Archive

KNF 842.3

ID-number: 023484
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
KNF Neuberger Diaphragm vacuum pump Laboport 842.3 FT18. End vacuum <2 mbar. Max 34 L/min. 230 V. 50 Hz. 245 W. CE mark. YoC 2009.
siehe Storeview
More Information
Objektnummer B00023484
ID-number 023484
Object name KNF 842.3
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

xmlns:m="http://schemas.microsoft.com/office/2004/12/omml"

 

Firma:                  KNF

Modell:                 842.3

Kommentar:        Dokumente deut .

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

 

TECHNISCHE DATEN

 

 

 

 

 

Pneumatische Leistungen

 

Max. zulässiger

Betriebsüberdruck [bar ü]

1,0

 

Endvakuum [ mbar abs.]

< 2

 

Förderleistung bei atm . Druck [T/min]*

max. 34

 

Pneumatische Anschlüsse

 

Schlauchanschluss [mm]        I ID 10

 

Umgebungs- und Medientemperatur

 

Zulässige

Umgebungstemperatur

+ 5 °C bis + 40 °C

 

Zulässige Medientemperatur

+ 5 °C bis + 40 °C

 

Sonstige Parameter

 

Gewicht [kg]

13,4

 

Maße: LxHxB [mm]

341x 223x 167

 

Zulässige höchste relative Luftfeuchtigkeit der Umgebung

80 % für Temperaturen bis 31 °C, linear abnehmend bis 50 % bei 40 °C

 

Maximale Aufstellungshöhe [m ü. NN]

2000

 

Elektrische Parameter

 

Spannung [V]

100

115

230

 

Frequenz [Hz]

50/60

60

50

Maximale Stromaufnahme [A]

4,4

3,2

1,5

Leistungsaufnahme der Pumpe [W]

260

290

245

Maximal zulässige Netzspannungsschwankungen

+/- 10 %

+/- 10 %

+/- 10 %

Sicherung der Pumpe (je 2) T [A]

6,3

6,3

3,15

Schutzart Motor

IP44

 

 

5.2. Steuereinheit

 

Elektrische Parameter

 

Spannung [V]

100

115

230

 

Frequenz [Hz]

50/60

60

50

Leistungsaufnahme* [W]

270

300

295

Sicherung (je 2) T [A]

6,3

6,3

3,15

 

 

 

 

 

Product group: Vacuum pumps