Archive

Metrohm 726

ID-number: 018445
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Metrohm Titroprocessor 726. With Ti-stand 727. 3x Dosino 700 with 10,20 and 50 mL. For Karl-Fischer. 2x Data card. Integrated printer. Display. Operating field. Option: Electrodes on inquiry for an extra charge available. YoC 2002
siehe Storeview
More Information
Objektnummer B00018445
ID-number 018445
Object name Metrohm 726
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Metrohm

Modell:                726

Kommentar:        Dokumente deut.

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

 

Technische Daten

 

Der Titroprocessor 726 ist ein kompaktes Titrier- und Messgerät für die Anaiytik in Labor und Betrieb. Anschlussmöglichkeiten für 1 oder 2 Probenwechsler, 4 potentiometrische Sensoren ( pH / mV), 2 polarisierbare Elektroden, 2 Temperatursensoren usw.

 

32-Bit Mikroprocessor , 16 MHz Taktfrequenz, 2 MByte batteriegestütztes SRAM, 2 MByte EPROM.

 

Echtes Multitasking mit dynamischer Speicherverwaltung.

 

Abmessungen          

Höhe:               25 mm (mit eingebautem Drucker)

175 mm

Breite:              405 mm

Tiefe:                500 mm

 

Gewicht          

12,6 kg (mit eingebautem Drucker)

11,1 kg (ohne Drucker)

 

Material         

Gehäuse:                     PUR (Polyurethan)-Hartschaum mit Flammschutz für Brandklasse UL94VO, FCKW-frei

Netzversorgung      

Netzspannung:            100...120 V ± 10 %, 220...240 V ± 10 %

Netzfrequenz:             50...60 Hz

Energieverbrauch:       max. 160 VA

Sicherung:                   2 ATH (träge, mit grossem Schaltvermögen)

5 mm Ø, 20 rnm lang

 

Bildschirm     

Typ:                              LCD-Bildschirm, hinterleuchtet

Bildschirmdiagonale: 257 mm

Auflösung:                    640 x 400 Punkte, 4 Graustufen;

28 Zeilen zu je 80 Zeichen

Wiederholfrequenz:     72 Hz

Kontrast:                      einstellbar

 

Tastatur         

Schaltpillentastatur mit Druckpunkt, spritzwasserdicht

 

Kommunikationsschnittstellen      

2 x RS232 für serielle Datenkommunikation mit Waage, PC oder Drucker

Norm:                           EIA RS232C, CCITT V.24, ISO 2110, DIN 66020

Buchse:                       D-Sub 25-polig

max. Baudrate:            9600

 

Remote-Schnittstelle für die Steuerung externer Geräte

Typ:                              Logik Steuerleitungen

Leitungen:                    8 Output, Opencollector , V CE = 40 V, I C = 20 mA

8 Input, Pullup auf 5 V

1 Speisung, 4...5.5 V, 200 mA

1 GND

 

 

 

Drucker (Variante)   

Typ:                              Thermodrucker

Papier:                                     Endlos-Thermopapier A4, perforiert

Auflösung:                    84 dpi im Textmodus

160 dpi im Grafikmodus

Anschlüsse                  • Barcode-Leser-Anschluss für Dateneingabe

Buchse:                       D-Sub Buchse, 9-polig nach RS232C

Übertragungs-                        

einstellungen :             Baudrate          9600

Datenbit           8

Stoppbit           1

Handshake     RTS/CTS

Zeilenende:                  CR/LF

Eingangspuffer:           40 Zeichen

Zeichensatz:                7-Bit ASCII

Pinzuordnung:             Pin 1     ernpty               Pin 6     empty

Pin 2    TxD (Output)   Pin 7     RTS (Output)

Pin 3    RxD (Input)      Pin 8     CTS (Input)

Pin 4    empty               Pin 9     +5 V

Pin 5    GND (0 V)

Verdrahtung:                726-Buchse                 Barcode-Leser

TxD                          RxD

RxD                         TxD

RTS                         CTS

CTS                         RTS

GND                         GND

+5 V                         +5 V

 

• 4 x Metrohm Dosimat 685 oder Dosino 700

Buchse:                       D-Sub Buchse, 9-polig

 

• 1 oder 2 Rühreranschlüsse für Metrohm Rührer 728 oder ähnlich Ausgangsspannung: 10,8...13,2 V

Strom: 2                       50 mA

kurzschlusssicher und schaltbar

 

• Metrohm External Bus Anschluss für:

• 2 x Probenwechsler 717

• 2 x Dosimat-Interface 729 für je 4 x Dosino 700 oder

   Dosimaten 685

 

• Druckeranschluss (Variante), Parallelport für Standarddrucker Buchse: D-Sub Buchse, 25-polig

 

Messteil         

1 oder 2 (Variante) Messgruppen mit je

• 2 hochohmige Messeingänge für pH- , Redox- , ISE-Sensoren

• 1 Referenzeingang für separate Referenzelektrode

    (obige Anordnung kann als Differenzverstärker eingesetzt werden)

• 1 Messeingang für polarisierte Elektroden

• 1 Messeingang für Temperatursensoren Pt 1000 oder Pt 100, mit automatischer Erkennung

• 1 Polarizer

• 2 parallele A/D-Wandler, 20 Bit, 50 ms Messrate

• 1 Rühreranschluss (siehe oben)

 

Galvanische Trennung

Alle Signale eines Interface sind auf ein gemeinsames Referenzpotential bezogen. Der Referenzpunkt ist gegenüber der restlichen Schaltung galvanisch getrennt. Jedes Interface ist einzeln getrennt.

