Knauer 64
Objektnummer | B00015215 |
---|---|
ID-number | 015215 |
Object name | Knauer 64 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Knauer
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Speziell für den Einsatz in der HPLC entwickelte Kurzhubkolbenpumpe.
Verbindet die Einfachheit einer Einkolbenpumpe mit dem Vorteil der Pulsationsarmut einer überlappenden Doppelkolbenpumpe.
Die analytische HPLC Pump (0.1-9.9 mL/min) kann leicht und kostengünstig durch Austausch des Pumpenkopfes auf präparative (0.5-50 mL/ min) oder Mikro-HPLC (0.02-2 mL/min) umgerüstet werden.
Biokompatible Anwendung durch Titan-Pumpenkopf möglich.
Pulsationsarm, mit Kolbenhinterspülung, extern ansteuerbar.
Technische Daten
Fördervolumen a) mit analytischen Pumpenkopf 0,1-9,9 ml,/min, digital einstellbar in 99 Schritten von 0,1 ml/min an
b) mit präparativem Pumpenkopf 0,5-50 ml/min
c) mit Pumpenkopf für Micro-HPLC 0,02-2ml/min
Pulsation <1% bei Maximaldruck
Maximaldruck 40 MPa = 400 bar für analytischen Pumpenkopf und Pumpenkopf für Mikro-HPLC; 15 MPa = 150 bar für Präparativen Pumpenkopf
Druckmeßsystem Mikro-Bourdonrohr mit elektronischem Wandler zur Druckanzeige. Innenvolumen: ca. 20 ul
Druckanzeige Digitalanzeige an der Frontseite 0-40 MPa (0-400 bar), Nullpunkt nachstellbar, Schreiberbuchse auf der Rückseite der Pumpe für den Bereich 0-40 MPa. Zur Registrierung des Pumpendrucks wird ein Schreiber mit 100 mV für Vollausschlag benötigt.
Sicherheitsüberdruckabschaltung Stufenlos einstellbarer Grenzwert des Druckes. Bei Überschreiten des eingestellten Druckes schaltet die Pumpe ab. Die Abschaltung wird durch eine LED an der Frontseite angezeigt.
Sicherheitsunterdruckabschaltung Stufenlos einstellbarer Grenzwert des Druckes. Bei Unterschreiten des eingestellten Druckes schaltet die Pumpe nach ca. 1 Minute ab. Diese wird durch eine LED an der Frontseite angezeigt.
Elektronische Überlastabschaltung Bei elektrischer Überlastung des Pumpenmotors wird die Pumpe automatisch abgeschaltet. Die Abschaltung wird durch eine LED an der Frontseite angezeigt.
Externe Steuerung Start-Stop durch potentialfreien, externen Kontakt. Buchsen sind an der Rückseite des Gerätes dafür vorhanden. Stop durch externe Steuerung (Kontakt geschlossen) wird durch eine LED an der Frontseite angezeigt.
Flußsteuerung Durch externes Signal möglich. 1V=1ml/min
Eine Buchse dafür ist an der Rückseite des Gerätes vorhanden. Liegt an dieser Buchse kein Signal an, so fördert die Pumpe die an der Frontseite eingestellte Flußmenge. Liegt ein Signal größer als 30mV an der Buchse an, so übernimmt die Steuerung der Pumpendurchspannung die Steuerung des Pumpendurchflusses. Eine LED an der Frontseite zeigt die Flußsteuerung durch externes Signal an.
Materialien, die mit Flüssigkeit in Edelstahl, PTFE-Zusammensetzung, Saphir
Berührung kommen bzw. Keramik, Rubin
Abmessungen 240 x 140 x 310 mm
Gewicht ca. 5,2 kg
Spannungsversorgung 100-120 V/200-240 V, 50-60 Hz, 30 VA
Sicherungen 2 x 1A, träge, DIN 41662
Dieses Gerät ist gemäß DIN 57411 Teil 1 und VDE 0411 Teil 1 Schutzmaßnahmen für elektronische Meßgeräte gebaut und.