Archive

Julabo V3

ID-number: 014487
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Julabo Bath circulator V3. Up to 140°C. 2,1 KW. Class 2.
siehe Storeview
More Information
Objektnummer B00014487
ID-number 014487
Object name Julabo V3
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                Julabo

Modell:              V3

Kommentar:      Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.



P R E S E N T A T I 0 N

JULABO Immersion Circulators of the "V" model range presented herein are suitable for liquid temperature application to bath tanks Of preferred size with a bath liquid capacity not exceeding 50 ltr. capacity. The Immersion Circulator is attached to bath tanks with a bath attachment clamp supplied.

The Immersion Circulator "V" features versatility in appli­cation, technical advantages, high operating comfort and safety installations. This instrument can be fitted with pump connections (refer to accessories - 9.') for external temperature application tasks.

The electronic proportional temperature control adapts the heating energy supply to the hegt requirement in the Cir­culator bath, thus ensuring rapid hegt-up and high tempera­ture constancy and bath liquid uniformity.

JULABO Immersion Circulators of the "V" model range are built to the requirements for electrically operated laboratory in­struments of DIN 57 789 and VDE 0789 Part 200 as well as the safety requirements of DIN 12 879 (German Industrial Norm).

Safety classification "2" permits unattended instrument Ope­ration with inflammable bath liquids.


T E C H N I C A L   D A T A S   P E C I F I C A T I 0 N S

Technical specifications

to DIN 58 966                                                           V

Working temperature range                °C                  22 ... 150

Operating temperature range             °C                  -20 ... 150

Characteristic temperature                 °C                  22

Temperature selection                                             analog

Fine trimming                                      °C                  + 2

Fixed-point temperatures                    °C                  25 / 30 / 37

Temperature control System                                   proportional

Regulator Sensor                                                     PTC

Temperature control accuracy          °C                  +0,02

Variation under load                            °C/w              2 x 10 -3

Ambient temperature changes           %                   1

Mains voltage fluctuations                   °C/%              2 x 10 -3

Heater capacity                                   w                    2000

RFI suppression                                                       Std.
SAFETY FEATURES:

Variably adjustable excess

temperature protection                       °C                  20 ... 170

Low liquid level protection                                        float switch

DIN 12 879 safety classification                               2

Pump capacity

Pressure pump: max. pressure        mbar              240

max. Output                                        ltr./min.          10

Specific cooling water flow                 ml/min.          60
(carrier = cooling coil)

Total power consumption                   w                    2050

Mains power connection                     V/Hz               220 - 240 / 50

Product group: Water baths