IKA Mill A 10. NEW. Original packed.
siehe Storeview
More Information
Objektnummer B00014258
ID-number 014258
Object name IKA A 10
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                IKA

Modell:              A 10

Kommentar:      Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

IKA A 10

Description

A 10 The device consists of a drive unit with grinding chamber an cover. the are connected to each other by means of quick-release locks. When assemling the two units make certain that the safety pin in the drive unit is pushed down by the pressure pin on the cover. Otherwise, a tight and reliable connection is not ensured, the yellow error lamp will light up and the grinder will not Start.

The device is started by pressing the push-button at the front.

Grinding

Fineness is mainly dependent on how long the grinding Operation is performed.

Dry, brittle materials are easily ground, but may not be larger than the size of a pea as there may be langer of damage when carbide metal beaters are used. The A14 stainiess steel beater is assembled from rust- and acid-proof stell (materialno. 1,4034). The A15 carbide metal beater male of carbide metal (86%tungsten carbide and 14% cobalt) is available if particulary wear-resistant material is required, The Al 7 star-type blade (material no. 1.4310) is available for specifi­cally light ground materials such as pharmaceuticals, tablets, card­board, fett, polystyrene, plastic foams (Brittle) and the like

The A18 grinding chamber reduction element (included in the deli­very quantity) is inserted into the grinding chamber for comminution of small sample quantities (1-5m1) and specifically lighter products.

Grinding while cooling

Plastic, soft or smeary materials haue to be cooled if they are to be ground.

There are two hose couplings located at the rear of the grinder in order to connect the cooling brise. cooling with tap water is usual­ly sufficient for substances which become hat as a result of the grinding operation and are thus given to smearing or Chose that pro­duce oil.

The grinding chamber may only be filled halfway especially when drugs containing oils and similar materials are ground.

If more refrigeration is required then the ground matter should be cooled prior to being put into the grinding chamber.

The followiung procedure shall apply if liquid nitrogen is used in order to embrittle the material to be ground:

Safety Information:

Suitable protective gloves must be worn when filling and transferring liquid nitrogen!

Protective glasses must be worn!

-    The sample to be ground is put into a suitable vessel (e.g. evapo­rating dish) and covered with enough liquidnitrogen until it is com­pletely covered.

       When using liquid nitrogen make certain that the sample is not capable of reacting with Oxygen.

-    Cool grinding chamber using liquid nitrogen.

-    Put the deep-cooled sample into the grinder and grind approxima­tely 15 seconds.

-    Then open the grinder and add liquid nitrogen for only as lang as it takes for the sample to become deep-cooled again (embrittled),

Safety Information:

Make certain that the liquid nitrogen has evaporated befo­re beginning the grinding operation.

NOTE: Danger of overpressure!

-     Repeat the grinding operation for approximately 15 seconds.

-     Repeat the sequence of cooling and grinding until desired finen­ess has been achieved.

-     If the required fineness has not been achieved alter 5 minutes, then a further reduction in grain size is unlikely.

The respective grinding chambers are sealed by means of labyrinth sealings. Though they are dust-proof, they are not leak-proof, This should be taken into account for substances where liquids may escape.

Technical data

Design voltage:                                   VAC          230±10%

                                                    or     VAC          115±10%

Deign frequency:                                 Hz             50/60

Permissible ambient temperature:    °C             +5 bis +40

Permissible relative humidity:             %              80

Degree of protction

                             as in DIN 40 050:                    IP 21

Rated Speed:                                      1/min        20 000

Motor:                                                                   universal motor

A 10

Maximum motor input:                        W              180

Ginding chamber useful volume:        ml              50

Permissible operating time

                            (without cooling):    min            5

Interference supperssion:                                   as in VDE 0871

Dimensions:                                        mm           120 x 105 x 225

Weight:                                                kg              2,2

Associated standards and regulations

Associated EU guidelines

EMC guideline: 89/336/EWG, 93/31/EWG

Low voltage guideline: 73/023/EWG

Machine-guideline: 89/392/EWG, 93144/EWG, 93/68/EWG

Construction in accordance with the following safety standards EN 61 010-1

EN 292-1, -2    EN 414

UL 3101-1        CAN/CSA C22,2 (1010-1)

Construction in accordance with the following EMV standards EN 55 014-1

EN 50 081        EN 50 082-1

Accessories optional

A 10

A 18      grinding chamber reduction element

A 11      cover

A 14      spare beater, stainless steel

A 15      beater, carbide metal

A 17      Star-type blade, stainless steel

Product group: Mills / Crushers