Mettler DL 58

ID-number: 017054
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Mettler Toledo Titrator DL 58. 220 V. 50 Hz. 400 mA. CE-marked. 2 burettes á 10 mL. Stirrer DL5x. Phototrode DP550. Temperation sensor. Operating field. Digital display. All connection and interconnecting cables
siehe Storeview
More Information
Objektnummer B00017054
ID-number 017054
Object name Mettler DL 58
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Mettler

Modell:                DL 58

Kommentar:        Dokumente deut.

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

 

 

Leistungsstark und aufrüstbar:
Der DL58 ist mit allen Leistungsmerkmalen des DL55 ausgestattet und verfügt darüber hinaus über das flexible METTLER TOLEDO-Methodenkonzept, mit dem praktisch jede Methode entwickelt werden kann. Damit ist der DL58 der Spezialist auf dem Gebiet der Methodenentwicklung. Die mit dem DL58 entwickelten Methoden können auch auf dem DL53 oder dem DL55 mit optionalem Erweiterungsdongle verwendet werden.

 

Technische Daten Messsystem

Endpunktindikation

•    potentiometrisch

•    photometrisch

•    Änderung von Brechzahl und/oder Trübung

•    voltametrisch/amperometrisch

•    konduktometrisch                                    Fremdgerät mit Analogausgang

 

Temperaturkompensation                        Temperatureingabe über Tastatur oder auto‑

für pH/pM/pX-Messung                                matisch mit Hilfe eines Temperatursensors

 

Sensoreingang: pH-Steckkarte

(Differenzverstärker)                                    Triaxial-Buchse (LEMO)

•    Eingangswiderstand                                >10 12   (geschützt bis 1000 V kapazitiv)

•    Offsetstrom                                              <1 pA (20 °C)

•    Messbereich

    - pH-Wert                                                 27,6 pH

    - Spannung                                              2050,0 mV

•    Auflösung                                                 0,1 mV, 0,002 pH (pM, pX)

•    Fehlergrenze für Messabweichung         0,1%

•    Nullpunktdrift                                            <30 V/ °C

•    Zusatz-Referenzelektrodeneingang        Bananenbuchse, Durchmesser: 4 mm

 

Temperatursensoreingang                      4 polige Buchse (LEMO)

•    Messbereich                                            -30 °C bis 130 °C

•    Auflösung                                                 0,1 °C

•    Fehlergrenze für Messabweichung         0,1 °C

•    Messprinzip                                              4-Leitermesstechnik: Pt100 (Standard) od. Pt1000

•    Nullpunktdrift                                            <0 ,01 °C/ °C

 

Sensoreingang: KF-Steckkarte

Sensoreingang                                             2 Bananenbuchsen, Durchmesser: 4 mm

 

Spannungsquelle

•    Bereich                                                     -1270 bis +1270 mV

•    Auflösung                                                 10 mV im Bereich von -1270 bis +1270 mV

                                                                    1 mV im Bereich von -127 bis +127 mV

•    Messbereich                                            -150 bis +150 µA

•    Auflösung                                                 0,01 µA (16 Bit AD-Wandler)

•    Fehlergrenze für Messabweichung         0,1%

 

Stromquelle

•    Bereich                                                     -127 bis +127 µA

•    Auflösung                                                 1 µA im Bereich von -127 bis +127 µA

                                                                    0,1 µA im Bereich von -12,7 bis +12,7 µA

•    Messbereich                                            -1500 bis +1500 mV

•    Auflösung                                                 0,1 mV (16 Bit AD-Wandler)

•    Fehlergrenze für Messabweichung         0,1%

 

Ausgänge

Rührerausgang                                          5 polige Buchse (Mini DIN)

•    Spannungsbereich                                   0 – 18 V im Leerlauf

•    Drehzahlstabilisiert                                  Typisch: <5%

der Ausgang ist elektronisch gegen Überla­stung geschützt, Imax: 300 mA

   

Analogausgang                                          2 Bananenbuchsen, Durchmesser: 2 mm

