Archive

Idaho 2380

ID-number: 013877
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Idaho PCR-Thermal cycler Rapidcycler 2380. YoC 1995.
siehe Storeview
More Information
Objektnummer B00013877
ID-number 013877
Object name Idaho 2380
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Idaho

Modell:            2380

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

The Rapidcyclerm is a rapid tempeeture cycling system based an heat transfer by hot air to samples contained in thin capillary tubes. For most reactions, products can easily be visualized with ethidium bromide an agarose gels after a total reaction time of 15-30 minutes. The rapid temperature response of this instru­ment can improve product specificity significantly while decreasing the required reaction time by up to an order of magnitude.

Average temperature transition rotes in most instruments are commonly about 1° C/sec when metal blocks or water are used for thermal equilibration and samples are contained in plastic microfuge tubes. A significantfraction of the cycle time isspent heating and cooling the sample, as opposed to being spent at optimal temperatures. Long reaction times of 2-6 hours are com­mon, and slow transition rotes make it difficult to deter­mine optimal temperatures and times for each stage of the cyclic reactions. Instantaneoustemperature changes are notpossible because of sample, container and cycler heat capacities, "Second generation" instru m entation can complete 30-cycles in about one hour. lt is unlikely any instrument based an samples contained in conical tubes with heating and cooling through a metal block can achieve faster cycles at any price. However, with capillary tubes and air heating, transition Tates of 5-10°C/ sec are easily obtained. Complete 30-cycle reactions can be finished in os little as 10 min. Biochemical reactions are fast. The Rapidcycler is the first instrument engineered to match this speed.

The advantages of an air-cycling system include simplicity, low cost, and rapid temperature cycling. Air is an ideal heat transfer medium which can change tem­perature quickly because of its low density. Temperature homogeneity problems are solved by rapidly mixing air with a fan to provide homogeneous temperature expo­sure over the sample containers, The sample container is just os important os the heat transfer medium. An optimal sample container should be water-vaportight and have:

(i) low thermal mass,

(ii) good thermal conductivity,

(iii) minimal internal condensation,

(iv) easy sample recovery without cross contamination,

(v) No adverse effects an the reaction.

Whatever the containermaterial, temperatureequilibra­tion will always be achieved faster if the sample volume is small, if the container wall is thin, and if the surface-to­volume ratio of the sample exposed to the container wall is high. Problems with condensation can be reduced by minimizing the free air space surrounding the sample.

vicrofuge tubes are kept water-vapor tight by mechanical closure and, if necessary, overlaid mineral oil. Thermal conductivity is poor because of the material and its thickness (about 1 mm). Internal condensation can occur if mineral oil is not used and particularly if different parts of the tube are at different temperatures.

Sample mixing by convection has been used in conical tube Instruments, The temperature gradients that cause convection are not a good Idea for a temperature­dependent reactions

Capillary tubes are kept vaportight by flame clo­sure of the ends, They conduct heat to the sample better than microfuge tubes because of decreased wall thickness (ca. 0.2 mm) and a better surface-to-volume ratio. Dead air space is minimized to prevent significant condensation, Different volumes of a sample can be placed in the same diameter capillary tube so that rapid heattransfer is maintained,

After amplification, the ends of the glass capillaries can be quickly scored with a fite and snapped off with less risk of aerosolization and contamination than microcentrifuge tubes. The capillary tubes nerve both os a transfer pipette and a container for temperature cy­cling, The reaction product, already containing Ficoll and an electrophoresis indicator dye, can be directly emptied into a gel well without exposureto an intermedi­ate pipette tip or to extraction procedures.

Decreasing the hegt capacity of the cycling sys­tem can markedly decrease the total time required for reactions that require temperature cycling, In addition, air cycling and miniaturization can significantly decrease the costs of reagents and the personnel time required to optimize reactions,

Product group: PCR

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure