Metrohm 716 DMS

ID-number: 013067
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Metrohm Titrino DMS 716. YoC: 2001
siehe Storeview
More Information
Objektnummer B00013067
ID-number 013067
Object name Metrohm 716 DMS
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Company:    Metrohm

Model:          DMS 716

 

 

The following illustrations and descriptions are model-based and drawn from brochures.

Do not give the delivery volume again.

The exact delivery content you will find only in the offering text.

 

 

 

Technical Specifications

 

 

 

Modes

 

DET: Dynamic Equivalence titration

MET: Monotonic Equivalence titration

SET: Titration to preset endpoint (Set Endpoint Titration)

MEAS: Measurement

CAL: pH calibration

 

 

 

Measurement inputs

 

2 high-impedance measuring inputs for pH, redox, ISE electrodes

1 reference input for a separate reference electrode.

The arrangement can also be used as a differential amplifier.

1 measuring input for polarized electrodes

1 measuring input for temperature sensor Pt100 or Pt1000

 

 

 

Measuring range

 

pH-value (Px)

0 ... ± 20:00

Voltage

0 ... ± 2000 mV

Current

0 ... ± 200.0 uA

Temperature

-150.0 ... + 450.0 ° C

 

Measurement error of the measuring instrument (without probe)

at 25 ° C and warm operating device

 

PH value

± 0.02

Voltage

± 2 mV

Temperature

≤ 0.2 ° C in the range of 0 ... + 100 ° C

 

as a function of ambient temperature

 

pH-value, voltage

Normally 40 uV / K

Temperature

00:04 ° C / K

 

 

 

Measurement amplifier

 

Input resistance

> 10 13 Ω

Offset current

<3 10-13 A

Offset voltage deviation as a function of ambient temperature

15 uV / K

 

 

Polarizer

 

Ipol

0 ... ± 127 uA

 

Upol

0 ... ± 1270 mV, in 10 mV steps

 

 

Dosage

 

Volume of Bürettenzylinders

1, 5, 10, 20 or 50 ml

Resolution

10 000 steps per buret cylinder

 

 

Materials

 

Housing

Polybutylene terephthalate (PBTP)

Keyboard Covers

Polycarbonate (PC)

 

 

Display

 

LCD, 2 lines of 24 characters

Character height 5 mm

 

 

RS232 interface

 

For printers and scales connection

or

Computer connection: completely controllable from external control unit

 

 

Conventional input / output lines

 

For sample changer, robot connection.

 

Input signals

Start, Stop, Enter, Clear, Sample Ready

Outputs

Ground state, Kondionierung ok, titration, the end of the titration, Error, activation, settable via RS232 control line

 

 

Analog Output

 

Output

-2000 ... 2000 mV

Signal at the analog output

Depending on your selection:

U (measured value)

dV / dt (measured value drift)

V (volume)

dV / dt (volume drift)

U (rel) (deviation with SET)

Resolution

1 mV (12 bit)

 

 

Ambient temperature

 

Nominal working range

5 ... 40 ° C

Storage, transport

-20 ... 70 ° C

 

 

Safety Specifications

 

Construction and testing in accordance with IEC publication 348, protection class I.

 

 

Mains connection

 

Voltage

100, 117, 220, 240 V ± 10% (changeable)

Frequency

50 ... 60 Hz

Input

15 VA

Fuse

Thermal fuse

 

 

Dimensions with Exchange Unit

 

Width

150 mm

Height

450 mm

Depth

275 mm

Weight, incl. Keypad

Approximately 3.4 kg

 

 

Product group: Titrators