•    Verstärkung                                              1

•    Offset: Fehlergrenze                                35 mV

•    Bereich                                                     ±2000 mV

•    Bereich: Fehlergrenze                             1%

•    Ausgangswiderstand                               220 Ω

 

Bürettenantriebsmodul

Mit Gleichstrommotor

Bestückung                                                  DL50/DL53: max. 1, DL55/DL58: max. 2

Auflösung                                                     1/ 5000 des Bürettenvolumens

Fehlergrenze für Messabweichung             0,3% bezogen auf das jeweillige Bürettenvolu‑

                                                                    men von 5, 10 und 20 mL

Füllzeit                                                          20 s

Ausstosszeit                                                Minimal 20 s

 

Wechselbüretten

Volumen                                                       1, 5, 10 und 20 mL

Materialien, die mit Titriermittel

in Berührung kommen                                 Fluorkunststoff, Borsilikatglas, Keramik

 

Stabrührer

Maximale Drehzahl                                      3800 U/min

Leistungsaufnahme                                     P max .:      6 W

                                                                    P typisch :    1,2 W bei 12 V

 

Anzeige

Graphikfähige Flüssigkristallanzeige           6 Zeilen, 39 Zeichen pro Zeile

240 x 64 Bildpunkte, Hinterleuchtung durch Kaltkathoden-Fluoreszenslampe

Sprachen                                                     Deutsch, Englisch, Französisch,

                                                                    Spanisch und Italienisch

 

Speicher

Datenbank                                                    METTLER-Methoden, Standardmethoden

Benutzerdatenspeicher (EEPROM)            Benutzermethoden, Hilfsmittel- und Proben‑

daten, Speicherplatz für ca. 50 Standard-Methoden

 

Schnittstelle für Speicherkarte

Steckplatz für 68 polige Speicherkarte

vom Typ 1                                                    Standards, die unterstützt werden:

                                                                    • PCMCIA, Version 2.0

                                                                    • JEIDA, Version 4.1

Speicherkarten, die eingesetzt werden

können:

1. Flash Memory Card Serie 2

von Intel mit der Bezeichnung:                    • iMC002FLSA - 20 (2 MB Speicherkapazität)

                                                                    • iMC004FLSA - 20 (4 MB Speicherkapazität)

von Mitsubishi mit der Bezeichnung:          • MF82M1-G7DAT 01 (2 MB Speicherkapazität)

                                                                    • MF84M1-G7DAT 01 (4 MB Speicherkapazität)

2. SRAM Melcard von Mitsubishi

mit der Bezeichnung:                                   • MF31 M1-LCDAT 01 (1 MB Speicherkapazität)

 

Anschlussmöglichkeiten für Peripheriegeräte

Waage                                                         Anschluss über RS232C-Schnittstelle der Centronics- oder einer RS-Steckkarte auf Platz Nr. 4 für METTLER TOLEDO und SARTORIUS Waa­gen

Drucker                                                        Anschluss überdie Centronics-Schnittstelle der Centronics-Steckkarte oder über die RS232C­Schnittstelle einer RS-Steckkarte auf Platz Nr. 4 für verschiedene handelsübliche graphikfähi­ge Drucker (bei Verwendung der RS-Steckkar­te mit XON / XOFF-Protokoll)

Probenwechsler ST20A                               Anschluss über RS232C-Schnittstelle der RS‑Steckkarte auf Platz Nr. 3 (als Option erhältlich)

Terminal oder Computer                             Anschluss über RS232C-Schnittstelle der RS‑

(LIMS: laborinternes Informations-               Steckkarte auf Platz Nr. 3 (als Option erhältlich)

und Management-System)

Hilfsgeräte (Fremdgeräte)                           Anschluss über TTLIO-Buchse der RS-Steckkarte auf Platz Nr. 3 (als Option erhältlich)

Externe Tastatur (Fremdgerät,                    Anschluss über die DIN-Buchse, 5 polig z.B. handelsübliche PC-Tastatur)

Product group: Titrators