Top Deal

Memmert HPP 1060

ID-number: 44057
Shipping: 10-14 working days
Status: Stock unit
€15,080.00
Excl. 19% VAT , excl. Shipping Cost
€17,945.20 incl. Tax
Description:
Memmert constant climate chamber HPP 1060.
Volume: 1060 L.
Setting temperature up to 70°C.
Timer with target time indication 1 min to 99 days.
Adjustable humidity range: 10-90% rh.
4x grids.
On castors.
230 V. 50/60 Hz. 1400 W.
More Information
Objektnummer B00044057
ID-number 44057
Object name Memmert HPP 1060
Year of construction 2020
Manufacture Memmert
Shipping 10-14 working days
Status Stock unit

Product group: KLIM

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

 

 

Memmert HPP 1060

The following illustrations and descriptions are model-specific and taken from brochures.

They do not represent the scope of delivery of the system.

Please refer to the offer text for the exact scope of delivery.

 

Technical data

temperature

Setting temperature range Without light, with humidity: +5 to +70 °C
Setting temperature range Without light, without humidity: 0 to +70 °C
Operating temperature range Without light, with humidity: +5 (at least 20 below room temperature) to +70 °C
Operating temperature range Without light, without humidity: 0 (at least 20 below room temperature) to +70 °C
Temperature setting accuracy 0.1 °C
temperature sensor 2 Pt100 sensors DIN class A in 4-wire measurement for mutual monitoring and function takeover in case of fault

Humidity

Humidity setting range 10 - 90% rh
Humidity Humidity supply with distilled water from an external container via a self-priming pump.
Humidification Humidification by hot steam generator
Dehumidification Dehumidification using a cold trap in Peltier technology
Humidity setting accuracy 0.5% rh

Control engineering

ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID microprocessor controller with 2 high-resolution TFT color graphic displays.
Language setting German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
adjustable parameters Temperature (Celsius or Fahrenheit), relative humidity, program duration, time zones, summer/winter time
timer Digital countdown timer with target time display, adjustable from 1 minute to 99 days
HeatBALANCE function Adjustment of the heating power distribution between the upper and lower heating groups from -50% to +50%
Function SetpointWAIT Process time only starts when the target temperature is reached.
Calibrate Three freely selectable values each for temperature and humidity

communication

interface Ethernet LAN, USB
Logging Saving the program sequence in case of power failure
programming Programming, managing and transferring programs via Ethernet interface or USB port using the AtmoCONTROL software

Security

Temperature monitoring Temperature selector (TWW), protection class 3.3 or temperature selector limiter (TWB), protection class 2, selectable on the display
AutoSAFETY Additionally integrated over- and under-temperature protection "ASF", which automatically follows the setpoint at freely selectable intervals, alarm if the temperature is exceeded or fallen below, switching off the heating function if the temperature is exceeded, switching off the cooling function if the temperature is fallen below.
Self-diagnostic system for troubleshooting temperature and humidity control
alarm visual and acoustic

Heating concept

Peltier Integrated, energy-saving Peltier heating/cooling system (heat pump principle) in the rear wall

Standard scope of delivery

Standard factory calibration certificate +25 °C / 60% rh, +40 °C / 75% rh, 5% CO 2 at +40 °C / 75% rh
door Fully insulated stainless steel doors with 2-point locking (compression door lock)
implementation Silicone grommet with an inner diameter of 18 mm, moisture-proof, sealable with a silicone plug, in the side wall, center left
Inserts 2 stainless steel grating(s), electropolished
Standard accessories Water canister including connecting hose

Stainless steel interior

Dimensions B (A) x H (B) x T (C) : 1040 x 1200 x 850 mm (T minus 32 mm for fan - Peltier)
volume 1,060.00 l
Maximum number of slots 14
Maximum load per device 200 kg
Max. load per slot 60 kg

Structural stainless steel housing

Dimensions W (D) x H (E) x D (F) : 1224 x 1720 x 1005 mm (D +56mm door handle & +111 mm Peltier element)
Lineup Mobile and lockable, on casters
Housing fully galvanized steel sheet back panel

Electrical data

Voltage Power consumption 230 V, 50/60 Hz
approx. 1400 W
Voltage Power consumption 115 V, 50/60 Hz
approx. 1400 W

Environmental conditions

Lineup The distance between the wall and the back of the device must be at least 15 cm. The distance to the ceiling must be at least 20 cm, and the lateral distance to the wall or to an adjacent device must be at least 5 cm.
Ambient temperature 16°C to 40°C
Humidity rh max. 70% non-condensing
Installation height max. 2000 m above sea level
Overvoltage category II
Pollution level 2

Packaging/Shipping Information

Transport information The devices must be transported in an upright position!
Statistical commodity code 8419 8998
Country of origin Federal Republic of Germany
WEEE Reg. No. DE 66812464
Dimensions including cardboard box W x H x D: 1370 x 1970 x 1300 mm
Net weight approx. 251 kg
Gross weight carton approx. 331 kg
 
Part of labexchange logo
Search engine powered by ElasticSuite