Memmert HPP 1060
Volume: 1060 L.
Setting temperature up to 70°C.
Timer with target time indication 1 min to 99 days.
Adjustable humidity range: 10-90% rh.
4x grids.
On castors.
230 V. 50/60 Hz. 1400 W.
| Objektnummer | B00044057 |
|---|---|
| ID-number | 44057 |
| Object name | Memmert HPP 1060 |
| Year of construction | 2020 |
| Manufacture | Memmert |
| Shipping | 10-14 working days |
| Status | Stock unit |
Product group: KLIM
-
Labexchange Klimaschrank FPG450-5% discount
until Dec 31, 2025 Special Price €6,080.00 Regular Price €6,400.00Excl. 19% VAT , excl. Shipping Cost
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Memmert HPP 1060
The following illustrations and descriptions are model-specific and taken from brochures.
They do not represent the scope of delivery of the system.
Please refer to the offer text for the exact scope of delivery.
Technical data
temperature
| Setting temperature range | Without light, with humidity: +5 to +70 °C |
|---|---|
| Setting temperature range | Without light, without humidity: 0 to +70 °C |
| Operating temperature range | Without light, with humidity: +5 (at least 20 below room temperature) to +70 °C |
| Operating temperature range | Without light, without humidity: 0 (at least 20 below room temperature) to +70 °C |
| Temperature setting accuracy | 0.1 °C |
| temperature sensor | 2 Pt100 sensors DIN class A in 4-wire measurement for mutual monitoring and function takeover in case of fault |
Humidity
| Humidity setting range | 10 - 90% rh |
|---|---|
| Humidity | Humidity supply with distilled water from an external container via a self-priming pump. |
| Humidification | Humidification by hot steam generator |
| Dehumidification | Dehumidification using a cold trap in Peltier technology |
| Humidity setting accuracy | 0.5% rh |
Control engineering
| ControlCOCKPIT | TwinDISPLAY. Adaptive multifunctional digital PID microprocessor controller with 2 high-resolution TFT color graphic displays. |
|---|---|
| Language setting | German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese |
| adjustable parameters | Temperature (Celsius or Fahrenheit), relative humidity, program duration, time zones, summer/winter time |
| timer | Digital countdown timer with target time display, adjustable from 1 minute to 99 days |
| HeatBALANCE function | Adjustment of the heating power distribution between the upper and lower heating groups from -50% to +50% |
| Function SetpointWAIT | Process time only starts when the target temperature is reached. |
| Calibrate | Three freely selectable values each for temperature and humidity |
communication
| interface | Ethernet LAN, USB |
|---|---|
| Logging | Saving the program sequence in case of power failure |
| programming | Programming, managing and transferring programs via Ethernet interface or USB port using the AtmoCONTROL software |
Security
| Temperature monitoring | Temperature selector (TWW), protection class 3.3 or temperature selector limiter (TWB), protection class 2, selectable on the display |
|---|---|
| AutoSAFETY | Additionally integrated over- and under-temperature protection "ASF", which automatically follows the setpoint at freely selectable intervals, alarm if the temperature is exceeded or fallen below, switching off the heating function if the temperature is exceeded, switching off the cooling function if the temperature is fallen below. |
| Self-diagnostic system | for troubleshooting temperature and humidity control |
| alarm | visual and acoustic |
Heating concept
| Peltier | Integrated, energy-saving Peltier heating/cooling system (heat pump principle) in the rear wall |
|---|
Standard scope of delivery
| Standard factory calibration certificate | +25 °C / 60% rh, +40 °C / 75% rh, 5% CO 2 at +40 °C / 75% rh |
|---|---|
| door | Fully insulated stainless steel doors with 2-point locking (compression door lock) |
| implementation | Silicone grommet with an inner diameter of 18 mm, moisture-proof, sealable with a silicone plug, in the side wall, center left |
| Inserts | 2 stainless steel grating(s), electropolished |
| Standard accessories | Water canister including connecting hose |
Stainless steel interior
| Dimensions | B (A) x H (B) x T (C) : 1040 x 1200 x 850 mm (T minus 32 mm for fan - Peltier) |
|---|---|
| volume | 1,060.00 l |
| Maximum number of slots | 14 |
| Maximum load per device | 200 kg |
| Max. load per slot | 60 kg |
Structural stainless steel housing
| Dimensions | W (D) x H (E) x D (F) : 1224 x 1720 x 1005 mm (D +56mm door handle & +111 mm Peltier element) |
|---|---|
| Lineup | Mobile and lockable, on casters |
| Housing | fully galvanized steel sheet back panel |
Electrical data
| Voltage Power consumption | 230 V, 50/60 Hz approx. 1400 W |
|---|---|
| Voltage Power consumption | 115 V, 50/60 Hz approx. 1400 W |
Environmental conditions
| Lineup | The distance between the wall and the back of the device must be at least 15 cm. The distance to the ceiling must be at least 20 cm, and the lateral distance to the wall or to an adjacent device must be at least 5 cm. |
|---|---|
| Ambient temperature | 16°C to 40°C |
| Humidity rh | max. 70% non-condensing |
| Installation height | max. 2000 m above sea level |
| Overvoltage category | II |
| Pollution level | 2 |
Packaging/Shipping Information
| Transport information | The devices must be transported in an upright position! |
|---|---|
| Statistical commodity code | 8419 8998 |
| Country of origin | Federal Republic of Germany |
| WEEE Reg. No. | DE 66812464 |
| Dimensions including cardboard box | W x H x D: 1370 x 1970 x 1300 mm |
| Net weight | approx. 251 kg |