Jenway 6280
| Objektnummer | B00021324 |
|---|---|
| ID-number | 021324 |
| Object name | Jenway 6280 |
| Status | Stock unit |
Product group: Photometers / Spectrophotometers
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
model: 6280
annotation: Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

6280 fluorimeter 190-650nm
- High sensitivity photomultiplier detector
- Wavelength range 190 - 650nm
- Raw fluorescence and concentration display
- Kinetic (timed readings) function
The high sensitivity of fluorimetric measurement techniques enables trace levels to be determined in a broad range of samples. Selectivity is also enhanced enabling interference free analysis of even the most complex sample matrix.
All models in the 62 Series enable simple raw fluorescence measurements to be made without the need to calibrate. These comparative fluorescence levels can be used as a basic indicator or for method evaluation procedures.
Precise concentration measurements can be made by calibration with a blank and standard solution. Where expected sample concentrations may cover a wide range a calibration curve can be created, using up to six standards.
Twenty methods can be created and saved with both a numeric ID as well as an alphanumeric name. By entering the excitation and emission wavelengths in the method the filter characteristics and positions are automatically verified before measurements are made.
The model 6280 is ideal for a broad range of applications in food and beverage analysis, including Histamine, Quinine, Aflatoxins and Vitamins. It also has a broad range of uses in Biochemistry and Life Science analysis with measurement of parameters such as DNA/RNA, Protein, Steroids, Enzymes and Drugs. For water and environmental analysis it has applications for Dye Tracing (Flow Measurement), Cyanobacteria and Ammonium measurement amongst many others.
Technical Specifications
Model
6280
Light source
Pulsed xenon lamp with press-to-read operation
Expected Lifetime
No replacement required in normal operation
Sensitivity (Quinine Sulphate)
<1ng/ml
Dynamic range
5.2 x 10 6
Detector
Photomultiplier
Wavelength range
190 to 650nm
Wavelength selection
Intelligent Filter Modules (IFM)
Raw Fluorescence
Yes
Concentration
Yes
Calibration
Blank + up to 6 standards
Kinetics (timed readings)
In both above modes
Time limits
1 reading every 3 to 999 seconds
Methods stored
20
Results stored
100/method
GLP
Method lock with password access
Time and date stamped results
Last calibration date and time stored
Calibration interval set
Calibration due reminder
User ID
Outputs
RS232
PC software
Compatible with DataWay (option)
Sample handling
10mm square cuvette holder (standard)
Heated sample holder (option)
Yes
Sipper Pump (option)
Yes
Power supply
100 to 240Vac universal mains adapter
12Vdc input (cigarette lighter cable and battery pack options)
Size
365 (w) x 272 (d) x 160 (h) mm
Weight
6Kgs
Sipper Pump
Modes:
Continuous Aspiration Flow rate dependent on tube ID.
12ml/min with supplied tube
Timed aspiration sample/air-gap/wash.
sample volumes 75µl min / 9.5ml max
segment run time 48 secs max
Memory Non-volatile
Power Supply 115 or 230V
Size 205 (w) x 190 (d) x 160 (h) mm
Weight 1.5Kgs
Heated Cell Block / Controller
Temperature:
Range Ambient +2°C to 60°C
Resolution 0.1°C
Regulation ±0.1°C
Accuracy ±0.5°C
Control System PID
Power Supply 100 230Vac
Size 205 (w) x 165 (d) x 85 (h) mm
Weight 870g (Controller) 405g (Block)