Archive

Labtoc TC, TOC

ID-number: 012940
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
siehe Storeview
More Information
Objektnummer B00012940
ID-number 012940
Object name Labtoc TC, TOC
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Labtoc

Modell:            TC, TOC

Kommentar:   Dokumente engl..

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

LABTOC is a fast, reliable and highly accurate system for the laboratory analysis of sample water.

Simple to use, LABTOC can be used by laboratory technicians with the minimum of training and still be relied upon to produce precisely accurate TOC and/or TC values from single or multiple samples with a range from 0-10 ppm to 0-4000 ppm.

LABTOC consists of an organics analyser, based on proven PPM PROTOC chemical technology , an auto-sampler capable of feeding between one and eighty eight separate samples to the analyser during a single run, and an lBM-compatible PC with exclusive, user-friendly software, which both controls the analytical process and monitors the results.

Competitively priced and highly flexible, LABTOC is ideal for applications where multiple
samples need to be taken from variety of areas or variable areas on a single site, or from a number .of sampling points on multiple sites for further analysis.

As such, it is suitable for use. by industry or by regulating authorities charged with monitoring widely divergent areas such as points along a river

LABTOC will also be of interest to Companies offering off-site sample analysis service to industry, water authorities in sewage receiving applications and environmental companies engaged in waste analysis and disposal contracts.

lncreasingly, the Total Organic Carbon content found in water streams is regarded as an excellent indication of water quality, and may protocols now specify TOC or TC analysis.

TOC testing can also compliment existing BOD or COD testing facilities, particularly if organics are of major importance in the analysis exercise.

LABTOC Systems can be custom-designed and built to customer’s own specifications and

software customised as required to meet more specialised requirements

FEATURES

•            User friendly Windows driven software

•            Provides TOC and/or TC analysis

•            Full on-screen and hard copy reporting

•            Range from 10 ppm to 4,000 ppm, fully adjustable

•            Multi-point calibration with 'Best Fit'curves

•            Print calc curve (with results)

•            Fully automatic QC diagnostic

•            Automatic re-calibration on failure

•            Multiple runs on each sample with SD, RSD and mean value

•            Automatic range adjustment for over ranging samples

•            Single and batch analysis (no syringe required)

•            Automatic shut off after batch analysis

•            No manual acidification of sample

PRINCIPLE Of OPERATION

The sample s continuously drawn in through the autosampler dip probe This is then joined by a continuous flow of acidified reactor fluid which - depending on the mode of operation - is either TC pumped directly to the injection valve, or TOC routed via an IC removal stage to the injection valve.

Once the .fresh sample has had time to flush out the injection valve it is switched by the PC for a precisely determined amount of time, diverting the flow of sample momentarily into the flow of fresh reagent which is being pumped constantly into the reactor

The organic carbon contained in the sample is then converted to CO 2 , by the UV light and the sodium persulphate. This is carried by a very constant flow of gas, firstly to a Gas Liquid Separator (GLS). The gas is finally dried by passing through a permeation dryer tube

CO 2 concentration is then measured by a solid state infrared detector which is tuned only for the detection of CO 2 . The output of the infrared is then fed back directly into the PC where the signal is measured and integrated to provide a precise measurement of TOC or TC, as required.

Control and Monitoring Options

The LABTOC analyser and auto-sampler units are controlled by an IBM – compatible PC. Data produced by the analyser is sent to the PC in turn, where it can be displayed graphically and automatically stored on floppy disk for later retrieval or as a permanent record of sample data.

The PC features PPM’s own exclusive Labmon TM Windows-driven software, providing a user friendly, clear and flexible means of controlling sampling and presenting sample data.

This data can then be displayed graphically and, if required, a hard copy can be made on a colour graphics printer.

Specifications

Analysis Models:

TC, TOC, TC and TOC

Sample Models:

Single sample Batch of up to 48/88 samples

Repeat Samplings:

From 1 to 3 runs (selectable)

Calibration:

Manual calibration, with choice of calibration curve.

Automatic calibration at start of batch.

QC calibration at selectable intervals during batch

Range:

Variable between 0-10 ppm to 0-4000 ppm

Detection limit:

1% of calibrated range

Linearity:

Better than 1% of calibrated range

Repeatability.

Within 2%

Analysis time:

Typically 6 minutes per sample

Data Handling:

By PC (manual supplied)

Records:

Results which are written to file and may be printed include calibration plots and tabular sample data. (On screen plot of measured concentration during run is no maintained)

Warm up time:

20 minutes from power on or stand-by

Analyser Output:

4-20 mA

Sampler Prep Time:

120 seconds

A/D base Address:

380 Seconds

Power:                        Voltage           Frequency

Analyser:                    240Vac            50 Hz

                                   110Vac            60Hz

Auto-Sampler:            240Vac            50Hz

                                   110Vac            60Hz

External Dimensions

Analyser:                    550mm H x 300mm W x 550mm D

Weight (approx):       25 kg

Auto-sampler:            560mm H x 660mm W x 710mm D

Weight:                       22 kg

Utilities Required

Gas:                             Nitrogen/Oxygen/Argon clean gas, ie. Dust and oil free to be supplied @ psi constant

Typical usage:           TC 180ml/min

                                               TOC 560 ml/min

Reagent

5 % sodium persulphate, 5% orthophosphoric acid in DI water

Typical consumption is 1ml/min

Options

IC Analysis:                            Allowing TOC by difference TC-IC = TOC

Low Level IR:            Permitting an analysis range of 0-100 ppb up to 0-40 ppm