Labexchange UV/VIS spectrophotometer FA560
Optics: two-beam system.
Wavelength Range: 190-1100nm
Spectral bandwidth: 1.8 nm.
Wavelength Accuracy: +/- 0.3nm
Display: 7 inch TFT LCD display, 480x480 pixels.
Measurement method: T, A, C, E
Light source: deuterium lamp and tungsten lamp.
Input: Keypad. Connection: USB-A for data and USB-B for PC.
With 4-fold cuvette holder.
Software included.

Optional: 8-fold sample changer. fixed sample holder.
micro cuvette holder. 10-100 mm cuvette holder.

new device. manufacturer warranty.
Add to Offer List
More Information
Objektnummer B00032096
ID-number 32096
Object name Labexchange FA560, UV-VIS Photometer,190-1100nm
Status Neugerät
Manufacture Labexchange
Shipping 3-4 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

 

manufacturer:      Labexchange

model:                  FA 560

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

 Technical data

 

Model FA560
FA560PC
FA580
FA580PC
FA590
FA590PC
Optical System Double Beam,Grating 1200 lines/mm
Wavelength 
Range
190-1100nm
Spectral 
Bandwidth
1.8nm 1nm 0.5,1,2,4,5nm
Wavelength 
Accuracy
±0.3nm
Wavelength 
Repeatability
≤0.2nm
Photometric
Accuracy
±0.002A(0-0.5Abs),
±0.004A
ï¼Âˆ0.5-1.0Abs),
±0.3%T
ï¼Âˆ0-100%Tï¼Â‰
Photometric
Repeatability
0.001Abs(0-0.5Abs)
0.002Abs(0.5-1.0Abs)
≤0.1%T
ï¼Âˆ0-100% T)
Stray Light ≤0.03%T@360nmï¼Â›220nm
Stability ±0.0003A/h@500nm
Baseline Flatness ±0.0005A
Noise 0.0002Abs
Display 65 thousand ture color 7 inch TFT LCD (480*480)
Photometric 
Mode
T,A,C,E
Photometric
Range
0-200%T,-0.301-3.0A
Detector Silicon Photodiode
Light
Source
Deuterium Lamp,Tungsten Lamp
Input Membrane Keypad
Output USB-A*2Print and data output USB-B Connect PC
Compartment Optional 8 Auto Cell holder,
Solid Sample Holder,Micro Cell Holder,
10-100mm Cell Holder