaced at any time without disturbing the others.
Quality Engineering
State-of-the-art electronic and mechanical components are used in the design and construction of the DeSorb 2300A. It has been engineered to endure mang years of heavy use. Sintered stainless steel restrictors control the gas flow. Sophisticated digital circuitry ensures the highest accuracy.
The DeSorb 2300A is designed to include all the features you need at a price to fit youbudget. Whether you are performing researc.- or quality control, the DeSorb 2300A is costefficient without compromise.
SPECIFICATIONS
Dimensions:
46.5W x 53H x 30.5D cm
(18.3W x 20.9H x 12D in)
Weight:
15.4kg (34 lbs.)
Electrical:
Uses Standard power mains worldwide; 100, 120, 220, or 240 VAC ± 10%; 50/60 Hz; 1.3.P., (100/120 VAC); 0.7A (220/240 VAC).
Purge Gas:
Nitrogen, helium, or nitrogen-helium mixture: Research-grade recommended. If these are not available, a gas having a dew point of at least -67°C (-88°F) should be used.
AutoMate 23
Automatic Operation
Provides automatic control of adsorption and desorption operations by raising and lowering the liquid nitrogen Dewar and causing the display to read total surface area when the analysis is completed. This increases efficiency and throughput while decreasing the amount of operator Intervention.
Rapid and Efficient Analysis
Provides continuous operation without Interruption of analysis due to operator involvement in other activities.
Consistent Results
Provides accurate and repeatable results, as analyses are performed automatically and in the saure manner.
Convenient Status Indicators
Provides reduction in the amount of time between analysis, as both audible and visible signals indicate when an analysis is complete.
One-Step Analysis Interrupt
Provides quick and easy discontinuation of an analysis at any point during the analysis process and automatically resets for a subsequent analysis. This results in improved efficiency.
Easy Installation
Permits quick and easy setup for automatic analyses or removal for manual analyses.
DESCRIPTION
The AutoMate 23, Micromeritics" new attachment for the FlowSorb II 2300 Surface Area Analyzer, automates the analysis process. The AutoMate consists basically of an automatically-operated Dewar elevator, an automatic fan with Output directed toward the sample tube, and specially designed electronics which detect and regulate analysis operations. It is designed such that it mounts easily onto the Micromeritics FlowSorb II2300.
The AutoMate eliminates the need for the operator to perform several manual operations: applying a Dewar of liquid nitrogen to the sample to induce adsorption; removing the Dewar following adsorption; and warming the sample to induce desorption. During the analysis, the AutoMate raises the Dewar of liquid nitrogen about the sample being analyzed. This results in nitrogen being adsorbed. This nitrogen adsorption is automatically detected and monitored by the AutoMate until adsorption is complete. At this point, the AutoMate automatically lowers the Dewar, and directs a vigorous stream of air toward the sample tube. This results in desorption. The AutoMate then monitors the desorption process and indicates when desorption is complete. The operator simply records the result displayed an the FlowSorb II.
Surface area analysis with the AutoMate installed only requires the operator to prepare the sample for analysis_ properly, to activate the AutoMate, and to record the analysis result when the AutoMate indicates (with both audib- II, and visible indicators) that analysis is complete. Once analysis is complete, the operator can either install a new sample for analysis, repeat the analysis of the saure sample, or continue the analysis using a different gas composition. Neither operator Intervention nor Observation is required during analysis.
Specification
Operating Modes: Short Path and Long Path. As a qualitative guide for sample analysis with the FlowSorb II2300, use the smallest appropriate quantity of sample. A sample with a total surface area of less than 10m 2 should be analyzed in the skort path mode and a sample with a greater total surface area should be analyzed in the long path mode.
Sample: Any sample that can be analyzed with the FlowSorb II2300 using standard sample tubes and the standard procedure, i.e., warming by water immersion, can be analyzed with the AutoMate 23.
Voltage: 100, 120, 220 or 240 VAC ± 10%
Current: 0.5A (100/120 VAC); 0.25A (220/240 VAC)
Frequency: 50/60 Hz
Temperaturei 15-32 °C (59-90 °F) operating; 0-50 °C (32-122 °F) storing and shipping.
1-lumidity-. 20-80% relative (non-condensing)
Dimensions: 11.5W x 22.2H x 26L cm (4.5W x 8.75H x 10.24L in.)
Weight: 4.1 kg (9 lbs)