Leco FP-528
Objektnummer | B00014523 |
---|---|
ID-number | 014523 |
Object name | Leco FP-528 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Leco
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Description
The FP-528 is designed for smaller sample weights and is controlled by an external PC using Windows®-based operating software.
Features
Solid or liquid samples up to one gram
Minimal routine maintenance
Results in three minutes
How it Works
An encapsulated sample is placed into the loading head of the FP-528, where it is sealed and purged of any atmospheric gases that haue entered during sampling loading. The sample is then dropped into a hot furnace and flushed with pure Oxygen for very rapid combustion.
By-products of combustionCO 2 , H 2 0, N0 x , and N 2 pass through the furnace filter and thermoelectric cooler for subsequent collection in a ballast apparatus. These collected gases in the ballast are mixed, and a Small aliquot dose is then used for further conversion of the gases. The remaining aliquot that has been reduced is measured by the thermal conductivity cell for Nitrogen.
The System is controlled by an external PC using Windows'-based operating Software.
Specifications
Instrument Range @ 250 mg
3 cc Aliquot Loop: 160 ppm or 0.016% to 100% or 0.04 to 300 mg absolute
Nitrogen
Precision @ 250 mg
3 cc Aliquot Loop: 80 ppm or 0.5% RSD, whichever is greater
Readability 0.001%
Calibration Standard Sample; Linear
Analysis Time 3 minutes nominal
Sample Size Up to 250 mg
Detection Method Thermal Conductivity
Chemical Reagents Anhydrous Magnesium Perchlorate, Calcium Oxide, Sodium Hydroxide an an inert base, Copper Sticks, N Catolyst Reagent, Copper Turnings, Alumina Pellets, Magnesium Oxide
Gas Required
Carrier Gas: 99.99% Helium or Argon 40 ±4 psi (2.76 bars)
Combustion Gas: 99.99% Oxygen
40 ±4 psi (2.76 bars)
Pneumatic Gas: Compressed Air, source raust be oil and water free. 40 ±4 psi (2.76 bars)
Gas Flow Rates
Carrier Gas: Analysis: 200 mL/min (measure), 30 mL/min (reference) Conservation: 30 mL/min (measure), 30 mL/min (reference)
Combustion Gas: 1.3 to 6 L/min
(user programmable Oxygen profile)
Regulators
Helium: 0 to 125 psi, CGA 580,
15/16-14 Female R.H.
Oxygen: 0 to 125 psi, CGA 540,
7/8-14 Male R.H.
Air: 0 to 125 psi, CGA 346,
13/16-14 Male R.H.
Furnace Range Up to 975° Celsius
Weight
Determinator: 150 lb. (68 kg)
Physical Dimensions
Determinator: 28 in. H x 21 in. W x 23 in. D (71 cm x 53 cm x 58 cm)
Electrical Power Requirements
Determinator:
230 V (±10%), 50/60 Hz,
10A
Applications
Foods
Feeds
Forages
Fertilizers
Milled Products