Die rein messtechnisch bedingte Trennung erfüllt nicht die Anforderungen einer Sicherheitstrennung,

 

Messbereiche          

potentiometrisch:        -2500 mV...2500 mV

pH-20,000...20,000

amperometrisch         -250µA...250µA ( Upol )

voltametrisch               -2500 rnV ...2500 mV ( Ipol )

Temperatur:                -150 °C...450 °C

 

Messfehlergrenzen

Eingänge                                 abs. Fehler                  Auflösung

Ind A1, A2, B1, B2                   < ± 0 ,8 mV                   5 µV

Diff A, Diff B                             < ± 4 ,0 mV                    5 µV

Pol (µA, Upol )                         < ± 3 µA                        0,001µA

Pol (mV, Ipol )                           < ± 20 mV                     5µV

Pt100/1000

0°C…100°C                < ± 0,3°C                     0,005°C

 

Referenzbedingungen

Die Messfehlergrenzen gelten ab Werk bei einer Umgebungstemperatur von 25°C (±- 5°C) und nach 5 Min. Einschaltdauer.

Die Messfehlergrenzen der Temperaturmessung gelten inklusive der Überbergangswiederstände der Buchse und inklusive einem Sensorkabel des Metrohm Pt100 Temperaturfühler NS, aber exklusive die Fehlergrenzen des Sensors selbst.

 

Quellengenauigkeit Polarizer

Polarisationsspannung ( Upol )

Messbereich:                          -1270 mV...1270 mV

Linearität:                                 < ± 20,0 mV

Auflösung:                                10,0 mV

 

Polarisationsstrom ( Ipol )

Messbereich:                          -127 µA...127 µA

Linearität:                                 < ± 3,0 µA

Auflösung:                                1,0 µA

 

Umgebungs-Temperatur    

Nomineller Funktionsbereich             5…40 °C

Lagerung, Transport                           -25...60 °C

 

Umgebungs- Luttfeuchtigkeit

bei < 40 °C                               max. 95% relative Luftfeuchtigkeit

bei 45°C                                   max. 70% relative Luftfeuchtigkeit

bei 60°C                                  max. 35% relative Luftfeuchtigkeit

 

Titrier- und Messmodi

DET                 dynamische Endpunktitration ; U, pH , I pol , U pol

MET                 monotone Endpunkttitration ; U, pH , I pol , U pol

SET                  Titration auf vorgegebenen Endpunkt; U, pH , I pol , U pol

SEC                 Konditionieren auf vorgegebenen Endpunkt; U, pH , I pol , U pol

KFT                  Karl-Fischer-Endpunkttitration ; I pol , U pol

KFC                 Konditionierung nach Karl Fischer; I pol , U pol

MEAS              Messung ; U, pH, I pol , U pol   T

CAL                  pH-Kalibrierung

 

Speicher

Programmspeicher:                EPROM, max. 4 MB

Datenspeicher:                        2 MByte SRAM, batteriegestützt

Bestimmungsspeicher:         für bis zu 20 Bestimmungsdatensätze,

mit jeweils bis zu 5 Titrationen oder Messungen

Methodenspeicher:                  für frei definierbaren Ablauf, bis zu 99 Befehlszeilen

Silospeicher:                            Probendatenspeicher für bis zu 160 Probendatensätze

Dateispeicher:                                    freier RAM-Bereich zur Ablage von Bestimmungen, Methoden,

Probensilos

 

Datenkarte

Typ:                                         Momory Card nach Standard JEIDA 4.X / PCMCIA

2.X (68 Pins)

Speicherkapazität                   je nach Modell, 128 KByte; andere

Versionen bis 2 MByte

Sicherheits- Spezifikation

Konstruktion und Prüfung gemäss IEC 1010 / EN 61010 / UL 3101-1,

Schutzklasse I

Schutzgrad IP 52

 

Die Gebrauchsanweisung enthält Informationen und Warnungen, die vom Benutzer befolgt werden müssen, um den sicheren Betrieb des Gerätes zu gewährleisten.

 

Elektromagnetische Verträglichkeit (EMV)

Störaussendung:                     Das vorliegende Gerät erfüllt die Fachgrundnormen EN 50081-1 01.92, EN 55011 (Klasse B), EN 55022 (Klasse B), und NAMUR.

 

Störfestigkeit:                          Die Normen Erfüllt EN 50082-2; 1995, IEC801-2 bis IEC801-6, EN 60555-2 und NAMUR werden eingehalten.

 

 

Product group: Titrators

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure