Mettler Karl Fischer Coulometer DL 37. Integrated printer.
siehe Storeview
More Information
Objektnummer B00014818
ID-number 014818
Object name Mettler DL 37
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                Mettler

Modell:              DL 37

Kommentar:      Dokumente deut.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.


Mit dem DL37 lassen sich Spuren von Wasser mit sehr hoher Genauigkeit bestimmen.

Das DL37:

•     ist für fünf Methoden programmiert, die in dieser Bedienungsanleitung beschrieben wer­den (vgl. Kap. 4).

•     bietet die Möglichkeit, die Titrationsparameter (Regelverstärkung, Anzeige des Endpunk­tes, usw.) entsprechend der Titrationsaufgabe zu wählen und so eine optimale Messme­thode mit kurzer Titrationszeit und hoher Genauigkeit zu erreichen.

•     kann automatisch oder manuell gestartet werden. Nach Zugabe der Probe beginnt die Titration automatisch, sobald das DL37 das zugesetzte Wasser erkennt.

•     erlaubt die Eingabe des Probengewichts vor, während oder nach der Titration von Hand oder automatisch über die angeschlossene Waage.

•     bildet in Verbindung mit dem METTLER D0337 Trockenofen ein weitgehend automati­siertes System. Damit lässt sich Wasser in Feststoffen auf sehr einfache Weise bestim­men.

•     besitzt eine automatische Drift-Bestimmung, die in der Resultatberechnung berücksichtigt wird.

•     verfügt über eine Einrichtung zur statistischen Auswertung (Mittelwert, Standardabwei­chung und relative Standardabweichung) und ermöglicht eine Nachberechnung von Re­sultaten.

Auf dem Drucker werden die Titrationskurve und eine Liste der Titrationsdaten ausgedruckt. Ausserdem kann eine Liste der Titrationsdaten (Zeit, Wassergehalt pro Zeitintervall, auf­summierter Wassergehalt) ausgedruckt werden.

Technische Daten

Bezeichnung und

Betriebsart                            METTLER KF-Coulometer DL37

Messmethode                       Coulometrische Titration nach Karl Fischer

Steuersystem                       Zeitsteuerung mit Konstantstromimpulsen durch Mikroprozessor

Endpunktdetektion                durch Wechselstrompolarisation

Zustandsanzeige für             zu hohe Feuchtigkeit (Pretitr) Pretitr:    zu hoher Wassergehalt in

eine Titration                                                                                       der Titrationszelle

                                             Titration möglich (Ready)       Ready     :Titration möglich

                                                           Drift stabil (Stable)                  Stable:                                                            Titration möglich (Drift sehr stabil)

Endpunktanzeige                  akustisches Signal

Rührmethode                        Magnetrührer. Drehzahl durch Tasteneingabe in Stufen einstellbar.

Titrationszelle                        Kapazität 100 mL (maximal 150 mL)

Messbereich                         10µg - 100 mg H 2 0-Gehalt der Probe

Nachweisempfindlichkeit      0,1 µg H 2 0

Reproduzierbarkeit               Die relative Standardabweichung der Titration von 1 mg H 2 0 in Methanol liegt unter 0,3 %.

Drift                                       Automatische Kompensation. Funktion der automatischen   Kompensation wählbar. Die Drift wird ständig angezeigt.

Anzeige der

Wassermenge                     Von 0,1 µg bis 999,9 µg und von 10000 µg bis 99999 µg. Die

Eingabe für die Titrati-          Konzentration wird nach der Titration angezeigt.

Onszeit

Start der Titration                  Startverzögerung der Titration: max. 9999 Sekunden

                                             Zeitgrenze für die Titration: max. 9999 Sekunden

Speicherfunktion                   wählbar: automatischer oder manueller Start

Berechnungsfunktion            Unabhängiger Speicher für die Titrationsbedingungen und die Berechnungsformeln. Betriebsarten (fünf Betriebsarten) nur für den Benutzer.

                                             Berechnung von Konzentrationen und von statistischen Daten.

                                             • Wassergehalt (gg oder mg H20) (gg, mg, ppm oder %)

                                             • Konzentrationsberechnung zur Bestimmung des Wassers in ein­gewogenen flüssigen oder festen Proben

                                             • Konzentrationsberechnung zur Bestimmung des Wassers in
Lösungsmittelextrakten aus flüssigen oder festen Proben

                                             • Berechnung zur Bestimmung der flüssigen Proben mit bekanntem Volumen

                                             • Berechnung zur Bestimmung des Wassers in gasförmigen Proben mit bekanntem Volumen

                                             • Konzentrationsberechnung zur Bestimmung des Wassers in Lösungsmittelextrakten aus festen Proben

                                             Funktion für Nachberechnungen

                                             • Statistikberechnungen und andere Daten können frei gelöscht werden

Anzeige des Betriebs-          Angezeigt werden

zustandes                             • die Drift

                                             • die Polarisationsspannung

                                             • die Kapazität des Anolyten

                                             • die Kapazität des Katholyten und

                                             • der Spülzustand (bei Anschluss eines METTLER Trockenofens D0337)

Ausdruck                               20 Zeichen pro Zeile. Thermopapier in Rollen von 60 mm Breite. Die Titrationskurve wird grafisch ausgedruckt.

                                             Resultate:

Datum, Probennummer, Losnummer, Berechnungsformel, verwendete Probenmenge, Wassermenge, berechneter Wassergehalt (gg, mg, ppm oder %), Titrationsdauer, Endpunkt, Drift, Kapazität der Reagenzien.

                                             Statistische Berechnungen:

Anzahl der Proben (N), Mittelwert (MEANS), Standardabweichung (SD) und relative Standardabweichung (CV).

                                             Datenliste:

                                             Wassergehalt und Titrationskurve im zeitlichen Verlauf.

Ansteuerung des Trok-         • Titrationsablauf für die verdampfte Feuchtigkeit bei

Kenofens                                 angeschlossenem METTLER Trockenofen D0337 einstellbar.

                                             • Heiztemperatur und Titrationsablauf für den METTLER Trockenofen D0337 im Speicher des DL37 speicherbar.

Selbstüberwachung              Selbstdiagnose durch Fehlermeldungen (Drucker und Anzeige), Fehlermel­dungen nach Tasteneingaben, Papiermangel im Schreiber, falsche Elektro­lysestromstärke, falsche Resultate, Übertitration, Kapazität des Anolyten, Kapazität des Katholyten, falsch eingestellte Parameter, Elektrodenkurz­schluss, Elektrodenunterbrechung.

Schnittstellen (Option)         Elektronische Waage anschliessbar, die das Probengewicht automatisch übermittelt. Über RS-232C-Schnittstelle an einen externen Computer an-schliessbar für externe Steuerungen, z.B. für das Einlesen von Daten, Start oder Stoppen der Titration oder für Rechen- und Steueraufgaben, z.B. das Auslesen von Datenlisten.

Stromversorgung                  100/120/220/230/240 VAC ±10%

                                             50/60 Hz

                                             80 VA

Aussenabmessungen           360(B) x 420(T) x 235(H) mm

Sicherungen                          T1,61-250V; T3,151-250V

Gewicht                                 etwa 11 kg

Umgebungsbedingun-          • Verwendung nur in Innenräumen

gen                                        • Höhe bis 2000 m

                                             • Umgebungstemperatur: +5 bis +35 °C

                                             • maximale relative Luftfeuchte 80% für Temperaturen bis 31 °C, linear abnehmend bis zu 50% relativer Feuchte bei 40 °C

                                             • Überspannungskategorie: II

                                             • Verschmutzungsgrad: 2