Merck-Hitachi L-7485
Objektnummer | B00014591 |
---|---|
ID-number | 014591 |
Object name | Merck-Hitachi L-7485 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Merck-Hitachi
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Specifications
Photometric principle Ratio photometry; intensity of transmitted beam is monitored.
Light source 150 W xenon lamp
Excitation wavelength
setting range 200 to 850 nm, and zero order
Emission wavelength
setting range 250 to 900 nm, and zero order
Note that photomultiplier raust be changed at emission wavelengths greater than 731 nm.
Excitation side spectral
bandwidth: 15 nm
Emission side spectral
bandwidth 15,30 nm(variable)
Wavelength setting By keyboard or through
communication
Wavelength accuracy ±3 nm
Wavelength repeatability ±0.5 nm
Recorder output 10 mV full scale
Full scale range of 1 to 1000 is settable in increments of 1.
Processor output 1 V full scale; digital output of -40 (-40 mV) to 1000 (1000 mV) via D-line.
Response Changeable in 5 steps, corresponding to time constants of 0.1, 0.5, 2.0, 4.0, 8.0 seconds.
Sensitivity S/N ratio of 350 or higher with Raman spectrum of water (wavelength: 350 nm, time constant: 2.0 s)
Auto zero range 0 to 1000
Offset 0 to 1000 (settable in steps of 1)
Spectrum memory Up to 8 excitation or emission spectra can be stored.
Marker Marker output of approx. 0.6 mV at recorder terminal (corresponding to about 6 graduations on Chart)
Instrument parameter
setting Following parameters are settable and stored in battery-backed-up memory when power is turned off.
Full scale range
Spectrum measuring range
Photomultiplier applied voltalte
Offset value
Time program No. of programs 9
Settable time Up to 600 minutes in increments of 0.1 minute
No. of steps storable Up to 100 steps for a total of 9 files
Programmable items Excitation wavelength, emission wavelength, baseline processing
Display function 40 characters x 2 lines on backlighted LCD
Communication function D-line communication
External output terminals Analog output
For processor 1 V full scale
For recorder; 10 mV full scale
External I/0 contact
terminals Time program Start, error input/output, busy output (Above contacts are incorporated in Dline connector, and effective with analog connection.)
Auto zero input, marker input, lamp off input
Flow cell capacity Standard cell 12 µL (irradiated capacity)
Flow cell withstand pressure 2.9 MPa
Operating temperature range4 to 35 °C
Operating humidity range 45 to 80% RH (non-condensing)
Power requirement 100-115, 220-240 V AC, 50/60 Hz
Power consumption 420 VA
Dimensions 260 mm W x 500 mm D x 230 mm H
Weight Approx. 19 kg