Description:
IL Coagulometer ACL Advance. YoC: 2001.
siehe Storeview
More Information
Objektnummer B00013539
ID-number 013539
Object name IL ACL Advance
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       IL

model :                   ACL Advance

annotation :           Dokumente engl.

 

 

ACL ADVANCE

 

Easy-to-use hemostasis testing analyzer with the flexibility you need

The ACL Advance is a versatile fully automated analyzer with the comprehensive test menu and convenience you expect from the ACL line. With continuous loading and onboard capacity of 264 cuvettes/120 samples, it’s a flexible, time saving solution for varying workloads.

§                Comprehensive routine and specialty assay menu

§                Random access testing

§                STAT samples for loading at any time, in any position

§                Automated factor parallelism testing

§                Walk-away and automatic rerun capabilities

§                Results auto-validation program

 

Specifications

Turbidimetric (clotting) channel;                    YES

8 infrared LED at 880 nm (λ)

Absorbance (chromogenic and immunological

assays ) channel;                                           YES

8 LEDs at 405 nm (λ)

lmmunological Tests (D-Dimer, vWF

and Free Protein S                                         YES

Samples on-board (maximum)                     120

Reagents on-board (maximum)                    34+8 (additional)

Cuvettes on-board (maximum)                     264 (33 strips of 8 each)

Sample Predilution                                         YES

Calibration Curve Predilution                         YES

STAT Capability                                             YES

Quality Control                                               YES

Patient Data Storage                                    YES (minimum 100000 results)

Reaction Curves Availability                          YES (minimum 10000 Curves)

Liquid (sample/reagent) Sensors                  YES

Rinne and Liquid Waste Sensors                  YES

Primary Tubes Capability                              YES

Bar Code Reader         Internal (on-board)     YES

Throughput                   PT/hour                      Up to 240

                        APTT/hour                  Up to 180

Automatic Downloading and Uploading         YES

Automatic Validation (Configurable Criteria) YES

Automatic Save of Reaction Curves for

Validated Samples                                         YES

Automatic Printing                                          YES

Automatic Rerun/Reflex Testing                    YES

Factor Parallehm                                           YES

Open Configurable Cycles                            YES

Bidirectional Interface                                    YES (ASTM protocol)

Personal Computer Characteristics              Pentium 2 GHz

(Minimum Requirements)                              40 GB (HD)

                                                          256 MB RAM

                                                          LCD monitor (flat screen)

External Printer (Optional)                             80 columns

                                                          (IBM Pro Printer emulation protocol)

 