Archive

Licor Odyssey

ID-number: 022731
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Licor Infrared imaging system Odyssey 9120. Software Odyssey 3.0. 200/240 V. 5 A. 50/60 Hz. YoC 2011. Demo unit
siehe Storeview
More Information
Objektnummer B00022731
ID-number 022731
Object name Licor Odyssey
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

 

manufacturer:      Li-Cor

model:                  Odyssey

 

 

 

The Odyssey lnfraredlmageris certified as a Class 1 laser product, containing a Class Illblaser. This means that hazardous laser radiation is not emitted outside the instrument. Radiation emitted inside the instrument is confined within protective housings and external covers. A series of safety interlocks ensures that the laser beam cannot escape during any phase of user operation.

 

The Odyssey lnfraredImaging System contains two lasers; one emitting at 785 nm, and one at 685 nm. Each has a peak power rating of 30 milliwatts. The 685 nm laser emits visible laser radiation —direct exposure to either beam may cause eye damage. Laser radiation is emitted through apertures at the top of the Odyssey microscope assembly. Because the microscope assembly moves in both planes relative to the glass scanning surface, laser radiation could be focused at any position on this surface.

 

 

Specifications

 

Laser/Microscope

Laser Lifetime:                                40,000 hours typical.

700 Channel Laser Source:            Solid-state diode raserat 685 nm.

800 Channel Laser Source:            Solid-state diode laser at 785 nm.

Detectors:                                     Silicon avalanche photodiodes.

Scanning Speed:                             6 minutes with 100µm resolution

Resolution:                                      20-500 pm.

Focusing Range:                             0-3.95 mm (suitable for most microplates with transparent, flat-bottom wells).

Operating Specifications

Operating Conditions:                     For Indoor use only; operating temperature 15-35 °C and dew point not greater than 20 °C, non-condensing; altitude not to exceed 2000m.

Environmental Conditions:              Pollution Degree 1.

Power Requirements:                     Switch edvoltage selection between 100-127 VAC and 200-240 VAC (voltage fluctuations not to exceed 10% of the nominal voltage);

                                                        47-63 Hz; 1.1 A at  120V typical; 2.25A at 120V maximum (270W).Insulation Category 11.

Dimensions                                   H x W x D: 36 x 45 x 55 cm.

Weight                                           24 kg

Data Storage Capacity:                   >25 GB.

Network Protocol:                            TCP/IP.

Network Connection:                       Cat. 5 RJ-45, 1013ase-T/100Base-TX.

 

 

Product group: Life science / Biotechnology