Description:
Latronics NIR-Spectrometer LA-NIR 1700. Single beam. 800-1700 nm. Monochromator. InGaAs as Detector. Software. Cuvetteholder for 4 cuvettes 10 and 50mm. YoC 2006
Quotation
siehe Storeview
More Information
Objektnummer B00014585
ID-number 014585
Object name Latronics LA NIR 1700
Status Stock unit

Product group: NIR-Spectrometer

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                Latronics

Modell:              LA NIR 1700

Kommentar:      Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

NIR absorption spectroscopy is widely used for qualitative and quantitative analyses in areas such as metallurgy, geology, machine manufacturing, petrochemical industry, commodity inspection, medicine, environmental monitoring, food inspection, agricultural chemistry and teaching in colleges and universities etc..

Characteristic features:

•            Single beam wavelength scanning in a wavelength range of 900...1730 nm

•            Spectral resolution: 3 nm (2 nm an request)

•            Full Software controlled operation underWindows() (98SE, 2000, XP, Vista)

•            Customization of operating software an request

•            Synchronization with external devices by I/O signals

•            Wide sample compartment for Jong path length cells of up to 10cm

•            Various kinds of sample holder can be integrated

•            Dynamic range of absorbance A = 0...~ 2

Specifications:

Light Source                                          Tungsten lamp

Detector                                                 InGaAs -   photodiode

Wavelength range                                900   nm...1730 nm

Wavelength accuracy                           ± 0,5 nm

Wavelength reproducibility _                 ≤ 0,3 nm

Spectral bandwidth                                3 nm; others on request

Minimal wavelength increment             ~ 0,3 nm

Minimal sampling interval   (kinetics)    0,5 s (other minimal time an request)

Range of absorbance A                       0...2

Photometric accuracy                           ± 0,5   % T (T = transmission)

Photometric reproducibility                    ≤ 0,3 %   T

Baseline flatness                                   A= ± 0,01

Drift                                                        ≤ 0,004 A / h

                                                              (@ 1350 nm   after warm up)

Noise                                                     ≤ 0,4 % T ; peak to peak

                                                                (@1350 nm; duration of measurement: 3 min)

Ambient temperature                             10...~ 35 °C

Humidity                                                 <85%

Power supply                                         220 ± 10 % VAC, 50 Hz; < 50 W

Dimensions, weight                               487X388x185mm;   <20kg

Control                                                   Windows software (98SE, 2000, XP or Vista); Pentium3 processor or higher recommended

Special features                                    Communication with further devices by I/0 signals or RS232 an request; Adaptation of control software according to customers needs

Part of labexchange logo
Search engine powered by ElasticSuite